@ -0,0 +1,133 @@
<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<RSLogix5000Content SchemaRevision="1.0" SoftwareRevision="36.00" TargetName="AOI_PMM" TargetType="AddOnInstructionDefinition" TargetRevision="1.0 " TargetLastEdited="2025-07-15T12:16:40.504Z" ContainsContext="true" ExportDate="Tue Jul 15 16:36:23 2025" ExportOptions="References NoRawData L5KData DecoratedData Context Dependencies ForceProtectedEncoding AllProjDocTrans">
<Controller Use="Context" Name="BaseProgram">
<DataTypes Use="Context">
<DataType Name="UDT_ALARMS_PMM" Family="NoFamily" Class="User">
<Members>
<Member Name="ZZZZZZZZZZUDT_ALARMS0" DataType="SINT" Dimension="0" Radix="Decimal" Hidden="true" ExternalAccess="Read/Write"/>
<Member Name="PMM_Communication_Fault" DataType="BIT" Dimension="0" Radix="Decimal" Hidden="false" Target="ZZZZZZZZZZUDT_ALARMS0" BitNumber="0" ExternalAccess="Read/Write">
<Description>
<![CDATA[PMM Communication Fault]]>
</Description>
</Member>
</Members>
</DataType>
<DataType Name="UDT_HMI_PMM" Family="NoFamily" Class="User">
<Members>
<Member Name="STATE" DataType="DINT" Dimension="0" Radix="Decimal" Hidden="false" ExternalAccess="Read/Write"/>
<Member Name="PMM_Total_Power" DataType="REAL" Dimension="0" Radix="Float" Hidden="false" ExternalAccess="Read/Write">
<Description>
<![CDATA[Current total real power usage in kilowatts (kW)]]>
</Description>
</Member>
<Member Name="PMM_KWH_Consumed" DataType="REAL" Dimension="0" Radix="Float" Hidden="false" ExternalAccess="Read/Write">
<Description>
<![CDATA[Total energy consumed over time in kilowatt-hours (kWh)]]>
</Description>
</Member>
<Member Name="PMM_Max_Total_Power" DataType="REAL" Dimension="0" Radix="Float" Hidden="false" ExternalAccess="Read/Write">
<Description>
<![CDATA[Highest recorded real power usage in kilowatts (kW)]]>
</Description>
</Member>
<Member Name="Alarm" DataType="UDT_ALARMS_PMM" Dimension="0" Radix="NullType" Hidden="false" ExternalAccess="Read/Write"/>
</Members>
<Dependencies>
<Dependency Type="DataType" Name="UDT_ALARMS_PMM"/>
</Dependencies>
</DataType>
</DataTypes>
<AddOnInstructionDefinitions Use="Context">
<AddOnInstructionDefinition Use="Target" Name="AOI_PMM" Revision="1.0" ExecutePrescan="false" ExecutePostscan="false" ExecuteEnableInFalse="false" CreatedDate="2025-07-15T11:44:04.434Z" CreatedBy="LCIBATUMI\guga.kakhadze" EditedDate="2025-07-15T12:16:40.504Z" EditedBy="LCIBATUMI\guga.kakhadze" SoftwareRevision="v36.00"
>
<Parameters>
<Parameter Name="EnableIn" TagType="Base" DataType="BOOL" Usage="Input" Radix="Decimal" Required="false" Visible="false" ExternalAccess="Read Only">
<Description>
<![CDATA[Enable Input - System Defined Parameter]]>
</Description>
</Parameter>
<Parameter Name="EnableOut" TagType="Base" DataType="BOOL" Usage="Output" Radix="Decimal" Required="false" Visible="false" ExternalAccess="Read Only">
<Description>
<![CDATA[Enable Output - System Defined Parameter]]>
</Description>
</Parameter>
<Parameter Name="PMM_Input1" TagType="Base" DataType="AB:1420_V2_ENT_BC244CBD:I:0" Usage="InOut" Required="true" Visible="true" Constant="false"/>
<Parameter Name="PMM_Input2" TagType="Base" DataType="AB:1420_V2_ENT_A691F258:I:0" Usage="InOut" Required="true" Visible="true" Constant="false"/>
<Parameter Name="PMM_Input3" TagType="Base" DataType="AB:1420_V2_ENT_BC1E731C:I:0" Usage="InOut" Required="true" Visible="true" Constant="false"/>
<Parameter Name="PMM_Input4" TagType="Base" DataType="AB:1420_V2_ENT_922708DF:I:0" Usage="InOut" Required="true" Visible="true" Constant="false"/>
</Parameters>
<LocalTags>
<LocalTag Name="HMI" DataType="UDT_HMI_PMM" ExternalAccess="None">
<DefaultData Format="L5K">
<![CDATA[[0,0.00000000e+000,0.00000000e+000,0.00000000e+000,[0]]]]>
</DefaultData>
<DefaultData Format="Decorated">
<Structure DataType="UDT_HMI_PMM">
<DataValueMember Name="STATE" DataType="DINT" Radix="Decimal" Value="0"/>
<DataValueMember Name="PMM_Total_Power" DataType="REAL" Radix="Float" Value="0.0"/>
<DataValueMember Name="PMM_KWH_Consumed" DataType="REAL" Radix="Float" Value="0.0"/>
<DataValueMember Name="PMM_Max_Total_Power" DataType="REAL" Radix="Float" Value="0.0"/>
<StructureMember Name="Alarm" DataType="UDT_ALARMS_PMM">
<DataValueMember Name="PMM_Communication_Fault" DataType="BOOL" Value="0"/>
</StructureMember>
</Structure>
</DefaultData>
</LocalTag>
<LocalTag Name="Communication_Fault" DataType="BOOL" Radix="Decimal" ExternalAccess="None">
<Description>
<![CDATA[Communication Faulted]]>
</Description>
<DefaultData Format="L5K">
<![CDATA[0]]>
</DefaultData>
<DefaultData Format="Decorated">
<DataValue DataType="BOOL" Radix="Decimal" Value="0"/>
</DefaultData>
</LocalTag>
</LocalTags>
<Routines>
<Routine Name="Logic" Type="RLL">
<RLLContent>
<Rung Number="0" Type="N">
<Text>
<![CDATA[XIC(PMM_Input1.ConnectionFaulted)OTE(Communication_Fault);]]>
</Text>
</Rung>
<Rung Number="1" Type="N">
<Text>
<![CDATA[MOVE(PMM_Input2.TotalRealPower,HMI.PMM_Total_Power)MOVE(PMM_Input3.kWhConsumed,HMI.PMM_KWH_Consumed)MOVE(PMM_Input4.MaxTotalRealPwr,HMI.PMM_Max_Total_Power);]]>
</Text>
</Rung>
<Rung Number="2" Type="N">
<Comment>
<![CDATA[Running
]]>
</Comment>
<Text>
<![CDATA[XIO(Communication_Fault)MOVE(0,HMI.STATE);]]>
</Text>
</Rung>
<Rung Number="3" Type="N">
<Comment>
<![CDATA[Communication Faulted
]]>
</Comment>
<Text>
<![CDATA[XIC(Communication_Fault)MOVE(1,HMI.STATE);]]>
</Text>
</Rung>
<Rung Number="4" Type="N">
<Text>
<![CDATA[XIC(Communication_Fault)OTE(HMI.Alarm.PMM_Communication_Fault);]]>
</Text>
</Rung>
</RLLContent>
</Routine>
</Routines>
<Dependencies>
<Dependency Type="DataType" Name="UDT_HMI_PMM"/>
</Dependencies>
</AddOnInstructionDefinition>
</AddOnInstructionDefinitions>
</Controller>
</RSLogix5000Content>

File diff suppressed because it is too large Load Diff

File diff suppressed because it is too large Load Diff

View File

@ -0,0 +1,142 @@
<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<RSLogix5000Content SchemaRevision="1.0" SoftwareRevision="36.00" TargetName="UDT_ALARMS_PMM" TargetType="DataType" ContainsContext="true" ExportDate="Tue Jul 15 16:36:45 2025" ExportOptions="References NoRawData L5KData DecoratedData Context Dependencies ForceProtectedEncoding AllProjDocTrans">
<Controller Use="Context" Name="BaseProgram">
<DataTypes Use="Context">
<DataType Use="Target" Name="UDT_ALARMS_PMM" Family="NoFamily" Class="User">
<Members>
<Member Name="ZZZZZZZZZZUDT_ALARMS0" DataType="SINT" Dimension="0" Radix="Decimal" Hidden="true" ExternalAccess="Read/Write"/>
<Member Name="PMM_Communication_Fault" DataType="BIT" Dimension="0" Radix="Decimal" Hidden="false" Target="ZZZZZZZZZZUDT_ALARMS0" BitNumber="0" ExternalAccess="Read/Write">
<Description>
<![CDATA[PMM Communication Fault]]>
</Description>
</Member>
</Members>
</DataType>
<DataType Use="Target" Name="UDT_AOI_PMM" Family="NoFamily" Class="User">
<Members>
<Member Name="AOI" DataType="AOI_PMM" Dimension="0" Radix="NullType" Hidden="false" ExternalAccess="Read/Write"/>
<Member Name="HMI" DataType="UDT_HMI_PMM" Dimension="0" Radix="NullType" Hidden="false" ExternalAccess="Read/Write"/>
</Members>
<Dependencies>
<Dependency Type="AddOnInstructionDefinition" Name="AOI_PMM"/>
<Dependency Type="DataType" Name="UDT_HMI_PMM"/>
</Dependencies>
</DataType>
<DataType Use="Target" Name="UDT_HMI_PMM" Family="NoFamily" Class="User">
<Members>
<Member Name="STATE" DataType="DINT" Dimension="0" Radix="Decimal" Hidden="false" ExternalAccess="Read/Write"/>
<Member Name="PMM_Total_Power" DataType="REAL" Dimension="0" Radix="Float" Hidden="false" ExternalAccess="Read/Write">
<Description>
<![CDATA[Current total real power usage in kilowatts (kW)]]>
</Description>
</Member>
<Member Name="PMM_KWH_Consumed" DataType="REAL" Dimension="0" Radix="Float" Hidden="false" ExternalAccess="Read/Write">
<Description>
<![CDATA[Total energy consumed over time in kilowatt-hours (kWh)]]>
</Description>
</Member>
<Member Name="PMM_Max_Total_Power" DataType="REAL" Dimension="0" Radix="Float" Hidden="false" ExternalAccess="Read/Write">
<Description>
<![CDATA[Highest recorded real power usage in kilowatts (kW)]]>
</Description>
</Member>
<Member Name="Alarm" DataType="UDT_ALARMS_PMM" Dimension="0" Radix="NullType" Hidden="false" ExternalAccess="Read/Write"/>
</Members>
<Dependencies>
<Dependency Type="DataType" Name="UDT_ALARMS_PMM"/>
</Dependencies>
</DataType>
</DataTypes>
<AddOnInstructionDefinitions Use="Context">
<AddOnInstructionDefinition Name="AOI_PMM" Revision="1.0" ExecutePrescan="false" ExecutePostscan="false" ExecuteEnableInFalse="false" CreatedDate="2025-07-15T11:44:04.434Z" CreatedBy="LCIBATUMI\guga.kakhadze" EditedDate="2025-07-15T12:16:40.504Z" EditedBy="LCIBATUMI\guga.kakhadze" SoftwareRevision="v36.00">
<Parameters>
<Parameter Name="EnableIn" TagType="Base" DataType="BOOL" Usage="Input" Radix="Decimal" Required="false" Visible="false" ExternalAccess="Read Only">
<Description>
<![CDATA[Enable Input - System Defined Parameter]]>
</Description>
</Parameter>
<Parameter Name="EnableOut" TagType="Base" DataType="BOOL" Usage="Output" Radix="Decimal" Required="false" Visible="false" ExternalAccess="Read Only">
<Description>
<![CDATA[Enable Output - System Defined Parameter]]>
</Description>
</Parameter>
<Parameter Name="PMM_Input1" TagType="Base" DataType="AB:1420_V2_ENT_BC244CBD:I:0" Usage="InOut" Required="true" Visible="true" Constant="false"/>
<Parameter Name="PMM_Input2" TagType="Base" DataType="AB:1420_V2_ENT_A691F258:I:0" Usage="InOut" Required="true" Visible="true" Constant="false"/>
<Parameter Name="PMM_Input3" TagType="Base" DataType="AB:1420_V2_ENT_BC1E731C:I:0" Usage="InOut" Required="true" Visible="true" Constant="false"/>
<Parameter Name="PMM_Input4" TagType="Base" DataType="AB:1420_V2_ENT_922708DF:I:0" Usage="InOut" Required="true" Visible="true" Constant="false"/>
</Parameters>
<LocalTags>
<LocalTag Name="HMI" DataType="UDT_HMI_PMM" ExternalAccess="None">
<DefaultData Format="L5K">
<![CDATA[[0,0.00000000e+000,0.00000000e+000,0.00000000e+000,[0]]]]>
</DefaultData>
<DefaultData Format="Decorated">
<Structure DataType="UDT_HMI_PMM">
<DataValueMember Name="STATE" DataType="DINT" Radix="Decimal" Value="0"/>
<DataValueMember Name="PMM_Total_Power" DataType="REAL" Radix="Float" Value="0.0"/>
<DataValueMember Name="PMM_KWH_Consumed" DataType="REAL" Radix="Float" Value="0.0"/>
<DataValueMember Name="PMM_Max_Total_Power" DataType="REAL" Radix="Float" Value="0.0"/>
<StructureMember Name="Alarm" DataType="UDT_ALARMS_PMM">
<DataValueMember Name="PMM_Communication_Fault" DataType="BOOL" Value="0"/>
</StructureMember>
</Structure>
</DefaultData>
</LocalTag>
<LocalTag Name="Communication_Fault" DataType="BOOL" Radix="Decimal" ExternalAccess="None">
<Description>
<![CDATA[Communication Faulted]]>
</Description>
<DefaultData Format="L5K">
<![CDATA[0]]>
</DefaultData>
<DefaultData Format="Decorated">
<DataValue DataType="BOOL" Radix="Decimal" Value="0"/>
</DefaultData>
</LocalTag>
</LocalTags>
<Routines>
<Routine Name="Logic" Type="RLL">
<RLLContent>
<Rung Number="0" Type="N">
<Text>
<![CDATA[XIC(PMM_Input1.ConnectionFaulted)OTE(Communication_Fault);]]>
</Text>
</Rung>
<Rung Number="1" Type="N">
<Text>
<![CDATA[MOVE(PMM_Input2.TotalRealPower,HMI.PMM_Total_Power)MOVE(PMM_Input3.kWhConsumed,HMI.PMM_KWH_Consumed)MOVE(PMM_Input4.MaxTotalRealPwr,HMI.PMM_Max_Total_Power);]]>
</Text>
</Rung>
<Rung Number="2" Type="N">
<Comment>
<![CDATA[Running
]]>
</Comment>
<Text>
<![CDATA[XIO(Communication_Fault)MOVE(0,HMI.STATE);]]>
</Text>
</Rung>
<Rung Number="3" Type="N">
<Comment>
<![CDATA[Communication Faulted
]]>
</Comment>
<Text>
<![CDATA[XIC(Communication_Fault)MOVE(1,HMI.STATE);]]>
</Text>
</Rung>
<Rung Number="4" Type="N">
<Text>
<![CDATA[XIC(Communication_Fault)OTE(HMI.Alarm.PMM_Communication_Fault);]]>
</Text>
</Rung>
</RLLContent>
</Routine>
</Routines>
<Dependencies>
<Dependency Type="DataType" Name="UDT_HMI_PMM"/>
</Dependencies>
</AddOnInstructionDefinition>
</AddOnInstructionDefinitions>
</Controller>
</RSLogix5000Content>