Rockwell Automation/Allen-Bradley1756-EN2T4325481 Rockwell Automation/Allen-BradleyPowerFlex 525-EENET3615.1.1.458200PF525_A115201<DataTypes><DataType Name="AB:PowerFlex525V_E_142E84CE:I:0" Class="IO"><Members><Member Name="pad" DataType="DINT" Hidden="1" /><Member Name="DriveStatus" DataType="INT" Radix="Binary" /><Member Name="Ready" DataType="BIT" BitNumber="0" Target="DriveStatus"></Member><Member Name="Active" DataType="BIT" BitNumber="1" Target="DriveStatus"></Member><Member Name="CommandDir" DataType="BIT" BitNumber="2" Target="DriveStatus"></Member><Member Name="ActualDir" DataType="BIT" BitNumber="3" Target="DriveStatus"></Member><Member Name="Accelerating" DataType="BIT" BitNumber="4" Target="DriveStatus"></Member><Member Name="Decelerating" DataType="BIT" BitNumber="5" Target="DriveStatus"></Member><Member Name="Faulted" DataType="BIT" BitNumber="7" Target="DriveStatus"></Member><Member Name="AtReference" DataType="BIT" BitNumber="8" Target="DriveStatus"></Member><Member Name="CommFreqCnt" DataType="BIT" BitNumber="9" Target="DriveStatus"></Member><Member Name="CommLogicCnt" DataType="BIT" BitNumber="10" Target="DriveStatus"></Member><Member Name="ParmsLocked" DataType="BIT" BitNumber="11" Target="DriveStatus"></Member><Member Name="DigIn1Active" DataType="BIT" BitNumber="12" Target="DriveStatus"></Member><Member Name="DigIn2Active" DataType="BIT" BitNumber="13" Target="DriveStatus"></Member><Member Name="DigIn3Active" DataType="BIT" BitNumber="14" Target="DriveStatus"></Member><Member Name="DigIn4Active" DataType="BIT" BitNumber="15" Target="DriveStatus"></Member><Member Name="OutputFreq" DataType="INT" Radix="Decimal" /><Member Name="Fault1Code" DataType="INT" Radix="Decimal" /><Member Name="DriveStatus_param" DataType="INT" Radix="Binary" /><Member Name="DriveStatus_param_Running" DataType="BIT" BitNumber="0" Target="DriveStatus_param"></Member><Member Name="DriveStatus_param_Forward" DataType="BIT" BitNumber="1" Target="DriveStatus_param"></Member><Member Name="DriveStatus_param_Accelerating" DataType="BIT" BitNumber="2" Target="DriveStatus_param"></Member><Member Name="DriveStatus_param_Decelerating" DataType="BIT" BitNumber="3" Target="DriveStatus_param"></Member><Member Name="DriveStatus_param_SafetyActive" DataType="BIT" BitNumber="4" Target="DriveStatus_param"></Member><Member Name="OutputCurrent" DataType="INT" Radix="Decimal" /><Member Name="OutputVoltage" DataType="INT" Radix="Decimal" /></Members></DataType></DataTypes> — Lost Communication”, places it in MCM.CMD.Log, and increments MCM.CMD.Log_Quantity. If the same line later appears in MCM.STS.Acknowledge_Log, the routine latches Acknowledge and clears the entry so the log stays current. The command bit MCM.STS.Unacknowledge_All_Logs resets the Acknowledge latch, guaranteeing that the next loss of communication will produce a fresh message. Command bits The routine receives Communication_Fault from its own port monitor. The routine receives EN4TR_Communication_Fault from the rack adapter. The routine receives MCM.STS.Unacknowledge_All_Logs to clear the acknowledge latch. Status bits The routine sets Communication_Faulted when either link is down. The routine sets CTRL.STS.Communication_Faulted with the same value. HMI bits The HMI displays HMI.STATE as 0 for healthy and 1 for faulted. The HMI raises HMI.Alarm.Communication_Faulted only while Communication_Faulted is true and EN4TR_Communication_Fault is false. Alarm bits The system raises HMI.Alarm.Communication_Faulted whenever the switch itself loses communication and the EN4TR adapter is still online. ]]>