{"level": "INFO", "message": "PLC Generation Workflow started", "timestamp": "2025-09-04T20:20:21.960866", "module": "__main__", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "excel_file": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/PLC Data Generator/data/SAT9_MCM05.xlsx", "project_name": "SAT9_MCM05"}
|
|
{"level": "INFO", "message": "Starting data processing step", "timestamp": "2025-09-04T20:20:21.961208", "module": "__main__", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
|
|
=== Step 1: PLC Data Generator stdout ===
|
|
Loading IO path mappings...
|
|
Loaded IO path mappings:
|
|
APF: 11 rows
|
|
M12DR: 16 rows
|
|
Hub: 16 rows
|
|
SorterHub: 16 rows
|
|
SIO: 16 rows
|
|
IB16: 16 rows
|
|
OB16E: 16 rows
|
|
IB16S: 16 rows
|
|
Available sheets: ['DESC_PLC', 'NETWORK_PLC']
|
|
Found DESC sheet: DESC_PLC
|
|
Found NETWORK sheet: NETWORK_PLC
|
|
|
|
DESC columns: ['TAGNAME', 'TERM', 'DESCA', 'DESCB']
|
|
NETWORK columns: ['DPM', 'DPM_IP', 'Name', 'PartNumber', 'IP']
|
|
|
|
Classifying signals and adding IO paths...
|
|
|
|
Signal classification results:
|
|
SPARE: 490
|
|
I: 396
|
|
IOLink: 149
|
|
O: 37
|
|
|
|
Device type distribution:
|
|
Hub: 512
|
|
M12DR: 512
|
|
IB16: 16
|
|
OB16E: 16
|
|
IB16S: 16
|
|
|
|
IO Path mapping results:
|
|
Successful mappings: 1072/1072 (100.0%)
|
|
|
|
Found 35 TAGNAMEs present in DESC but not in NETWORK_PLC.
|
|
|
|
Adding unique DPM names not present in DESC or NETWORK_PLC.Name: ['DPM1_VS01B', 'DPM1_VS01C']
|
|
|
|
================================================================================
|
|
WARNING: The following issues were found but processing will continue:
|
|
================================================================================
|
|
- TAGNAME 'SLOT5_IB16' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'SLOT6_OB16E' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'SLOT7_IB16S' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01B_FIOM1' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01B_FIOM10' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01B_FIOM11' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01B_FIOM12' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01B_FIOM13' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01B_FIOM14' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01B_FIOM15' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01B_FIOM16' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01B_FIOM17' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01B_FIOM2' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01B_FIOM3' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01B_FIOM4' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01B_FIOM5' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01B_FIOM6' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01B_FIOM7' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01B_FIOM8' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01C_FIOM1' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01C_FIOM10' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01C_FIOM11' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01C_FIOM12' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01C_FIOM13' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01C_FIOM14' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01C_FIOM15' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01C_FIOM16' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01C_FIOM2' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01C_FIOM3' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01C_FIOM4' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01C_FIOM5' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01C_FIOM6' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01C_FIOM7' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01C_FIOM8' from DESC sheet not found in NETWORK_PLC sheet.
|
|
- TAGNAME 'VS01C_FIOM9' from DESC sheet not found in NETWORK_PLC sheet.
|
|
================================================================================
|
|
|
|
Continuing with processing...
|
|
|
|
Normalizing TAGNAME, DESC, and IO_PATH columns for VFDs only in the final output...
|
|
|
|
Final result has 1105 rows
|
|
Sample of merged data:
|
|
TAGNAME TERM ... DEVICE_TYPE IO_PATH
|
|
0 VS01B_FIOM1 IO00 ... M12DR VS01B_FIOM1:I.IOLink00
|
|
1 VS01B_FIOM1 IO01 ... M12DR VS01B_FIOM1:I.Pt01.Data
|
|
2 VS01B_FIOM1 IO02 ... M12DR VS01B_FIOM1:I.IOLink02
|
|
3 VS01B_FIOM1 IO03 ... M12DR VS01B_FIOM1:I.Pt03.Data
|
|
4 VS01B_FIOM1 IO04 ... M12DR VS01B_FIOM1:I.Pt04.Data
|
|
5 VS01B_FIOM1 IO05 ... M12DR VS01B_FIOM1:O.Pt05.Data
|
|
6 VS01B_FIOM1 IO06 ... M12DR VS01B_FIOM1:I.Pt06.Data
|
|
7 VS01B_FIOM1 IO07 ... M12DR VS01B_FIOM1:O.Pt07.Data
|
|
8 VS01B_FIOM1 IO08 ... M12DR VS01B_FIOM1:I.IOLink08
|
|
9 VS01B_FIOM1 IO09 ... M12DR VS01B_FIOM1:I.Pt09.Data
|
|
|
|
[10 rows x 11 columns]
|
|
|
|
New Excel file created: SAT9_MCM05_DESC_IP_MERGED.xlsx
|
|
The file contains all original sheets plus the new 'DESC_IP' sheet with merged data.
|
|
DEBUG: Processing Excel file: /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/PLC Data Generator/data/SAT9_MCM05.xlsx
|
|
DEBUG: Full project pattern matched: SAT9_MCM05
|
|
DEBUG: Final subsystem name: SAT9_MCM05
|
|
Reading input file: SAT9_MCM05_DESC_IP_MERGED.xlsx
|
|
Removed 149 IOLink rows (including beacons, FIOH channels, and all other IOLink entries)
|
|
Added 266 rows for beacon lights
|
|
Removed 33 blank name/description rows
|
|
Saving output file: SAT9_MCM05_OUTPUT.csv
|
|
Processing complete!
|
|
Created standard output file: DESC_IP_MERGED.xlsx
|
|
|
|
=== Step 1: PLC Data Generator stderr ===
|
|
|
|
=== Step 1 File Copy ===
|
|
Copied SAT9_MCM05_DESC_IP_MERGED.xlsx to /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/DESC_IP_MERGED.xlsx
|
|
{"level": "INFO", "message": "Data processing completed successfully", "timestamp": "2025-09-04T20:20:25.178901", "module": "__main__", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Starting routine generation step", "timestamp": "2025-09-04T20:20:25.179138", "module": "__main__", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Logging to file: /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/logs/workflow_SAT9_MCM05_20250904_202021.log", "timestamp": "2025-09-04T20:20:27.040017", "module": "__main__", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "=== Generating All PLC Artifacts ===", "timestamp": "2025-09-04T20:20:27.042186", "module": "__main__", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Generating SafetyProgram L5X...", "timestamp": "2025-09-04T20:20:27.042456", "module": "__main__", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "WARNING", "message": "LimitedSafetyProgramGenerator is deprecated; using ModernSafetyProgramGenerator", "timestamp": "2025-09-04T20:20:27.056169", "module": "src.container", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Starting ModernSafetyProgramGenerator generation", "timestamp": "2025-09-04T20:20:27.056516", "module": "ModernSafetyProgramGenerator", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Creating SafetyProgram XML structure", "timestamp": "2025-09-04T20:20:27.056709", "module": "ModernSafetyProgramGenerator", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Registered plugin: main_routine (core)", "timestamp": "2025-09-04T20:20:27.070700", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: apf (device)", "timestamp": "2025-09-04T20:20:27.078339", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: belt_tracking (device)", "timestamp": "2025-09-04T20:20:27.083158", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: cb_monitor (device)", "timestamp": "2025-09-04T20:20:27.087785", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: d2c_chute (device)", "timestamp": "2025-09-04T20:20:27.093065", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: dpm (device)", "timestamp": "2025-09-04T20:20:27.098758", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: encoder (device)", "timestamp": "2025-09-04T20:20:27.103738", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: estops (safety)", "timestamp": "2025-09-04T20:20:27.114224", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: estop_check (safety)", "timestamp": "2025-09-04T20:20:27.119503", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: extendo (device)", "timestamp": "2025-09-04T20:20:27.124174", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: fioh (device)", "timestamp": "2025-09-04T20:20:27.129217", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: fiom (device)", "timestamp": "2025-09-04T20:20:27.134148", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: flow_ctrl (device)", "timestamp": "2025-09-04T20:20:27.138863", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: fpe (device)", "timestamp": "2025-09-04T20:20:27.144211", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: inputs (safety)", "timestamp": "2025-09-04T20:20:27.149676", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: jpe (device)", "timestamp": "2025-09-04T20:20:27.154261", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: mcm (core)", "timestamp": "2025-09-04T20:20:27.159188", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: outputs (safety)", "timestamp": "2025-09-04T20:20:27.163521", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: pb_chute (device)", "timestamp": "2025-09-04T20:20:27.167211", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: pmm (device)", "timestamp": "2025-09-04T20:20:27.171541", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: rack (core)", "timestamp": "2025-09-04T20:20:27.175779", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: resets (safety)", "timestamp": "2025-09-04T20:20:27.180006", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: safety_tag_map (core)", "timestamp": "2025-09-04T20:20:27.184007", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: safety_tag_mapping (safety)", "timestamp": "2025-09-04T20:20:27.188296", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: speed_ctrl (device)", "timestamp": "2025-09-04T20:20:27.192691", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: station_epc (safety)", "timestamp": "2025-09-04T20:20:27.195906", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: station_jr_chute (device)", "timestamp": "2025-09-04T20:20:27.199054", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: station_jr_pb (device)", "timestamp": "2025-09-04T20:20:27.202076", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: station_ss_pb (device)", "timestamp": "2025-09-04T20:20:27.205017", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: station_s_pb (device)", "timestamp": "2025-09-04T20:20:27.208360", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: taching_belts (device)", "timestamp": "2025-09-04T20:20:27.211373", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "DEBUG", "message": "Registered plugin: zones (safety)", "timestamp": "2025-09-04T20:20:27.215052", "module": "src.plugin_system", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "plugin_discovery"}
|
|
{"level": "INFO", "message": "Generating safety routines...", "timestamp": "2025-09-04T20:20:27.215301", "module": "ModernSafetyProgramGenerator", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin inputs cannot generate with current data", "timestamp": "2025-09-04T20:20:27.942095", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin outputs cannot generate with current data", "timestamp": "2025-09-04T20:20:27.945032", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin resets cannot generate with current data", "timestamp": "2025-09-04T20:20:27.945242", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Zones: subsystem key", "timestamp": "2025-09-04T20:20:27.946580", "module": "src.data_loader", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "subsystem": "DEFAULT", "found": false}
|
|
{"level": "DEBUG", "message": "Zones: heuristic best match", "timestamp": "2025-09-04T20:20:27.960183", "module": "src.data_loader", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "best_key": "MCM01", "score": 0}
|
|
{"level": "DEBUG", "message": "Zones: using DEFAULT group", "timestamp": "2025-09-04T20:20:27.960469", "module": "src.data_loader", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "default_count": 1}
|
|
{"level": "DEBUG", "message": "Zones: loaded", "timestamp": "2025-09-04T20:20:27.961063", "module": "src.data_loader", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "rows": 1}
|
|
{"level": "DEBUG", "message": "Generating routine: zones", "timestamp": "2025-09-04T20:20:27.961262", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Available DCS controllers: {}", "timestamp": "2025-09-04T20:20:27.961741", "module": "src.routines.zones", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Successfully generated routine: zones", "timestamp": "2025-09-04T20:20:27.962097", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin estops cannot generate with current data", "timestamp": "2025-09-04T20:20:27.962278", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Safety routine generation results: {'inputs': False, 'outputs': False, 'resets': False, 'zones': True, 'estops': False}", "timestamp": "2025-09-04T20:20:27.962423", "module": "ModernSafetyProgramGenerator", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Added safety tag map with 1 tags", "timestamp": "2025-09-04T20:20:27.967245", "module": "ModernSafetyProgramGenerator", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Routines created (2): MainRoutine, R030_ZONES", "timestamp": "2025-09-04T20:20:27.967408", "module": "ModernSafetyProgramGenerator", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "summary"}
|
|
{"level": "INFO", "message": "- R030_ZONES: 1 rungs | example: XIC(MCM_EPB_DCS_CTRL.O1)OTE(EStop_MCM_OK);", "timestamp": "2025-09-04T20:20:27.967561", "module": "ModernSafetyProgramGenerator", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "summary"}
|
|
{"level": "INFO", "message": "- MainRoutine: 1 rungs | example: [JSR(R010_INPUTS,0) ,JSR(R011_OUTPUTS,0) ,JSR(R012_RESETS,0) ,JSR(R020_ESTOPS,0) ,JSR(R030_ZONES,0) ];", "timestamp": "2025-09-04T20:20:27.967714", "module": "ModernSafetyProgramGenerator", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "summary"}
|
|
{"level": "INFO", "message": "Successfully completed ModernSafetyProgramGenerator generation", "timestamp": "2025-09-04T20:20:27.967851", "module": "ModernSafetyProgramGenerator", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Written ModernSafetyProgramGenerator to /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/generated_projects/SAT9_MCM05/SafetyProgram_Generated.L5X", "timestamp": "2025-09-04T20:20:27.970061", "module": "ModernSafetyProgramGenerator", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "[SUCCESS] SafetyProgram written to /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/generated_projects/SAT9_MCM05/SafetyProgram_Generated.L5X", "timestamp": "2025-09-04T20:20:28.034977", "module": "__main__", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Generating MainProgram L5X...", "timestamp": "2025-09-04T20:20:28.035202", "module": "__main__", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "WARNING", "message": "LimitedMainProgramGenerator is deprecated; using ModernMainProgramGenerator", "timestamp": "2025-09-04T20:20:28.035380", "module": "src.container", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Starting ModernMainProgramGenerator generation", "timestamp": "2025-09-04T20:20:28.035584", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Creating MainProgram XML structure", "timestamp": "2025-09-04T20:20:28.035716", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Adding controller tags...", "timestamp": "2025-09-04T20:20:28.035857", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Zones: subsystem key", "timestamp": "2025-09-04T20:20:28.111470", "module": "src.data_loader", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "subsystem": "DEFAULT", "found": false}
|
|
{"level": "DEBUG", "message": "Zones: heuristic best match", "timestamp": "2025-09-04T20:20:28.123469", "module": "src.data_loader", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "best_key": "MCM01", "score": 0}
|
|
{"level": "DEBUG", "message": "Zones: using DEFAULT group", "timestamp": "2025-09-04T20:20:28.123963", "module": "src.data_loader", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "default_count": 1}
|
|
{"level": "DEBUG", "message": "Zones: loaded", "timestamp": "2025-09-04T20:20:28.124522", "module": "src.data_loader", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "rows": 1}
|
|
{"level": "DEBUG", "message": "Extracting FPE data", "timestamp": "2025-09-04T20:20:28.180393", "module": "DataLoader", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "data_extraction", "type": "FPE"}
|
|
{"level": "INFO", "message": "Data: FPE count=351", "timestamp": "2025-09-04T20:20:28.181635", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012003_PE1 base=S012003_PE1", "timestamp": "2025-09-04T20:20:28.182038", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012003_PE1", "timestamp": "2025-09-04T20:20:28.182704", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012003_PE1: conveyor=S012003_PE1_VFD1.CTRL parent_fault=S012003_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012003_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.184239", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012003_PE2 base=S012003_PE2", "timestamp": "2025-09-04T20:20:28.184495", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012003_PE2", "timestamp": "2025-09-04T20:20:28.184915", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012003_PE2: conveyor=S012003_PE2_VFD1.CTRL parent_fault=S012003_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012003_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.186120", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012003_PE3 base=S012003_PE3", "timestamp": "2025-09-04T20:20:28.186393", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012003_PE3", "timestamp": "2025-09-04T20:20:28.186751", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012003_PE3: conveyor=S012003_PE3_VFD1.CTRL parent_fault=S012003_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012003_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.188048", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012001_PE1 base=S012001_PE1", "timestamp": "2025-09-04T20:20:28.188307", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012001_PE1", "timestamp": "2025-09-04T20:20:28.188656", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012001_PE1: conveyor=S012001_PE1_VFD1.CTRL parent_fault=S012001_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012001_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.189944", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012001_PE2 base=S012001_PE2", "timestamp": "2025-09-04T20:20:28.190195", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012001_PE2", "timestamp": "2025-09-04T20:20:28.190857", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012001_PE2: conveyor=S012001_PE2_VFD1.CTRL parent_fault=S012001_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012001_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.192364", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012001_PE3 base=S012001_PE3", "timestamp": "2025-09-04T20:20:28.192685", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012001_PE3", "timestamp": "2025-09-04T20:20:28.193102", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012001_PE3: conveyor=S012001_PE3_VFD1.CTRL parent_fault=S012001_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012001_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.194558", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012005_PE1 base=S012005_PE1", "timestamp": "2025-09-04T20:20:28.194823", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012005_PE1", "timestamp": "2025-09-04T20:20:28.195247", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012005_PE1: conveyor=S012005_PE1_VFD1.CTRL parent_fault=S012005_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012005_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.196606", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012005_PE2 base=S012005_PE2", "timestamp": "2025-09-04T20:20:28.196859", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012005_PE2", "timestamp": "2025-09-04T20:20:28.197251", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012005_PE2: conveyor=S012005_PE2_VFD1.CTRL parent_fault=S012005_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012005_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.198537", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012005_PE3 base=S012005_PE3", "timestamp": "2025-09-04T20:20:28.198771", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012005_PE3", "timestamp": "2025-09-04T20:20:28.199188", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012005_PE3: conveyor=S012005_PE3_VFD1.CTRL parent_fault=S012005_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012005_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.200533", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012007_PE1 base=S012007_PE1", "timestamp": "2025-09-04T20:20:28.200800", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012007_PE1", "timestamp": "2025-09-04T20:20:28.201195", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012007_PE1: conveyor=S012007_PE1_VFD1.CTRL parent_fault=S012007_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012007_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.202399", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012007_PE2 base=S012007_PE2", "timestamp": "2025-09-04T20:20:28.202654", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012007_PE2", "timestamp": "2025-09-04T20:20:28.203066", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012007_PE2: conveyor=S012007_PE2_VFD1.CTRL parent_fault=S012007_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012007_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.204566", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012007_PE3 base=S012007_PE3", "timestamp": "2025-09-04T20:20:28.204848", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012007_PE3", "timestamp": "2025-09-04T20:20:28.205281", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012007_PE3: conveyor=S012007_PE3_VFD1.CTRL parent_fault=S012007_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012007_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.207171", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012041_PE1 base=S012041_PE1", "timestamp": "2025-09-04T20:20:28.207496", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012041_PE1", "timestamp": "2025-09-04T20:20:28.208007", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012041_PE1: conveyor=S012041_PE1_VFD1.CTRL parent_fault=S012041_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012041_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.209278", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012041_PE2 base=S012041_PE2", "timestamp": "2025-09-04T20:20:28.209514", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012041_PE2", "timestamp": "2025-09-04T20:20:28.209883", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012041_PE2: conveyor=S012041_PE2_VFD1.CTRL parent_fault=S012041_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012041_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.211119", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012041_PE3 base=S012041_PE3", "timestamp": "2025-09-04T20:20:28.211380", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012041_PE3", "timestamp": "2025-09-04T20:20:28.211829", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012041_PE3: conveyor=S012041_PE3_VFD1.CTRL parent_fault=S012041_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012041_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.213122", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012039_PE1 base=S012039_PE1", "timestamp": "2025-09-04T20:20:28.213426", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012039_PE1", "timestamp": "2025-09-04T20:20:28.213885", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012039_PE1: conveyor=S012039_PE1_VFD1.CTRL parent_fault=S012039_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012039_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.215130", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012039_PE2 base=S012039_PE2", "timestamp": "2025-09-04T20:20:28.215641", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012039_PE2", "timestamp": "2025-09-04T20:20:28.216138", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012039_PE2: conveyor=S012039_PE2_VFD1.CTRL parent_fault=S012039_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012039_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.217425", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012039_PE3 base=S012039_PE3", "timestamp": "2025-09-04T20:20:28.217701", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012039_PE3", "timestamp": "2025-09-04T20:20:28.218106", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012039_PE3: conveyor=S012039_PE3_VFD1.CTRL parent_fault=S012039_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012039_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.219350", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012043_PE1 base=S012043_PE1", "timestamp": "2025-09-04T20:20:28.219614", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012043_PE1", "timestamp": "2025-09-04T20:20:28.220018", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012043_PE1: conveyor=S012043_PE1_VFD1.CTRL parent_fault=S012043_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012043_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.221586", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012043_PE2 base=S012043_PE2", "timestamp": "2025-09-04T20:20:28.221992", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012043_PE2", "timestamp": "2025-09-04T20:20:28.222460", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012043_PE2: conveyor=S012043_PE2_VFD1.CTRL parent_fault=S012043_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012043_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.223657", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012043_PE3 base=S012043_PE3", "timestamp": "2025-09-04T20:20:28.224064", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012043_PE3", "timestamp": "2025-09-04T20:20:28.224616", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012043_PE3: conveyor=S012043_PE3_VFD1.CTRL parent_fault=S012043_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012043_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.225963", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012045_PE1 base=S012045_PE1", "timestamp": "2025-09-04T20:20:28.226205", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012045_PE1", "timestamp": "2025-09-04T20:20:28.226618", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012045_PE1: conveyor=S012045_PE1_VFD1.CTRL parent_fault=S012045_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012045_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.228229", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012045_PE2 base=S012045_PE2", "timestamp": "2025-09-04T20:20:28.228533", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012045_PE2", "timestamp": "2025-09-04T20:20:28.228907", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012045_PE2: conveyor=S012045_PE2_VFD1.CTRL parent_fault=S012045_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012045_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.230172", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012045_PE3 base=S012045_PE3", "timestamp": "2025-09-04T20:20:28.230418", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012045_PE3", "timestamp": "2025-09-04T20:20:28.230871", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012045_PE3: conveyor=S012045_PE3_VFD1.CTRL parent_fault=S012045_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012045_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.232290", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012044_PE1 base=S012044_PE1", "timestamp": "2025-09-04T20:20:28.232547", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012044_PE1", "timestamp": "2025-09-04T20:20:28.232918", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012044_PE1: conveyor=S012044_PE1_VFD1.CTRL parent_fault=S012044_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012044_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.234077", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012044_PE2 base=S012044_PE2", "timestamp": "2025-09-04T20:20:28.234307", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012044_PE2", "timestamp": "2025-09-04T20:20:28.234730", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012044_PE2: conveyor=S012044_PE2_VFD1.CTRL parent_fault=S012044_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012044_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.236052", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012044_PE3 base=S012044_PE3", "timestamp": "2025-09-04T20:20:28.236295", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012044_PE3", "timestamp": "2025-09-04T20:20:28.236732", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012044_PE3: conveyor=S012044_PE3_VFD1.CTRL parent_fault=S012044_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012044_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.238058", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012046_PE1 base=S012046_PE1", "timestamp": "2025-09-04T20:20:28.238306", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012046_PE1", "timestamp": "2025-09-04T20:20:28.238758", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012046_PE1: conveyor=S012046_PE1_VFD1.CTRL parent_fault=S012046_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012046_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.240015", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012046_PE2 base=S012046_PE2", "timestamp": "2025-09-04T20:20:28.240416", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012046_PE2", "timestamp": "2025-09-04T20:20:28.240922", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012046_PE2: conveyor=S012046_PE2_VFD1.CTRL parent_fault=S012046_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012046_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.242193", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012046_PE3 base=S012046_PE3", "timestamp": "2025-09-04T20:20:28.242476", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012046_PE3", "timestamp": "2025-09-04T20:20:28.242969", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012046_PE3: conveyor=S012046_PE3_VFD1.CTRL parent_fault=S012046_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012046_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.244242", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012042_PE1 base=S012042_PE1", "timestamp": "2025-09-04T20:20:28.244522", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012042_PE1", "timestamp": "2025-09-04T20:20:28.244977", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012042_PE1: conveyor=S012042_PE1_VFD1.CTRL parent_fault=S012042_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012042_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.246237", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012042_PE2 base=S012042_PE2", "timestamp": "2025-09-04T20:20:28.246478", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012042_PE2", "timestamp": "2025-09-04T20:20:28.246933", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012042_PE2: conveyor=S012042_PE2_VFD1.CTRL parent_fault=S012042_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012042_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.248238", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012042_PE3 base=S012042_PE3", "timestamp": "2025-09-04T20:20:28.248472", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012042_PE3", "timestamp": "2025-09-04T20:20:28.248910", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012042_PE3: conveyor=S012042_PE3_VFD1.CTRL parent_fault=S012042_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012042_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.250196", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012049_PE1 base=S012049_PE1", "timestamp": "2025-09-04T20:20:28.250458", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012049_PE1", "timestamp": "2025-09-04T20:20:28.250910", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012049_PE1: conveyor=S012049_PE1_VFD1.CTRL parent_fault=S012049_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012049_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.252173", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012049_PE2 base=S012049_PE2", "timestamp": "2025-09-04T20:20:28.252442", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012049_PE2", "timestamp": "2025-09-04T20:20:28.252858", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012049_PE2: conveyor=S012049_PE2_VFD1.CTRL parent_fault=S012049_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012049_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.254152", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012049_PE3 base=S012049_PE3", "timestamp": "2025-09-04T20:20:28.254380", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012049_PE3", "timestamp": "2025-09-04T20:20:28.254770", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012049_PE3: conveyor=S012049_PE3_VFD1.CTRL parent_fault=S012049_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012049_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.255974", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012047_PE1 base=S012047_PE1", "timestamp": "2025-09-04T20:20:28.256225", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012047_PE1", "timestamp": "2025-09-04T20:20:28.256683", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012047_PE1: conveyor=S012047_PE1_VFD1.CTRL parent_fault=S012047_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012047_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.258121", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012047_PE2 base=S012047_PE2", "timestamp": "2025-09-04T20:20:28.258449", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012047_PE2", "timestamp": "2025-09-04T20:20:28.258930", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012047_PE2: conveyor=S012047_PE2_VFD1.CTRL parent_fault=S012047_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012047_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.260265", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012047_PE3 base=S012047_PE3", "timestamp": "2025-09-04T20:20:28.260513", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012047_PE3", "timestamp": "2025-09-04T20:20:28.260963", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012047_PE3: conveyor=S012047_PE3_VFD1.CTRL parent_fault=S012047_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012047_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.262212", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012051_PE1 base=S012051_PE1", "timestamp": "2025-09-04T20:20:28.262476", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012051_PE1", "timestamp": "2025-09-04T20:20:28.262875", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012051_PE1: conveyor=S012051_PE1_VFD1.CTRL parent_fault=S012051_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012051_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.264070", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012051_PE2 base=S012051_PE2", "timestamp": "2025-09-04T20:20:28.264330", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012051_PE2", "timestamp": "2025-09-04T20:20:28.264721", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012051_PE2: conveyor=S012051_PE2_VFD1.CTRL parent_fault=S012051_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012051_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.265959", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012051_PE3 base=S012051_PE3", "timestamp": "2025-09-04T20:20:28.266224", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012051_PE3", "timestamp": "2025-09-04T20:20:28.266620", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012051_PE3: conveyor=S012051_PE3_VFD1.CTRL parent_fault=S012051_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012051_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.267878", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012053_PE1 base=S012053_PE1", "timestamp": "2025-09-04T20:20:28.268147", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012053_PE1", "timestamp": "2025-09-04T20:20:28.268550", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012053_PE1: conveyor=S012053_PE1_VFD1.CTRL parent_fault=S012053_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012053_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.269879", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012053_PE2 base=S012053_PE2", "timestamp": "2025-09-04T20:20:28.270151", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012053_PE2", "timestamp": "2025-09-04T20:20:28.270583", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012053_PE2: conveyor=S012053_PE2_VFD1.CTRL parent_fault=S012053_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012053_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.271920", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012053_PE3 base=S012053_PE3", "timestamp": "2025-09-04T20:20:28.272207", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012053_PE3", "timestamp": "2025-09-04T20:20:28.272653", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012053_PE3: conveyor=S012053_PE3_VFD1.CTRL parent_fault=S012053_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012053_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.274165", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012052_PE1 base=S012052_PE1", "timestamp": "2025-09-04T20:20:28.274451", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012052_PE1", "timestamp": "2025-09-04T20:20:28.274900", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012052_PE1: conveyor=S012052_PE1_VFD1.CTRL parent_fault=S012052_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012052_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.276164", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012052_PE2 base=S012052_PE2", "timestamp": "2025-09-04T20:20:28.276419", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012052_PE2", "timestamp": "2025-09-04T20:20:28.276819", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012052_PE2: conveyor=S012052_PE2_VFD1.CTRL parent_fault=S012052_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012052_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.278127", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012052_PE3 base=S012052_PE3", "timestamp": "2025-09-04T20:20:28.278382", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012052_PE3", "timestamp": "2025-09-04T20:20:28.278809", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012052_PE3: conveyor=S012052_PE3_VFD1.CTRL parent_fault=S012052_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012052_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.280072", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012050_PE1 base=S012050_PE1", "timestamp": "2025-09-04T20:20:28.280323", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012050_PE1", "timestamp": "2025-09-04T20:20:28.280720", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012050_PE1: conveyor=S012050_PE1_VFD1.CTRL parent_fault=S012050_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012050_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.281986", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012050_PE2 base=S012050_PE2", "timestamp": "2025-09-04T20:20:28.282198", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012050_PE2", "timestamp": "2025-09-04T20:20:28.282592", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012050_PE2: conveyor=S012050_PE2_VFD1.CTRL parent_fault=S012050_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012050_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.283953", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012050_PE3 base=S012050_PE3", "timestamp": "2025-09-04T20:20:28.284312", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012050_PE3", "timestamp": "2025-09-04T20:20:28.284786", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012050_PE3: conveyor=S012050_PE3_VFD1.CTRL parent_fault=S012050_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012050_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.286070", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012048_PE1 base=S012048_PE1", "timestamp": "2025-09-04T20:20:28.286332", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012048_PE1", "timestamp": "2025-09-04T20:20:28.286729", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012048_PE1: conveyor=S012048_PE1_VFD1.CTRL parent_fault=S012048_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012048_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.288114", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012048_PE2 base=S012048_PE2", "timestamp": "2025-09-04T20:20:28.288383", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012048_PE2", "timestamp": "2025-09-04T20:20:28.288792", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012048_PE2: conveyor=S012048_PE2_VFD1.CTRL parent_fault=S012048_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012048_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.290126", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012048_PE3 base=S012048_PE3", "timestamp": "2025-09-04T20:20:28.290651", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012048_PE3", "timestamp": "2025-09-04T20:20:28.291335", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012048_PE3: conveyor=S012048_PE3_VFD1.CTRL parent_fault=S012048_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012048_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.293401", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012057_PE1 base=S012057_PE1", "timestamp": "2025-09-04T20:20:28.293709", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012057_PE1", "timestamp": "2025-09-04T20:20:28.294199", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012057_PE1: conveyor=S012057_PE1_VFD1.CTRL parent_fault=S012057_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012057_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.295767", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012057_PE2 base=S012057_PE2", "timestamp": "2025-09-04T20:20:28.296115", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012057_PE2", "timestamp": "2025-09-04T20:20:28.296593", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012057_PE2: conveyor=S012057_PE2_VFD1.CTRL parent_fault=S012057_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012057_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.298076", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012057_PE3 base=S012057_PE3", "timestamp": "2025-09-04T20:20:28.298429", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012057_PE3", "timestamp": "2025-09-04T20:20:28.298875", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012057_PE3: conveyor=S012057_PE3_VFD1.CTRL parent_fault=S012057_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012057_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.300281", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012055_PE1 base=S012055_PE1", "timestamp": "2025-09-04T20:20:28.300558", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012055_PE1", "timestamp": "2025-09-04T20:20:28.301001", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012055_PE1: conveyor=S012055_PE1_VFD1.CTRL parent_fault=S012055_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012055_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.302344", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012055_PE2 base=S012055_PE2", "timestamp": "2025-09-04T20:20:28.302567", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012055_PE2", "timestamp": "2025-09-04T20:20:28.302933", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012055_PE2: conveyor=S012055_PE2_VFD1.CTRL parent_fault=S012055_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012055_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.304229", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012055_PE3 base=S012055_PE3", "timestamp": "2025-09-04T20:20:28.304510", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012055_PE3", "timestamp": "2025-09-04T20:20:28.304946", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012055_PE3: conveyor=S012055_PE3_VFD1.CTRL parent_fault=S012055_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012055_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.306341", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012059_PE1 base=S012059_PE1", "timestamp": "2025-09-04T20:20:28.306606", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012059_PE1", "timestamp": "2025-09-04T20:20:28.307083", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012059_PE1: conveyor=S012059_PE1_VFD1.CTRL parent_fault=S012059_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012059_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.308393", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012059_PE2 base=S012059_PE2", "timestamp": "2025-09-04T20:20:28.308658", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012059_PE2", "timestamp": "2025-09-04T20:20:28.309051", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012059_PE2: conveyor=S012059_PE2_VFD1.CTRL parent_fault=S012059_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012059_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.310264", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012059_PE3 base=S012059_PE3", "timestamp": "2025-09-04T20:20:28.310512", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012059_PE3", "timestamp": "2025-09-04T20:20:28.310918", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012059_PE3: conveyor=S012059_PE3_VFD1.CTRL parent_fault=S012059_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012059_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.312353", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012061_PE1 base=S012061_PE1", "timestamp": "2025-09-04T20:20:28.312571", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012061_PE1", "timestamp": "2025-09-04T20:20:28.312919", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012061_PE1: conveyor=S012061_PE1_VFD1.CTRL parent_fault=S012061_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012061_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.314289", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012061_PE2 base=S012061_PE2", "timestamp": "2025-09-04T20:20:28.314545", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012061_PE2", "timestamp": "2025-09-04T20:20:28.314966", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012061_PE2: conveyor=S012061_PE2_VFD1.CTRL parent_fault=S012061_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012061_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.316850", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012061_PE3 base=S012061_PE3", "timestamp": "2025-09-04T20:20:28.355589", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012061_PE3", "timestamp": "2025-09-04T20:20:28.356286", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012061_PE3: conveyor=S012061_PE3_VFD1.CTRL parent_fault=S012061_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012061_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.357742", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012060_PE1 base=S012060_PE1", "timestamp": "2025-09-04T20:20:28.358055", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012060_PE1", "timestamp": "2025-09-04T20:20:28.358507", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012060_PE1: conveyor=S012060_PE1_VFD1.CTRL parent_fault=S012060_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012060_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.359765", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012060_PE2 base=S012060_PE2", "timestamp": "2025-09-04T20:20:28.360055", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012060_PE2", "timestamp": "2025-09-04T20:20:28.360470", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012060_PE2: conveyor=S012060_PE2_VFD1.CTRL parent_fault=S012060_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012060_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.361782", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012060_PE3 base=S012060_PE3", "timestamp": "2025-09-04T20:20:28.362043", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012060_PE3", "timestamp": "2025-09-04T20:20:28.362456", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012060_PE3: conveyor=S012060_PE3_VFD1.CTRL parent_fault=S012060_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012060_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.364119", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012062_PE1 base=S012062_PE1", "timestamp": "2025-09-04T20:20:28.364369", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012062_PE1", "timestamp": "2025-09-04T20:20:28.364779", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012062_PE1: conveyor=S012062_PE1_VFD1.CTRL parent_fault=S012062_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012062_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.366051", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012062_PE2 base=S012062_PE2", "timestamp": "2025-09-04T20:20:28.366295", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012062_PE2", "timestamp": "2025-09-04T20:20:28.366709", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012062_PE2: conveyor=S012062_PE2_VFD1.CTRL parent_fault=S012062_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012062_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.368017", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012062_PE3 base=S012062_PE3", "timestamp": "2025-09-04T20:20:28.368265", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012062_PE3", "timestamp": "2025-09-04T20:20:28.368669", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012062_PE3: conveyor=S012062_PE3_VFD1.CTRL parent_fault=S012062_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012062_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.369898", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012058_PE1 base=S012058_PE1", "timestamp": "2025-09-04T20:20:28.370140", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012058_PE1", "timestamp": "2025-09-04T20:20:28.370584", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012058_PE1: conveyor=S012058_PE1_VFD1.CTRL parent_fault=S012058_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012058_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.371825", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012058_PE2 base=S012058_PE2", "timestamp": "2025-09-04T20:20:28.372065", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012058_PE2", "timestamp": "2025-09-04T20:20:28.372469", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012058_PE2: conveyor=S012058_PE2_VFD1.CTRL parent_fault=S012058_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012058_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.373864", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012058_PE3 base=S012058_PE3", "timestamp": "2025-09-04T20:20:28.374208", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012058_PE3", "timestamp": "2025-09-04T20:20:28.374644", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012058_PE3: conveyor=S012058_PE3_VFD1.CTRL parent_fault=S012058_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012058_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.375842", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012056_PE1 base=S012056_PE1", "timestamp": "2025-09-04T20:20:28.376099", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012056_PE1", "timestamp": "2025-09-04T20:20:28.376488", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012056_PE1: conveyor=S012056_PE1_VFD1.CTRL parent_fault=S012056_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012056_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.377818", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012056_PE2 base=S012056_PE2", "timestamp": "2025-09-04T20:20:28.378036", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012056_PE2", "timestamp": "2025-09-04T20:20:28.378495", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012056_PE2: conveyor=S012056_PE2_VFD1.CTRL parent_fault=S012056_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012056_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.379779", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012056_PE3 base=S012056_PE3", "timestamp": "2025-09-04T20:20:28.380079", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012056_PE3", "timestamp": "2025-09-04T20:20:28.380485", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012056_PE3: conveyor=S012056_PE3_VFD1.CTRL parent_fault=S012056_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012056_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.381681", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012065_PE1 base=S012065_PE1", "timestamp": "2025-09-04T20:20:28.381934", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012065_PE1", "timestamp": "2025-09-04T20:20:28.382370", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012065_PE1: conveyor=S012065_PE1_VFD1.CTRL parent_fault=S012065_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012065_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.383631", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012065_PE2 base=S012065_PE2", "timestamp": "2025-09-04T20:20:28.383897", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012065_PE2", "timestamp": "2025-09-04T20:20:28.384328", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012065_PE2: conveyor=S012065_PE2_VFD1.CTRL parent_fault=S012065_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012065_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.385532", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012065_PE3 base=S012065_PE3", "timestamp": "2025-09-04T20:20:28.385759", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012065_PE3", "timestamp": "2025-09-04T20:20:28.386137", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012065_PE3: conveyor=S012065_PE3_VFD1.CTRL parent_fault=S012065_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012065_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.387355", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012063_PE1 base=S012063_PE1", "timestamp": "2025-09-04T20:20:28.387615", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012063_PE1", "timestamp": "2025-09-04T20:20:28.388121", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012063_PE1: conveyor=S012063_PE1_VFD1.CTRL parent_fault=S012063_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012063_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.389311", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012063_PE2 base=S012063_PE2", "timestamp": "2025-09-04T20:20:28.389542", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012063_PE2", "timestamp": "2025-09-04T20:20:28.389925", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012063_PE2: conveyor=S012063_PE2_VFD1.CTRL parent_fault=S012063_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012063_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.391264", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012063_PE3 base=S012063_PE3", "timestamp": "2025-09-04T20:20:28.391518", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012063_PE3", "timestamp": "2025-09-04T20:20:28.391912", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012063_PE3: conveyor=S012063_PE3_VFD1.CTRL parent_fault=S012063_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012063_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.393191", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012067_PE1 base=S012067_PE1", "timestamp": "2025-09-04T20:20:28.393448", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012067_PE1", "timestamp": "2025-09-04T20:20:28.393964", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012067_PE1: conveyor=S012067_PE1_VFD1.CTRL parent_fault=S012067_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012067_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.395208", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012067_PE2 base=S012067_PE2", "timestamp": "2025-09-04T20:20:28.395470", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012067_PE2", "timestamp": "2025-09-04T20:20:28.395876", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012067_PE2: conveyor=S012067_PE2_VFD1.CTRL parent_fault=S012067_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012067_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.397158", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012067_PE3 base=S012067_PE3", "timestamp": "2025-09-04T20:20:28.397413", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012067_PE3", "timestamp": "2025-09-04T20:20:28.397832", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012067_PE3: conveyor=S012067_PE3_VFD1.CTRL parent_fault=S012067_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012067_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.399027", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012069_PE1 base=S012069_PE1", "timestamp": "2025-09-04T20:20:28.399270", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012069_PE1", "timestamp": "2025-09-04T20:20:28.399651", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012069_PE1: conveyor=S012069_PE1_VFD1.CTRL parent_fault=S012069_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012069_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.400905", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012069_PE2 base=S012069_PE2", "timestamp": "2025-09-04T20:20:28.401156", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012069_PE2", "timestamp": "2025-09-04T20:20:28.401541", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012069_PE2: conveyor=S012069_PE2_VFD1.CTRL parent_fault=S012069_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012069_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.402902", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012069_PE3 base=S012069_PE3", "timestamp": "2025-09-04T20:20:28.403151", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012069_PE3", "timestamp": "2025-09-04T20:20:28.403514", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012069_PE3: conveyor=S012069_PE3_VFD1.CTRL parent_fault=S012069_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012069_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.404680", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012068_PE1 base=S012068_PE1", "timestamp": "2025-09-04T20:20:28.404903", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012068_PE1", "timestamp": "2025-09-04T20:20:28.405305", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012068_PE1: conveyor=S012068_PE1_VFD1.CTRL parent_fault=S012068_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012068_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.406542", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012068_PE2 base=S012068_PE2", "timestamp": "2025-09-04T20:20:28.406773", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012068_PE2", "timestamp": "2025-09-04T20:20:28.407182", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012068_PE2: conveyor=S012068_PE2_VFD1.CTRL parent_fault=S012068_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012068_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.408475", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012068_PE3 base=S012068_PE3", "timestamp": "2025-09-04T20:20:28.408947", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012068_PE3", "timestamp": "2025-09-04T20:20:28.409374", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012068_PE3: conveyor=S012068_PE3_VFD1.CTRL parent_fault=S012068_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012068_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.410558", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012066_PE1 base=S012066_PE1", "timestamp": "2025-09-04T20:20:28.410781", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012066_PE1", "timestamp": "2025-09-04T20:20:28.411134", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012066_PE1: conveyor=S012066_PE1_VFD1.CTRL parent_fault=S012066_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012066_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.412360", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012066_PE2 base=S012066_PE2", "timestamp": "2025-09-04T20:20:28.412647", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012066_PE2", "timestamp": "2025-09-04T20:20:28.413073", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012066_PE2: conveyor=S012066_PE2_VFD1.CTRL parent_fault=S012066_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012066_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.414337", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012066_PE3 base=S012066_PE3", "timestamp": "2025-09-04T20:20:28.414575", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012066_PE3", "timestamp": "2025-09-04T20:20:28.414968", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012066_PE3: conveyor=S012066_PE3_VFD1.CTRL parent_fault=S012066_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012066_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.416298", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012064_PE1 base=S012064_PE1", "timestamp": "2025-09-04T20:20:28.416557", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012064_PE1", "timestamp": "2025-09-04T20:20:28.416924", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012064_PE1: conveyor=S012064_PE1_VFD1.CTRL parent_fault=S012064_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012064_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.418064", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012064_PE2 base=S012064_PE2", "timestamp": "2025-09-04T20:20:28.418276", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012064_PE2", "timestamp": "2025-09-04T20:20:28.418649", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012064_PE2: conveyor=S012064_PE2_VFD1.CTRL parent_fault=S012064_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012064_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.419882", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012064_PE3 base=S012064_PE3", "timestamp": "2025-09-04T20:20:28.420172", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012064_PE3", "timestamp": "2025-09-04T20:20:28.420581", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012064_PE3: conveyor=S012064_PE3_VFD1.CTRL parent_fault=S012064_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012064_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.421807", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012006_PE1 base=S012006_PE1", "timestamp": "2025-09-04T20:20:28.422050", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012006_PE1", "timestamp": "2025-09-04T20:20:28.422494", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012006_PE1: conveyor=S012006_PE1_VFD1.CTRL parent_fault=S012006_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012006_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.423884", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012006_PE2 base=S012006_PE2", "timestamp": "2025-09-04T20:20:28.424169", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012006_PE2", "timestamp": "2025-09-04T20:20:28.424682", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012006_PE2: conveyor=S012006_PE2_VFD1.CTRL parent_fault=S012006_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012006_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.425912", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012006_PE3 base=S012006_PE3", "timestamp": "2025-09-04T20:20:28.426147", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012006_PE3", "timestamp": "2025-09-04T20:20:28.426548", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012006_PE3: conveyor=S012006_PE3_VFD1.CTRL parent_fault=S012006_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012006_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.428281", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012008_PE1 base=S012008_PE1", "timestamp": "2025-09-04T20:20:28.428534", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012008_PE1", "timestamp": "2025-09-04T20:20:28.429019", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012008_PE1: conveyor=S012008_PE1_VFD1.CTRL parent_fault=S012008_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012008_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.430238", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012008_PE2 base=S012008_PE2", "timestamp": "2025-09-04T20:20:28.430492", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012008_PE2", "timestamp": "2025-09-04T20:20:28.430947", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012008_PE2: conveyor=S012008_PE2_VFD1.CTRL parent_fault=S012008_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012008_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.432453", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012008_PE3 base=S012008_PE3", "timestamp": "2025-09-04T20:20:28.432742", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012008_PE3", "timestamp": "2025-09-04T20:20:28.433164", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012008_PE3: conveyor=S012008_PE3_VFD1.CTRL parent_fault=S012008_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012008_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.434400", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012004_PE1 base=S012004_PE1", "timestamp": "2025-09-04T20:20:28.434664", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012004_PE1", "timestamp": "2025-09-04T20:20:28.435072", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012004_PE1: conveyor=S012004_PE1_VFD1.CTRL parent_fault=S012004_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012004_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.436336", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012004_PE2 base=S012004_PE2", "timestamp": "2025-09-04T20:20:28.436583", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012004_PE2", "timestamp": "2025-09-04T20:20:28.436947", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012004_PE2: conveyor=S012004_PE2_VFD1.CTRL parent_fault=S012004_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012004_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.438210", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012004_PE3 base=S012004_PE3", "timestamp": "2025-09-04T20:20:28.438476", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012004_PE3", "timestamp": "2025-09-04T20:20:28.438902", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012004_PE3: conveyor=S012004_PE3_VFD1.CTRL parent_fault=S012004_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012004_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.440159", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012002_PE1 base=S012002_PE1", "timestamp": "2025-09-04T20:20:28.440540", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012002_PE1", "timestamp": "2025-09-04T20:20:28.441011", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012002_PE1: conveyor=S012002_PE1_VFD1.CTRL parent_fault=S012002_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012002_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.442281", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012002_PE2 base=S012002_PE2", "timestamp": "2025-09-04T20:20:28.442531", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012002_PE2", "timestamp": "2025-09-04T20:20:28.442963", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012002_PE2: conveyor=S012002_PE2_VFD1.CTRL parent_fault=S012002_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012002_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.444196", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012002_PE3 base=S012002_PE3", "timestamp": "2025-09-04T20:20:28.444438", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012002_PE3", "timestamp": "2025-09-04T20:20:28.444872", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012002_PE3: conveyor=S012002_PE3_VFD1.CTRL parent_fault=S012002_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012002_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.446151", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012018_PE1 base=S012018_PE1", "timestamp": "2025-09-04T20:20:28.446442", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012018_PE1", "timestamp": "2025-09-04T20:20:28.446880", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012018_PE1: conveyor=S012018_PE1_VFD1.CTRL parent_fault=S012018_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012018_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.448134", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012018_PE2 base=S012018_PE2", "timestamp": "2025-09-04T20:20:28.448386", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012018_PE2", "timestamp": "2025-09-04T20:20:28.448806", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012018_PE2: conveyor=S012018_PE2_VFD1.CTRL parent_fault=S012018_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012018_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.450101", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012018_PE3 base=S012018_PE3", "timestamp": "2025-09-04T20:20:28.450366", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012018_PE3", "timestamp": "2025-09-04T20:20:28.450809", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012018_PE3: conveyor=S012018_PE3_VFD1.CTRL parent_fault=S012018_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012018_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.452106", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012020_PE1 base=S012020_PE1", "timestamp": "2025-09-04T20:20:28.452361", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012020_PE1", "timestamp": "2025-09-04T20:20:28.452800", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012020_PE1: conveyor=S012020_PE1_VFD1.CTRL parent_fault=S012020_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012020_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.454064", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012020_PE2 base=S012020_PE2", "timestamp": "2025-09-04T20:20:28.454313", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012020_PE2", "timestamp": "2025-09-04T20:20:28.454718", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012020_PE2: conveyor=S012020_PE2_VFD1.CTRL parent_fault=S012020_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012020_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.456429", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012020_PE3 base=S012020_PE3", "timestamp": "2025-09-04T20:20:28.456677", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012020_PE3", "timestamp": "2025-09-04T20:20:28.457217", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012020_PE3: conveyor=S012020_PE3_VFD1.CTRL parent_fault=S012020_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012020_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.468440", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012016_PE1 base=S012016_PE1", "timestamp": "2025-09-04T20:20:28.468804", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012016_PE1", "timestamp": "2025-09-04T20:20:28.469255", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012016_PE1: conveyor=S012016_PE1_VFD1.CTRL parent_fault=S012016_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012016_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.470540", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012016_PE2 base=S012016_PE2", "timestamp": "2025-09-04T20:20:28.470798", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012016_PE2", "timestamp": "2025-09-04T20:20:28.471195", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012016_PE2: conveyor=S012016_PE2_VFD1.CTRL parent_fault=S012016_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012016_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.472502", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012016_PE3 base=S012016_PE3", "timestamp": "2025-09-04T20:20:28.472745", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012016_PE3", "timestamp": "2025-09-04T20:20:28.473149", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012016_PE3: conveyor=S012016_PE3_VFD1.CTRL parent_fault=S012016_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012016_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.474355", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012014_PE1 base=S012014_PE1", "timestamp": "2025-09-04T20:20:28.474625", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012014_PE1", "timestamp": "2025-09-04T20:20:28.475056", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012014_PE1: conveyor=S012014_PE1_VFD1.CTRL parent_fault=S012014_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012014_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.476578", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012014_PE2 base=S012014_PE2", "timestamp": "2025-09-04T20:20:28.476828", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012014_PE2", "timestamp": "2025-09-04T20:20:28.477272", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012014_PE2: conveyor=S012014_PE2_VFD1.CTRL parent_fault=S012014_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012014_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.478519", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012014_PE3 base=S012014_PE3", "timestamp": "2025-09-04T20:20:28.478779", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012014_PE3", "timestamp": "2025-09-04T20:20:28.479311", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012014_PE3: conveyor=S012014_PE3_VFD1.CTRL parent_fault=S012014_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012014_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.480591", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012022_PE1 base=S012022_PE1", "timestamp": "2025-09-04T20:20:28.480847", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012022_PE1", "timestamp": "2025-09-04T20:20:28.481266", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012022_PE1: conveyor=S012022_PE1_VFD1.CTRL parent_fault=S012022_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH4:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012022_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.482566", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012022_PE2 base=S012022_PE2", "timestamp": "2025-09-04T20:20:28.482829", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012022_PE2", "timestamp": "2025-09-04T20:20:28.483255", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012022_PE2: conveyor=S012022_PE2_VFD1.CTRL parent_fault=S012022_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH4:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012022_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.484643", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012022_PE3 base=S012022_PE3", "timestamp": "2025-09-04T20:20:28.484880", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012022_PE3", "timestamp": "2025-09-04T20:20:28.485273", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012022_PE3: conveyor=S012022_PE3_VFD1.CTRL parent_fault=S012022_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH4:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012022_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.486519", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012025_PE1 base=S012025_PE1", "timestamp": "2025-09-04T20:20:28.486798", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012025_PE1", "timestamp": "2025-09-04T20:20:28.487235", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012025_PE1: conveyor=S012025_PE1_VFD1.CTRL parent_fault=S012025_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012025_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.488642", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012025_PE2 base=S012025_PE2", "timestamp": "2025-09-04T20:20:28.488911", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012025_PE2", "timestamp": "2025-09-04T20:20:28.489323", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012025_PE2: conveyor=S012025_PE2_VFD1.CTRL parent_fault=S012025_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012025_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.490569", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012025_PE3 base=S012025_PE3", "timestamp": "2025-09-04T20:20:28.490813", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012025_PE3", "timestamp": "2025-09-04T20:20:28.491241", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012025_PE3: conveyor=S012025_PE3_VFD1.CTRL parent_fault=S012025_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012025_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.492760", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012023_PE1 base=S012023_PE1", "timestamp": "2025-09-04T20:20:28.493020", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012023_PE1", "timestamp": "2025-09-04T20:20:28.493461", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012023_PE1: conveyor=S012023_PE1_VFD1.CTRL parent_fault=S012023_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012023_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.494807", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012023_PE2 base=S012023_PE2", "timestamp": "2025-09-04T20:20:28.495077", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012023_PE2", "timestamp": "2025-09-04T20:20:28.495511", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012023_PE2: conveyor=S012023_PE2_VFD1.CTRL parent_fault=S012023_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012023_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.496873", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012023_PE3 base=S012023_PE3", "timestamp": "2025-09-04T20:20:28.497135", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012023_PE3", "timestamp": "2025-09-04T20:20:28.497578", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012023_PE3: conveyor=S012023_PE3_VFD1.CTRL parent_fault=S012023_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012023_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.498895", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012027_PE1 base=S012027_PE1", "timestamp": "2025-09-04T20:20:28.499159", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012027_PE1", "timestamp": "2025-09-04T20:20:28.499548", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012027_PE1: conveyor=S012027_PE1_VFD1.CTRL parent_fault=S012027_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012027_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.500920", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012027_PE2 base=S012027_PE2", "timestamp": "2025-09-04T20:20:28.501180", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012027_PE2", "timestamp": "2025-09-04T20:20:28.501586", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012027_PE2: conveyor=S012027_PE2_VFD1.CTRL parent_fault=S012027_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012027_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.502916", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012027_PE3 base=S012027_PE3", "timestamp": "2025-09-04T20:20:28.503191", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012027_PE3", "timestamp": "2025-09-04T20:20:28.503614", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012027_PE3: conveyor=S012027_PE3_VFD1.CTRL parent_fault=S012027_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012027_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.504884", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012029_PE1 base=S012029_PE1", "timestamp": "2025-09-04T20:20:28.505145", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012029_PE1", "timestamp": "2025-09-04T20:20:28.505555", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012029_PE1: conveyor=S012029_PE1_VFD1.CTRL parent_fault=S012029_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012029_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.506766", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012029_PE2 base=S012029_PE2", "timestamp": "2025-09-04T20:20:28.507038", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012029_PE2", "timestamp": "2025-09-04T20:20:28.507503", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012029_PE2: conveyor=S012029_PE2_VFD1.CTRL parent_fault=S012029_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012029_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.508842", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012029_PE3 base=S012029_PE3", "timestamp": "2025-09-04T20:20:28.509086", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012029_PE3", "timestamp": "2025-09-04T20:20:28.509500", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012029_PE3: conveyor=S012029_PE3_VFD1.CTRL parent_fault=S012029_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012029_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.510736", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012028_PE1 base=S012028_PE1", "timestamp": "2025-09-04T20:20:28.511009", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012028_PE1", "timestamp": "2025-09-04T20:20:28.511446", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012028_PE1: conveyor=S012028_PE1_VFD1.CTRL parent_fault=S012028_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012028_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.512766", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012028_PE2 base=S012028_PE2", "timestamp": "2025-09-04T20:20:28.513011", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012028_PE2", "timestamp": "2025-09-04T20:20:28.513457", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012028_PE2: conveyor=S012028_PE2_VFD1.CTRL parent_fault=S012028_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012028_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.514696", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012028_PE3 base=S012028_PE3", "timestamp": "2025-09-04T20:20:28.514956", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012028_PE3", "timestamp": "2025-09-04T20:20:28.515377", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012028_PE3: conveyor=S012028_PE3_VFD1.CTRL parent_fault=S012028_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012028_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.516815", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012030_PE1 base=S012030_PE1", "timestamp": "2025-09-04T20:20:28.517053", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012030_PE1", "timestamp": "2025-09-04T20:20:28.517448", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012030_PE1: conveyor=S012030_PE1_VFD1.CTRL parent_fault=S012030_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012030_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.518789", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012030_PE2 base=S012030_PE2", "timestamp": "2025-09-04T20:20:28.519055", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012030_PE2", "timestamp": "2025-09-04T20:20:28.519471", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012030_PE2: conveyor=S012030_PE2_VFD1.CTRL parent_fault=S012030_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012030_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.520684", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012030_PE3 base=S012030_PE3", "timestamp": "2025-09-04T20:20:28.520944", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012030_PE3", "timestamp": "2025-09-04T20:20:28.521386", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012030_PE3: conveyor=S012030_PE3_VFD1.CTRL parent_fault=S012030_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012030_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.522649", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012026_PE1 base=S012026_PE1", "timestamp": "2025-09-04T20:20:28.522907", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012026_PE1", "timestamp": "2025-09-04T20:20:28.523329", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012026_PE1: conveyor=S012026_PE1_VFD1.CTRL parent_fault=S012026_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012026_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.524641", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012026_PE2 base=S012026_PE2", "timestamp": "2025-09-04T20:20:28.524920", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012026_PE2", "timestamp": "2025-09-04T20:20:28.525360", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012026_PE2: conveyor=S012026_PE2_VFD1.CTRL parent_fault=S012026_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012026_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.526603", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012026_PE3 base=S012026_PE3", "timestamp": "2025-09-04T20:20:28.526859", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012026_PE3", "timestamp": "2025-09-04T20:20:28.527289", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012026_PE3: conveyor=S012026_PE3_VFD1.CTRL parent_fault=S012026_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012026_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.528520", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012024_PE1 base=S012024_PE1", "timestamp": "2025-09-04T20:20:28.528772", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012024_PE1", "timestamp": "2025-09-04T20:20:28.529191", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012024_PE1: conveyor=S012024_PE1_VFD1.CTRL parent_fault=S012024_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012024_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.530455", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012024_PE2 base=S012024_PE2", "timestamp": "2025-09-04T20:20:28.530717", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012024_PE2", "timestamp": "2025-09-04T20:20:28.531150", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012024_PE2: conveyor=S012024_PE2_VFD1.CTRL parent_fault=S012024_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012024_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.532441", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012024_PE3 base=S012024_PE3", "timestamp": "2025-09-04T20:20:28.532733", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012024_PE3", "timestamp": "2025-09-04T20:20:28.533525", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012024_PE3: conveyor=S012024_PE3_VFD1.CTRL parent_fault=S012024_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012024_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.535035", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012033_PE1 base=S012033_PE1", "timestamp": "2025-09-04T20:20:28.535330", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012033_PE1", "timestamp": "2025-09-04T20:20:28.535770", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012033_PE1: conveyor=S012033_PE1_VFD1.CTRL parent_fault=S012033_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012033_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.536965", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012033_PE2 base=S012033_PE2", "timestamp": "2025-09-04T20:20:28.537213", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012033_PE2", "timestamp": "2025-09-04T20:20:28.537629", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012033_PE2: conveyor=S012033_PE2_VFD1.CTRL parent_fault=S012033_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012033_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.538862", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012033_PE3 base=S012033_PE3", "timestamp": "2025-09-04T20:20:28.539111", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012033_PE3", "timestamp": "2025-09-04T20:20:28.539576", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012033_PE3: conveyor=S012033_PE3_VFD1.CTRL parent_fault=S012033_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012033_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.540968", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012031_PE1 base=S012031_PE1", "timestamp": "2025-09-04T20:20:28.541229", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012031_PE1", "timestamp": "2025-09-04T20:20:28.541677", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012031_PE1: conveyor=S012031_PE1_VFD1.CTRL parent_fault=S012031_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012031_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.543000", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012031_PE2 base=S012031_PE2", "timestamp": "2025-09-04T20:20:28.543265", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012031_PE2", "timestamp": "2025-09-04T20:20:28.543679", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012031_PE2: conveyor=S012031_PE2_VFD1.CTRL parent_fault=S012031_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012031_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.545046", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012031_PE3 base=S012031_PE3", "timestamp": "2025-09-04T20:20:28.545305", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012031_PE3", "timestamp": "2025-09-04T20:20:28.545749", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012031_PE3: conveyor=S012031_PE3_VFD1.CTRL parent_fault=S012031_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012031_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.547014", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012035_PE1 base=S012035_PE1", "timestamp": "2025-09-04T20:20:28.547314", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012035_PE1", "timestamp": "2025-09-04T20:20:28.547748", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012035_PE1: conveyor=S012035_PE1_VFD1.CTRL parent_fault=S012035_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012035_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.549001", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012035_PE2 base=S012035_PE2", "timestamp": "2025-09-04T20:20:28.549279", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012035_PE2", "timestamp": "2025-09-04T20:20:28.549685", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012035_PE2: conveyor=S012035_PE2_VFD1.CTRL parent_fault=S012035_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012035_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.550930", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012035_PE3 base=S012035_PE3", "timestamp": "2025-09-04T20:20:28.551186", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012035_PE3", "timestamp": "2025-09-04T20:20:28.551616", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012035_PE3: conveyor=S012035_PE3_VFD1.CTRL parent_fault=S012035_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012035_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.552893", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012037_PE1 base=S012037_PE1", "timestamp": "2025-09-04T20:20:28.553151", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012037_PE1", "timestamp": "2025-09-04T20:20:28.553583", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012037_PE1: conveyor=S012037_PE1_VFD1.CTRL parent_fault=S012037_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012037_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.554856", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012037_PE2 base=S012037_PE2", "timestamp": "2025-09-04T20:20:28.555129", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012037_PE2", "timestamp": "2025-09-04T20:20:28.555715", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012037_PE2: conveyor=S012037_PE2_VFD1.CTRL parent_fault=S012037_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012037_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.557172", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012037_PE3 base=S012037_PE3", "timestamp": "2025-09-04T20:20:28.557460", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012037_PE3", "timestamp": "2025-09-04T20:20:28.558093", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012037_PE3: conveyor=S012037_PE3_VFD1.CTRL parent_fault=S012037_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012037_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.559368", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012036_PE1 base=S012036_PE1", "timestamp": "2025-09-04T20:20:28.559629", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012036_PE1", "timestamp": "2025-09-04T20:20:28.560079", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012036_PE1: conveyor=S012036_PE1_VFD1.CTRL parent_fault=S012036_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012036_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.561310", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012036_PE2 base=S012036_PE2", "timestamp": "2025-09-04T20:20:28.561559", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012036_PE2", "timestamp": "2025-09-04T20:20:28.562005", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012036_PE2: conveyor=S012036_PE2_VFD1.CTRL parent_fault=S012036_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012036_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.563339", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012036_PE3 base=S012036_PE3", "timestamp": "2025-09-04T20:20:28.563601", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012036_PE3", "timestamp": "2025-09-04T20:20:28.564116", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012036_PE3: conveyor=S012036_PE3_VFD1.CTRL parent_fault=S012036_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012036_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.565413", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012038_PE1 base=S012038_PE1", "timestamp": "2025-09-04T20:20:28.565676", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012038_PE1", "timestamp": "2025-09-04T20:20:28.566113", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012038_PE1: conveyor=S012038_PE1_VFD1.CTRL parent_fault=S012038_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012038_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.567366", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012038_PE2 base=S012038_PE2", "timestamp": "2025-09-04T20:20:28.567616", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012038_PE2", "timestamp": "2025-09-04T20:20:28.568058", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012038_PE2: conveyor=S012038_PE2_VFD1.CTRL parent_fault=S012038_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012038_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.569251", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012038_PE3 base=S012038_PE3", "timestamp": "2025-09-04T20:20:28.569573", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012038_PE3", "timestamp": "2025-09-04T20:20:28.569959", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012038_PE3: conveyor=S012038_PE3_VFD1.CTRL parent_fault=S012038_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012038_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.571147", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012034_PE1 base=S012034_PE1", "timestamp": "2025-09-04T20:20:28.571395", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012034_PE1", "timestamp": "2025-09-04T20:20:28.571780", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012034_PE1: conveyor=S012034_PE1_VFD1.CTRL parent_fault=S012034_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012034_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.573155", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012034_PE2 base=S012034_PE2", "timestamp": "2025-09-04T20:20:28.573451", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012034_PE2", "timestamp": "2025-09-04T20:20:28.574106", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012034_PE2: conveyor=S012034_PE2_VFD1.CTRL parent_fault=S012034_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012034_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.575531", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012034_PE3 base=S012034_PE3", "timestamp": "2025-09-04T20:20:28.575783", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012034_PE3", "timestamp": "2025-09-04T20:20:28.576215", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012034_PE3: conveyor=S012034_PE3_VFD1.CTRL parent_fault=S012034_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012034_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.577530", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012032_PE1 base=S012032_PE1", "timestamp": "2025-09-04T20:20:28.577774", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012032_PE1", "timestamp": "2025-09-04T20:20:28.578162", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012032_PE1: conveyor=S012032_PE1_VFD1.CTRL parent_fault=S012032_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012032_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.579387", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012032_PE2 base=S012032_PE2", "timestamp": "2025-09-04T20:20:28.579645", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012032_PE2", "timestamp": "2025-09-04T20:20:28.580144", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012032_PE2: conveyor=S012032_PE2_VFD1.CTRL parent_fault=S012032_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012032_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.581406", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S012032_PE3 base=S012032_PE3", "timestamp": "2025-09-04T20:20:28.581668", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S012032_PE3", "timestamp": "2025-09-04T20:20:28.582098", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S012032_PE3: conveyor=S012032_PE3_VFD1.CTRL parent_fault=S012032_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012032_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.583340", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013003_PE1 base=S013003_PE1", "timestamp": "2025-09-04T20:20:28.583608", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013003_PE1", "timestamp": "2025-09-04T20:20:28.584047", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013003_PE1: conveyor=S013003_PE1_VFD1.CTRL parent_fault=S013003_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013003_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.585261", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013003_PE2 base=S013003_PE2", "timestamp": "2025-09-04T20:20:28.585508", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013003_PE2", "timestamp": "2025-09-04T20:20:28.585933", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013003_PE2: conveyor=S013003_PE2_VFD1.CTRL parent_fault=S013003_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013003_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.587304", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013003_PE3 base=S013003_PE3", "timestamp": "2025-09-04T20:20:28.587567", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013003_PE3", "timestamp": "2025-09-04T20:20:28.588018", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013003_PE3: conveyor=S013003_PE3_VFD1.CTRL parent_fault=S013003_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013003_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.589295", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013001_PE1 base=S013001_PE1", "timestamp": "2025-09-04T20:20:28.589562", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013001_PE1", "timestamp": "2025-09-04T20:20:28.589993", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013001_PE1: conveyor=S013001_PE1_VFD1.CTRL parent_fault=S013001_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013001_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.591418", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013001_PE2 base=S013001_PE2", "timestamp": "2025-09-04T20:20:28.591673", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013001_PE2", "timestamp": "2025-09-04T20:20:28.592148", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013001_PE2: conveyor=S013001_PE2_VFD1.CTRL parent_fault=S013001_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013001_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.593388", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013001_PE3 base=S013001_PE3", "timestamp": "2025-09-04T20:20:28.593657", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013001_PE3", "timestamp": "2025-09-04T20:20:28.594101", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013001_PE3: conveyor=S013001_PE3_VFD1.CTRL parent_fault=S013001_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013001_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.595347", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013005_PE1 base=S013005_PE1", "timestamp": "2025-09-04T20:20:28.595829", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013005_PE1", "timestamp": "2025-09-04T20:20:28.596290", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013005_PE1: conveyor=S013005_PE1_VFD1.CTRL parent_fault=S013005_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013005_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.597643", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013005_PE2 base=S013005_PE2", "timestamp": "2025-09-04T20:20:28.597901", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013005_PE2", "timestamp": "2025-09-04T20:20:28.598329", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013005_PE2: conveyor=S013005_PE2_VFD1.CTRL parent_fault=S013005_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013005_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.599663", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013005_PE3 base=S013005_PE3", "timestamp": "2025-09-04T20:20:28.599921", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013005_PE3", "timestamp": "2025-09-04T20:20:28.600354", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013005_PE3: conveyor=S013005_PE3_VFD1.CTRL parent_fault=S013005_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013005_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.602076", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013007_PE1 base=S013007_PE1", "timestamp": "2025-09-04T20:20:28.602341", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013007_PE1", "timestamp": "2025-09-04T20:20:28.602751", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013007_PE1: conveyor=S013007_PE1_VFD1.CTRL parent_fault=S013007_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013007_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.604099", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013007_PE2 base=S013007_PE2", "timestamp": "2025-09-04T20:20:28.604356", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013007_PE2", "timestamp": "2025-09-04T20:20:28.604786", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013007_PE2: conveyor=S013007_PE2_VFD1.CTRL parent_fault=S013007_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013007_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.606014", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013007_PE3 base=S013007_PE3", "timestamp": "2025-09-04T20:20:28.606260", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013007_PE3", "timestamp": "2025-09-04T20:20:28.606663", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013007_PE3: conveyor=S013007_PE3_VFD1.CTRL parent_fault=S013007_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013007_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.608189", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013038_PE1 base=S013038_PE1", "timestamp": "2025-09-04T20:20:28.608477", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013038_PE1", "timestamp": "2025-09-04T20:20:28.608939", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013038_PE1: conveyor=S013038_PE1_VFD1.CTRL parent_fault=S013038_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013038_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.610167", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013038_PE2 base=S013038_PE2", "timestamp": "2025-09-04T20:20:28.610430", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013038_PE2", "timestamp": "2025-09-04T20:20:28.610864", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013038_PE2: conveyor=S013038_PE2_VFD1.CTRL parent_fault=S013038_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013038_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.612335", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013038_PE3 base=S013038_PE3", "timestamp": "2025-09-04T20:20:28.612606", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013038_PE3", "timestamp": "2025-09-04T20:20:28.613059", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013038_PE3: conveyor=S013038_PE3_VFD1.CTRL parent_fault=S013038_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013038_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.614293", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013040_PE1 base=S013040_PE1", "timestamp": "2025-09-04T20:20:28.614650", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013040_PE1", "timestamp": "2025-09-04T20:20:28.615056", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013040_PE1: conveyor=S013040_PE1_VFD1.CTRL parent_fault=S013040_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013040_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.616342", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013040_PE2 base=S013040_PE2", "timestamp": "2025-09-04T20:20:28.616600", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013040_PE2", "timestamp": "2025-09-04T20:20:28.617198", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013040_PE2: conveyor=S013040_PE2_VFD1.CTRL parent_fault=S013040_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013040_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.618547", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013040_PE3 base=S013040_PE3", "timestamp": "2025-09-04T20:20:28.618833", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013040_PE3", "timestamp": "2025-09-04T20:20:28.619272", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013040_PE3: conveyor=S013040_PE3_VFD1.CTRL parent_fault=S013040_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013040_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.620585", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013036_PE1 base=S013036_PE1", "timestamp": "2025-09-04T20:20:28.620995", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013036_PE1", "timestamp": "2025-09-04T20:20:28.621435", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013036_PE1: conveyor=S013036_PE1_VFD1.CTRL parent_fault=S013036_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013036_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.622687", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013036_PE2 base=S013036_PE2", "timestamp": "2025-09-04T20:20:28.622933", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013036_PE2", "timestamp": "2025-09-04T20:20:28.623369", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013036_PE2: conveyor=S013036_PE2_VFD1.CTRL parent_fault=S013036_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013036_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.624664", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013036_PE3 base=S013036_PE3", "timestamp": "2025-09-04T20:20:28.624936", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013036_PE3", "timestamp": "2025-09-04T20:20:28.625389", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013036_PE3: conveyor=S013036_PE3_VFD1.CTRL parent_fault=S013036_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013036_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.626688", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013034_PE1 base=S013034_PE1", "timestamp": "2025-09-04T20:20:28.626945", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013034_PE1", "timestamp": "2025-09-04T20:20:28.627398", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013034_PE1: conveyor=S013034_PE1_VFD1.CTRL parent_fault=S013034_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013034_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.628748", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013034_PE2 base=S013034_PE2", "timestamp": "2025-09-04T20:20:28.629012", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013034_PE2", "timestamp": "2025-09-04T20:20:28.629493", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013034_PE2: conveyor=S013034_PE2_VFD1.CTRL parent_fault=S013034_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013034_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.630935", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013034_PE3 base=S013034_PE3", "timestamp": "2025-09-04T20:20:28.631206", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013034_PE3", "timestamp": "2025-09-04T20:20:28.631783", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013034_PE3: conveyor=S013034_PE3_VFD1.CTRL parent_fault=S013034_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013034_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.633137", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013043_PE1 base=S013043_PE1", "timestamp": "2025-09-04T20:20:28.633397", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013043_PE1", "timestamp": "2025-09-04T20:20:28.633836", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013043_PE1: conveyor=S013043_PE1_VFD1.CTRL parent_fault=S013043_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013043_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.635107", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013043_PE2 base=S013043_PE2", "timestamp": "2025-09-04T20:20:28.635395", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013043_PE2", "timestamp": "2025-09-04T20:20:28.635832", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013043_PE2: conveyor=S013043_PE2_VFD1.CTRL parent_fault=S013043_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013043_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.637085", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013043_PE3 base=S013043_PE3", "timestamp": "2025-09-04T20:20:28.637352", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013043_PE3", "timestamp": "2025-09-04T20:20:28.637799", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013043_PE3: conveyor=S013043_PE3_VFD1.CTRL parent_fault=S013043_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013043_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.639085", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013041_PE1 base=S013041_PE1", "timestamp": "2025-09-04T20:20:28.639354", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013041_PE1", "timestamp": "2025-09-04T20:20:28.639778", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013041_PE1: conveyor=S013041_PE1_VFD1.CTRL parent_fault=S013041_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013041_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.641030", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013041_PE2 base=S013041_PE2", "timestamp": "2025-09-04T20:20:28.641304", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013041_PE2", "timestamp": "2025-09-04T20:20:28.641739", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013041_PE2: conveyor=S013041_PE2_VFD1.CTRL parent_fault=S013041_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013041_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.643162", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013041_PE3 base=S013041_PE3", "timestamp": "2025-09-04T20:20:28.643476", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013041_PE3", "timestamp": "2025-09-04T20:20:28.643920", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013041_PE3: conveyor=S013041_PE3_VFD1.CTRL parent_fault=S013041_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013041_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.645198", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013045_PE1 base=S013045_PE1", "timestamp": "2025-09-04T20:20:28.645449", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013045_PE1", "timestamp": "2025-09-04T20:20:28.645867", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013045_PE1: conveyor=S013045_PE1_VFD1.CTRL parent_fault=S013045_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013045_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.647108", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013045_PE2 base=S013045_PE2", "timestamp": "2025-09-04T20:20:28.647374", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013045_PE2", "timestamp": "2025-09-04T20:20:28.647794", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013045_PE2: conveyor=S013045_PE2_VFD1.CTRL parent_fault=S013045_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013045_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.649108", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013045_PE3 base=S013045_PE3", "timestamp": "2025-09-04T20:20:28.649366", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013045_PE3", "timestamp": "2025-09-04T20:20:28.649838", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013045_PE3: conveyor=S013045_PE3_VFD1.CTRL parent_fault=S013045_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013045_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.651099", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013047_PE1 base=S013047_PE1", "timestamp": "2025-09-04T20:20:28.651368", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013047_PE1", "timestamp": "2025-09-04T20:20:28.651806", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013047_PE1: conveyor=S013047_PE1_VFD1.CTRL parent_fault=S013047_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013047_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.653075", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013047_PE2 base=S013047_PE2", "timestamp": "2025-09-04T20:20:28.653349", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013047_PE2", "timestamp": "2025-09-04T20:20:28.653793", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013047_PE2: conveyor=S013047_PE2_VFD1.CTRL parent_fault=S013047_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013047_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.655054", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013047_PE3 base=S013047_PE3", "timestamp": "2025-09-04T20:20:28.655325", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013047_PE3", "timestamp": "2025-09-04T20:20:28.655745", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013047_PE3: conveyor=S013047_PE3_VFD1.CTRL parent_fault=S013047_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013047_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.657018", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013048_PE1 base=S013048_PE1", "timestamp": "2025-09-04T20:20:28.657512", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013048_PE1", "timestamp": "2025-09-04T20:20:28.657967", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013048_PE1: conveyor=S013048_PE1_VFD1.CTRL parent_fault=S013048_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013048_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.659487", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013048_PE2 base=S013048_PE2", "timestamp": "2025-09-04T20:20:28.659754", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013048_PE2", "timestamp": "2025-09-04T20:20:28.660213", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013048_PE2: conveyor=S013048_PE2_VFD1.CTRL parent_fault=S013048_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013048_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.661533", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013048_PE3 base=S013048_PE3", "timestamp": "2025-09-04T20:20:28.661800", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013048_PE3", "timestamp": "2025-09-04T20:20:28.662226", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013048_PE3: conveyor=S013048_PE3_VFD1.CTRL parent_fault=S013048_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013048_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.663551", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013044_PE1 base=S013044_PE1", "timestamp": "2025-09-04T20:20:28.663819", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013044_PE1", "timestamp": "2025-09-04T20:20:28.664269", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013044_PE1: conveyor=S013044_PE1_VFD1.CTRL parent_fault=S013044_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013044_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.665527", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013044_PE2 base=S013044_PE2", "timestamp": "2025-09-04T20:20:28.665793", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013044_PE2", "timestamp": "2025-09-04T20:20:28.666230", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013044_PE2: conveyor=S013044_PE2_VFD1.CTRL parent_fault=S013044_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013044_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.667453", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013044_PE3 base=S013044_PE3", "timestamp": "2025-09-04T20:20:28.667714", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013044_PE3", "timestamp": "2025-09-04T20:20:28.668180", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013044_PE3: conveyor=S013044_PE3_VFD1.CTRL parent_fault=S013044_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013044_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.669511", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013042_PE1 base=S013042_PE1", "timestamp": "2025-09-04T20:20:28.669786", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013042_PE1", "timestamp": "2025-09-04T20:20:28.670228", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013042_PE1: conveyor=S013042_PE1_VFD1.CTRL parent_fault=S013042_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013042_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.671438", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013042_PE2 base=S013042_PE2", "timestamp": "2025-09-04T20:20:28.671677", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013042_PE2", "timestamp": "2025-09-04T20:20:28.672108", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013042_PE2: conveyor=S013042_PE2_VFD1.CTRL parent_fault=S013042_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013042_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.674708", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013042_PE3 base=S013042_PE3", "timestamp": "2025-09-04T20:20:28.675053", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013042_PE3", "timestamp": "2025-09-04T20:20:28.675517", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013042_PE3: conveyor=S013042_PE3_VFD1.CTRL parent_fault=S013042_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013042_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.676843", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013051_PE1 base=S013051_PE1", "timestamp": "2025-09-04T20:20:28.677100", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013051_PE1", "timestamp": "2025-09-04T20:20:28.677524", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013051_PE1: conveyor=S013051_PE1_VFD1.CTRL parent_fault=S013051_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013051_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.678805", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013051_PE2 base=S013051_PE2", "timestamp": "2025-09-04T20:20:28.679069", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013051_PE2", "timestamp": "2025-09-04T20:20:28.679511", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013051_PE2: conveyor=S013051_PE2_VFD1.CTRL parent_fault=S013051_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013051_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.680800", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013051_PE3 base=S013051_PE3", "timestamp": "2025-09-04T20:20:28.681061", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013051_PE3", "timestamp": "2025-09-04T20:20:28.681503", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013051_PE3: conveyor=S013051_PE3_VFD1.CTRL parent_fault=S013051_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013051_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.682782", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013049_PE1 base=S013049_PE1", "timestamp": "2025-09-04T20:20:28.683036", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013049_PE1", "timestamp": "2025-09-04T20:20:28.683438", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013049_PE1: conveyor=S013049_PE1_VFD1.CTRL parent_fault=S013049_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013049_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.684636", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013049_PE2 base=S013049_PE2", "timestamp": "2025-09-04T20:20:28.684938", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013049_PE2", "timestamp": "2025-09-04T20:20:28.685369", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013049_PE2: conveyor=S013049_PE2_VFD1.CTRL parent_fault=S013049_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013049_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.686564", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013049_PE3 base=S013049_PE3", "timestamp": "2025-09-04T20:20:28.686792", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013049_PE3", "timestamp": "2025-09-04T20:20:28.687152", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013049_PE3: conveyor=S013049_PE3_VFD1.CTRL parent_fault=S013049_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013049_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.688538", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013053_PE1 base=S013053_PE1", "timestamp": "2025-09-04T20:20:28.688773", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013053_PE1", "timestamp": "2025-09-04T20:20:28.689196", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013053_PE1: conveyor=S013053_PE1_VFD1.CTRL parent_fault=S013053_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013053_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.690478", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013053_PE2 base=S013053_PE2", "timestamp": "2025-09-04T20:20:28.690733", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013053_PE2", "timestamp": "2025-09-04T20:20:28.691141", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013053_PE2: conveyor=S013053_PE2_VFD1.CTRL parent_fault=S013053_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013053_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.692488", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013053_PE3 base=S013053_PE3", "timestamp": "2025-09-04T20:20:28.692736", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013053_PE3", "timestamp": "2025-09-04T20:20:28.693133", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013053_PE3: conveyor=S013053_PE3_VFD1.CTRL parent_fault=S013053_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013053_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.694493", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013055_PE1 base=S013055_PE1", "timestamp": "2025-09-04T20:20:28.694746", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013055_PE1", "timestamp": "2025-09-04T20:20:28.695119", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013055_PE1: conveyor=S013055_PE1_VFD1.CTRL parent_fault=S013055_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013055_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.696294", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013055_PE2 base=S013055_PE2", "timestamp": "2025-09-04T20:20:28.696516", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013055_PE2", "timestamp": "2025-09-04T20:20:28.696894", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013055_PE2: conveyor=S013055_PE2_VFD1.CTRL parent_fault=S013055_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013055_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.698030", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013055_PE3 base=S013055_PE3", "timestamp": "2025-09-04T20:20:28.698289", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013055_PE3", "timestamp": "2025-09-04T20:20:28.698723", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013055_PE3: conveyor=S013055_PE3_VFD1.CTRL parent_fault=S013055_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013055_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.700030", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013054_PE1 base=S013054_PE1", "timestamp": "2025-09-04T20:20:28.700303", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013054_PE1", "timestamp": "2025-09-04T20:20:28.700658", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013054_PE1: conveyor=S013054_PE1_VFD1.CTRL parent_fault=S013054_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013054_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.701837", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013054_PE2 base=S013054_PE2", "timestamp": "2025-09-04T20:20:28.702071", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013054_PE2", "timestamp": "2025-09-04T20:20:28.702439", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013054_PE2: conveyor=S013054_PE2_VFD1.CTRL parent_fault=S013054_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013054_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.703633", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013054_PE3 base=S013054_PE3", "timestamp": "2025-09-04T20:20:28.703926", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013054_PE3", "timestamp": "2025-09-04T20:20:28.704356", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013054_PE3: conveyor=S013054_PE3_VFD1.CTRL parent_fault=S013054_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013054_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.705649", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013056_PE1 base=S013056_PE1", "timestamp": "2025-09-04T20:20:28.705889", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013056_PE1", "timestamp": "2025-09-04T20:20:28.706254", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013056_PE1: conveyor=S013056_PE1_VFD1.CTRL parent_fault=S013056_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013056_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.707394", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013056_PE2 base=S013056_PE2", "timestamp": "2025-09-04T20:20:28.707646", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013056_PE2", "timestamp": "2025-09-04T20:20:28.708141", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013056_PE2: conveyor=S013056_PE2_VFD1.CTRL parent_fault=S013056_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013056_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.709394", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013056_PE3 base=S013056_PE3", "timestamp": "2025-09-04T20:20:28.709692", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013056_PE3", "timestamp": "2025-09-04T20:20:28.710100", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013056_PE3: conveyor=S013056_PE3_VFD1.CTRL parent_fault=S013056_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013056_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.711296", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013052_PE1 base=S013052_PE1", "timestamp": "2025-09-04T20:20:28.711512", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013052_PE1", "timestamp": "2025-09-04T20:20:28.711923", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013052_PE1: conveyor=S013052_PE1_VFD1.CTRL parent_fault=S013052_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013052_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.713124", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013052_PE2 base=S013052_PE2", "timestamp": "2025-09-04T20:20:28.713372", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013052_PE2", "timestamp": "2025-09-04T20:20:28.713721", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013052_PE2: conveyor=S013052_PE2_VFD1.CTRL parent_fault=S013052_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013052_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.715032", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013052_PE3 base=S013052_PE3", "timestamp": "2025-09-04T20:20:28.715316", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013052_PE3", "timestamp": "2025-09-04T20:20:28.715659", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013052_PE3: conveyor=S013052_PE3_VFD1.CTRL parent_fault=S013052_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013052_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.716856", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013050_PE1 base=S013050_PE1", "timestamp": "2025-09-04T20:20:28.717102", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013050_PE1", "timestamp": "2025-09-04T20:20:28.717489", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013050_PE1: conveyor=S013050_PE1_VFD1.CTRL parent_fault=S013050_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013050_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.718715", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013050_PE2 base=S013050_PE2", "timestamp": "2025-09-04T20:20:28.718949", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013050_PE2", "timestamp": "2025-09-04T20:20:28.719464", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013050_PE2: conveyor=S013050_PE2_VFD1.CTRL parent_fault=S013050_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013050_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.720752", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013050_PE3 base=S013050_PE3", "timestamp": "2025-09-04T20:20:28.721040", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013050_PE3", "timestamp": "2025-09-04T20:20:28.721418", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013050_PE3: conveyor=S013050_PE3_VFD1.CTRL parent_fault=S013050_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013050_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.722742", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013059_PE1 base=S013059_PE1", "timestamp": "2025-09-04T20:20:28.723030", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013059_PE1", "timestamp": "2025-09-04T20:20:28.723408", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013059_PE1: conveyor=S013059_PE1_VFD1.CTRL parent_fault=S013059_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013059_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.724617", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013059_PE2 base=S013059_PE2", "timestamp": "2025-09-04T20:20:28.724869", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013059_PE2", "timestamp": "2025-09-04T20:20:28.725286", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013059_PE2: conveyor=S013059_PE2_VFD1.CTRL parent_fault=S013059_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013059_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.726532", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013059_PE3 base=S013059_PE3", "timestamp": "2025-09-04T20:20:28.726812", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013059_PE3", "timestamp": "2025-09-04T20:20:28.727200", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013059_PE3: conveyor=S013059_PE3_VFD1.CTRL parent_fault=S013059_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013059_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.728399", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013057_PE1 base=S013057_PE1", "timestamp": "2025-09-04T20:20:28.728619", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013057_PE1", "timestamp": "2025-09-04T20:20:28.728985", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013057_PE1: conveyor=S013057_PE1_VFD1.CTRL parent_fault=S013057_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013057_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.730195", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013057_PE2 base=S013057_PE2", "timestamp": "2025-09-04T20:20:28.730449", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013057_PE2", "timestamp": "2025-09-04T20:20:28.730778", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013057_PE2: conveyor=S013057_PE2_VFD1.CTRL parent_fault=S013057_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013057_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.731929", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013057_PE3 base=S013057_PE3", "timestamp": "2025-09-04T20:20:28.732238", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013057_PE3", "timestamp": "2025-09-04T20:20:28.732588", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013057_PE3: conveyor=S013057_PE3_VFD1.CTRL parent_fault=S013057_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013057_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.733742", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013061_PE1 base=S013061_PE1", "timestamp": "2025-09-04T20:20:28.734031", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013061_PE1", "timestamp": "2025-09-04T20:20:28.734422", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013061_PE1: conveyor=S013061_PE1_VFD1.CTRL parent_fault=S013061_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013061_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.735643", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013061_PE2 base=S013061_PE2", "timestamp": "2025-09-04T20:20:28.735863", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013061_PE2", "timestamp": "2025-09-04T20:20:28.736236", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013061_PE2: conveyor=S013061_PE2_VFD1.CTRL parent_fault=S013061_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013061_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.737430", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013061_PE3 base=S013061_PE3", "timestamp": "2025-09-04T20:20:28.737642", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013061_PE3", "timestamp": "2025-09-04T20:20:28.738036", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013061_PE3: conveyor=S013061_PE3_VFD1.CTRL parent_fault=S013061_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013061_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.739208", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013063_PE1 base=S013063_PE1", "timestamp": "2025-09-04T20:20:28.739452", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013063_PE1", "timestamp": "2025-09-04T20:20:28.739792", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013063_PE1: conveyor=S013063_PE1_VFD1.CTRL parent_fault=S013063_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013063_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.741920", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013063_PE2 base=S013063_PE2", "timestamp": "2025-09-04T20:20:28.742227", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013063_PE2", "timestamp": "2025-09-04T20:20:28.742651", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013063_PE2: conveyor=S013063_PE2_VFD1.CTRL parent_fault=S013063_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013063_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.743942", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013063_PE3 base=S013063_PE3", "timestamp": "2025-09-04T20:20:28.744227", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013063_PE3", "timestamp": "2025-09-04T20:20:28.744586", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013063_PE3: conveyor=S013063_PE3_VFD1.CTRL parent_fault=S013063_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013063_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.745748", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013062_PE1 base=S013062_PE1", "timestamp": "2025-09-04T20:20:28.746047", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013062_PE1", "timestamp": "2025-09-04T20:20:28.746512", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013062_PE1: conveyor=S013062_PE1_VFD1.CTRL parent_fault=S013062_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013062_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.747766", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013062_PE2 base=S013062_PE2", "timestamp": "2025-09-04T20:20:28.748018", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013062_PE2", "timestamp": "2025-09-04T20:20:28.748411", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013062_PE2: conveyor=S013062_PE2_VFD1.CTRL parent_fault=S013062_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013062_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.749571", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013062_PE3 base=S013062_PE3", "timestamp": "2025-09-04T20:20:28.749830", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013062_PE3", "timestamp": "2025-09-04T20:20:28.750217", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013062_PE3: conveyor=S013062_PE3_VFD1.CTRL parent_fault=S013062_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013062_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.751490", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013064_PE1 base=S013064_PE1", "timestamp": "2025-09-04T20:20:28.751720", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013064_PE1", "timestamp": "2025-09-04T20:20:28.752101", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013064_PE1: conveyor=S013064_PE1_VFD1.CTRL parent_fault=S013064_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013064_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.753318", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013064_PE2 base=S013064_PE2", "timestamp": "2025-09-04T20:20:28.753578", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013064_PE2", "timestamp": "2025-09-04T20:20:28.753947", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013064_PE2: conveyor=S013064_PE2_VFD1.CTRL parent_fault=S013064_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013064_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.755195", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013064_PE3 base=S013064_PE3", "timestamp": "2025-09-04T20:20:28.755450", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013064_PE3", "timestamp": "2025-09-04T20:20:28.755893", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013064_PE3: conveyor=S013064_PE3_VFD1.CTRL parent_fault=S013064_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013064_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.757268", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013058_PE1 base=S013058_PE1", "timestamp": "2025-09-04T20:20:28.757552", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013058_PE1", "timestamp": "2025-09-04T20:20:28.758146", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013058_PE1: conveyor=S013058_PE1_VFD1.CTRL parent_fault=S013058_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013058_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.759384", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013058_PE2 base=S013058_PE2", "timestamp": "2025-09-04T20:20:28.759651", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013058_PE2", "timestamp": "2025-09-04T20:20:28.760023", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013058_PE2: conveyor=S013058_PE2_VFD1.CTRL parent_fault=S013058_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013058_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.761228", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013058_PE3 base=S013058_PE3", "timestamp": "2025-09-04T20:20:28.761471", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013058_PE3", "timestamp": "2025-09-04T20:20:28.761846", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013058_PE3: conveyor=S013058_PE3_VFD1.CTRL parent_fault=S013058_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013058_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.763170", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013006_PE1 base=S013006_PE1", "timestamp": "2025-09-04T20:20:28.763468", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013006_PE1", "timestamp": "2025-09-04T20:20:28.763839", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013006_PE1: conveyor=S013006_PE1_VFD1.CTRL parent_fault=S013006_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013006_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.765099", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013006_PE2 base=S013006_PE2", "timestamp": "2025-09-04T20:20:28.765391", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013006_PE2", "timestamp": "2025-09-04T20:20:28.765731", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013006_PE2: conveyor=S013006_PE2_VFD1.CTRL parent_fault=S013006_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013006_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.767088", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013006_PE3 base=S013006_PE3", "timestamp": "2025-09-04T20:20:28.767357", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013006_PE3", "timestamp": "2025-09-04T20:20:28.767758", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013006_PE3: conveyor=S013006_PE3_VFD1.CTRL parent_fault=S013006_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013006_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.769092", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013008_PE1 base=S013008_PE1", "timestamp": "2025-09-04T20:20:28.769384", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013008_PE1", "timestamp": "2025-09-04T20:20:28.769796", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013008_PE1: conveyor=S013008_PE1_VFD1.CTRL parent_fault=S013008_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013008_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.770978", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013008_PE2 base=S013008_PE2", "timestamp": "2025-09-04T20:20:28.771248", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013008_PE2", "timestamp": "2025-09-04T20:20:28.771622", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013008_PE2: conveyor=S013008_PE2_VFD1.CTRL parent_fault=S013008_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013008_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.772835", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013008_PE3 base=S013008_PE3", "timestamp": "2025-09-04T20:20:28.773053", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013008_PE3", "timestamp": "2025-09-04T20:20:28.773658", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013008_PE3: conveyor=S013008_PE3_VFD1.CTRL parent_fault=S013008_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013008_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.775008", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013004_PE1 base=S013004_PE1", "timestamp": "2025-09-04T20:20:28.775262", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013004_PE1", "timestamp": "2025-09-04T20:20:28.775653", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013004_PE1: conveyor=S013004_PE1_VFD1.CTRL parent_fault=S013004_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013004_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.776854", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013004_PE2 base=S013004_PE2", "timestamp": "2025-09-04T20:20:28.777152", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013004_PE2", "timestamp": "2025-09-04T20:20:28.777541", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013004_PE2: conveyor=S013004_PE2_VFD1.CTRL parent_fault=S013004_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013004_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.778726", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013004_PE3 base=S013004_PE3", "timestamp": "2025-09-04T20:20:28.778992", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013004_PE3", "timestamp": "2025-09-04T20:20:28.779396", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013004_PE3: conveyor=S013004_PE3_VFD1.CTRL parent_fault=S013004_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013004_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.780720", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013011_PE1 base=S013011_PE1", "timestamp": "2025-09-04T20:20:28.780978", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013011_PE1", "timestamp": "2025-09-04T20:20:28.781363", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013011_PE1: conveyor=S013011_PE1_VFD1.CTRL parent_fault=S013011_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013011_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.782960", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013011_PE2 base=S013011_PE2", "timestamp": "2025-09-04T20:20:28.783194", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013011_PE2", "timestamp": "2025-09-04T20:20:28.783571", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013011_PE2: conveyor=S013011_PE2_VFD1.CTRL parent_fault=S013011_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013011_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.784856", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013011_PE3 base=S013011_PE3", "timestamp": "2025-09-04T20:20:28.785148", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013011_PE3", "timestamp": "2025-09-04T20:20:28.785532", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013011_PE3: conveyor=S013011_PE3_VFD1.CTRL parent_fault=S013011_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013011_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.786687", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013009_PE1 base=S013009_PE1", "timestamp": "2025-09-04T20:20:28.786936", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013009_PE1", "timestamp": "2025-09-04T20:20:28.787303", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013009_PE1: conveyor=S013009_PE1_VFD1.CTRL parent_fault=S013009_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013009_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.788510", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013009_PE2 base=S013009_PE2", "timestamp": "2025-09-04T20:20:28.788728", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013009_PE2", "timestamp": "2025-09-04T20:20:28.789109", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013009_PE2: conveyor=S013009_PE2_VFD1.CTRL parent_fault=S013009_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013009_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.790309", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013009_PE3 base=S013009_PE3", "timestamp": "2025-09-04T20:20:28.790557", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013009_PE3", "timestamp": "2025-09-04T20:20:28.791026", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013009_PE3: conveyor=S013009_PE3_VFD1.CTRL parent_fault=S013009_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013009_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.792279", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013013_PE1 base=S013013_PE1", "timestamp": "2025-09-04T20:20:28.792505", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013013_PE1", "timestamp": "2025-09-04T20:20:28.792848", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013013_PE1: conveyor=S013013_PE1_VFD1.CTRL parent_fault=S013013_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013013_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.793990", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013013_PE2 base=S013013_PE2", "timestamp": "2025-09-04T20:20:28.794275", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013013_PE2", "timestamp": "2025-09-04T20:20:28.794627", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013013_PE2: conveyor=S013013_PE2_VFD1.CTRL parent_fault=S013013_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013013_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.796080", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013013_PE3 base=S013013_PE3", "timestamp": "2025-09-04T20:20:28.796391", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013013_PE3", "timestamp": "2025-09-04T20:20:28.796815", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013013_PE3: conveyor=S013013_PE3_VFD1.CTRL parent_fault=S013013_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013013_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.798028", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013015_PE1 base=S013015_PE1", "timestamp": "2025-09-04T20:20:28.798650", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013015_PE1", "timestamp": "2025-09-04T20:20:28.799254", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013015_PE1: conveyor=S013015_PE1_VFD1.CTRL parent_fault=S013015_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013015_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.800503", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013015_PE2 base=S013015_PE2", "timestamp": "2025-09-04T20:20:28.800739", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013015_PE2", "timestamp": "2025-09-04T20:20:28.801102", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013015_PE2: conveyor=S013015_PE2_VFD1.CTRL parent_fault=S013015_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013015_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.802253", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013015_PE3 base=S013015_PE3", "timestamp": "2025-09-04T20:20:28.802507", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013015_PE3", "timestamp": "2025-09-04T20:20:28.802848", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013015_PE3: conveyor=S013015_PE3_VFD1.CTRL parent_fault=S013015_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013015_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.804092", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013014_PE1 base=S013014_PE1", "timestamp": "2025-09-04T20:20:28.804337", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013014_PE1", "timestamp": "2025-09-04T20:20:28.804784", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013014_PE1: conveyor=S013014_PE1_VFD1.CTRL parent_fault=S013014_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013014_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.806077", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013014_PE2 base=S013014_PE2", "timestamp": "2025-09-04T20:20:28.806300", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013014_PE2", "timestamp": "2025-09-04T20:20:28.806675", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013014_PE2: conveyor=S013014_PE2_VFD1.CTRL parent_fault=S013014_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013014_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.807885", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013014_PE3 base=S013014_PE3", "timestamp": "2025-09-04T20:20:28.808142", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013014_PE3", "timestamp": "2025-09-04T20:20:28.808505", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013014_PE3: conveyor=S013014_PE3_VFD1.CTRL parent_fault=S013014_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013014_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.809689", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013012_PE1 base=S013012_PE1", "timestamp": "2025-09-04T20:20:28.809951", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013012_PE1", "timestamp": "2025-09-04T20:20:28.810350", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013012_PE1: conveyor=S013012_PE1_VFD1.CTRL parent_fault=S013012_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013012_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.811514", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013012_PE2 base=S013012_PE2", "timestamp": "2025-09-04T20:20:28.811783", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013012_PE2", "timestamp": "2025-09-04T20:20:28.812160", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013012_PE2: conveyor=S013012_PE2_VFD1.CTRL parent_fault=S013012_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013012_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.813385", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013012_PE3 base=S013012_PE3", "timestamp": "2025-09-04T20:20:28.813590", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013012_PE3", "timestamp": "2025-09-04T20:20:28.813941", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013012_PE3: conveyor=S013012_PE3_VFD1.CTRL parent_fault=S013012_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013012_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.815100", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013010_PE1 base=S013010_PE1", "timestamp": "2025-09-04T20:20:28.815334", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013010_PE1", "timestamp": "2025-09-04T20:20:28.815697", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013010_PE1: conveyor=S013010_PE1_VFD1.CTRL parent_fault=S013010_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013010_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.816851", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013010_PE2 base=S013010_PE2", "timestamp": "2025-09-04T20:20:28.817072", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013010_PE2", "timestamp": "2025-09-04T20:20:28.817423", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013010_PE2: conveyor=S013010_PE2_VFD1.CTRL parent_fault=S013010_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013010_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.818562", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013010_PE3 base=S013010_PE3", "timestamp": "2025-09-04T20:20:28.818856", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013010_PE3", "timestamp": "2025-09-04T20:20:28.819275", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013010_PE3: conveyor=S013010_PE3_VFD1.CTRL parent_fault=S013010_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013010_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.820527", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013019_PE1 base=S013019_PE1", "timestamp": "2025-09-04T20:20:28.820746", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013019_PE1", "timestamp": "2025-09-04T20:20:28.821113", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013019_PE1: conveyor=S013019_PE1_VFD1.CTRL parent_fault=S013019_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013019_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.822396", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013019_PE2 base=S013019_PE2", "timestamp": "2025-09-04T20:20:28.822662", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013019_PE2", "timestamp": "2025-09-04T20:20:28.823061", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013019_PE2: conveyor=S013019_PE2_VFD1.CTRL parent_fault=S013019_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013019_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.824457", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013019_PE3 base=S013019_PE3", "timestamp": "2025-09-04T20:20:28.824720", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013019_PE3", "timestamp": "2025-09-04T20:20:28.825112", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013019_PE3: conveyor=S013019_PE3_VFD1.CTRL parent_fault=S013019_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013019_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.826294", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013017_PE1 base=S013017_PE1", "timestamp": "2025-09-04T20:20:28.826586", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013017_PE1", "timestamp": "2025-09-04T20:20:28.826939", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013017_PE1: conveyor=S013017_PE1_VFD1.CTRL parent_fault=S013017_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013017_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.828131", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013017_PE2 base=S013017_PE2", "timestamp": "2025-09-04T20:20:28.828383", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013017_PE2", "timestamp": "2025-09-04T20:20:28.828764", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013017_PE2: conveyor=S013017_PE2_VFD1.CTRL parent_fault=S013017_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013017_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.829963", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013017_PE3 base=S013017_PE3", "timestamp": "2025-09-04T20:20:28.830222", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013017_PE3", "timestamp": "2025-09-04T20:20:28.830623", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013017_PE3: conveyor=S013017_PE3_VFD1.CTRL parent_fault=S013017_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013017_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.831829", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013021_PE1 base=S013021_PE1", "timestamp": "2025-09-04T20:20:28.832072", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013021_PE1", "timestamp": "2025-09-04T20:20:28.832452", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013021_PE1: conveyor=S013021_PE1_VFD1.CTRL parent_fault=S013021_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013021_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.833614", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013021_PE2 base=S013021_PE2", "timestamp": "2025-09-04T20:20:28.833841", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013021_PE2", "timestamp": "2025-09-04T20:20:28.834199", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013021_PE2: conveyor=S013021_PE2_VFD1.CTRL parent_fault=S013021_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013021_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.835372", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013021_PE3 base=S013021_PE3", "timestamp": "2025-09-04T20:20:28.835613", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013021_PE3", "timestamp": "2025-09-04T20:20:28.836005", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013021_PE3: conveyor=S013021_PE3_VFD1.CTRL parent_fault=S013021_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013021_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.837294", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013023_PE1 base=S013023_PE1", "timestamp": "2025-09-04T20:20:28.837549", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013023_PE1", "timestamp": "2025-09-04T20:20:28.837901", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013023_PE1: conveyor=S013023_PE1_VFD1.CTRL parent_fault=S013023_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013023_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.839069", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013023_PE2 base=S013023_PE2", "timestamp": "2025-09-04T20:20:28.839323", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013023_PE2", "timestamp": "2025-09-04T20:20:28.839659", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013023_PE2: conveyor=S013023_PE2_VFD1.CTRL parent_fault=S013023_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013023_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.841027", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013023_PE3 base=S013023_PE3", "timestamp": "2025-09-04T20:20:28.841294", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013023_PE3", "timestamp": "2025-09-04T20:20:28.841683", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013023_PE3: conveyor=S013023_PE3_VFD1.CTRL parent_fault=S013023_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013023_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.842854", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013022_PE1 base=S013022_PE1", "timestamp": "2025-09-04T20:20:28.843067", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013022_PE1", "timestamp": "2025-09-04T20:20:28.843414", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013022_PE1: conveyor=S013022_PE1_VFD1.CTRL parent_fault=S013022_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013022_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.844586", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013022_PE2 base=S013022_PE2", "timestamp": "2025-09-04T20:20:28.844803", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013022_PE2", "timestamp": "2025-09-04T20:20:28.845148", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013022_PE2: conveyor=S013022_PE2_VFD1.CTRL parent_fault=S013022_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013022_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.846445", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013022_PE3 base=S013022_PE3", "timestamp": "2025-09-04T20:20:28.846777", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013022_PE3", "timestamp": "2025-09-04T20:20:28.847245", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013022_PE3: conveyor=S013022_PE3_VFD1.CTRL parent_fault=S013022_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013022_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.848665", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013024_PE1 base=S013024_PE1", "timestamp": "2025-09-04T20:20:28.849003", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013024_PE1", "timestamp": "2025-09-04T20:20:28.849459", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013024_PE1: conveyor=S013024_PE1_VFD1.CTRL parent_fault=S013024_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013024_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.851222", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013024_PE2 base=S013024_PE2", "timestamp": "2025-09-04T20:20:28.851482", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013024_PE2", "timestamp": "2025-09-04T20:20:28.852077", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013024_PE2: conveyor=S013024_PE2_VFD1.CTRL parent_fault=S013024_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013024_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.853819", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013024_PE3 base=S013024_PE3", "timestamp": "2025-09-04T20:20:28.854099", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013024_PE3", "timestamp": "2025-09-04T20:20:28.854797", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013024_PE3: conveyor=S013024_PE3_VFD1.CTRL parent_fault=S013024_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013024_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.856297", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013020_PE1 base=S013020_PE1", "timestamp": "2025-09-04T20:20:28.857002", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013020_PE1", "timestamp": "2025-09-04T20:20:28.857816", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013020_PE1: conveyor=S013020_PE1_VFD1.CTRL parent_fault=S013020_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013020_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.859324", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013020_PE2 base=S013020_PE2", "timestamp": "2025-09-04T20:20:28.859592", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013020_PE2", "timestamp": "2025-09-04T20:20:28.860051", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013020_PE2: conveyor=S013020_PE2_VFD1.CTRL parent_fault=S013020_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013020_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.861364", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013020_PE3 base=S013020_PE3", "timestamp": "2025-09-04T20:20:28.861636", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013020_PE3", "timestamp": "2025-09-04T20:20:28.862103", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013020_PE3: conveyor=S013020_PE3_VFD1.CTRL parent_fault=S013020_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013020_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.863408", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013018_PE1 base=S013018_PE1", "timestamp": "2025-09-04T20:20:28.863691", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013018_PE1", "timestamp": "2025-09-04T20:20:28.864144", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013018_PE1: conveyor=S013018_PE1_VFD1.CTRL parent_fault=S013018_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013018_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.865564", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013018_PE2 base=S013018_PE2", "timestamp": "2025-09-04T20:20:28.865840", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013018_PE2", "timestamp": "2025-09-04T20:20:28.866236", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013018_PE2: conveyor=S013018_PE2_VFD1.CTRL parent_fault=S013018_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013018_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.867604", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013018_PE3 base=S013018_PE3", "timestamp": "2025-09-04T20:20:28.867882", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013018_PE3", "timestamp": "2025-09-04T20:20:28.868394", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013018_PE3: conveyor=S013018_PE3_VFD1.CTRL parent_fault=S013018_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013018_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.869673", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013027_PE1 base=S013027_PE1", "timestamp": "2025-09-04T20:20:28.869952", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013027_PE1", "timestamp": "2025-09-04T20:20:28.870405", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013027_PE1: conveyor=S013027_PE1_VFD1.CTRL parent_fault=S013027_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013027_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.871680", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013027_PE2 base=S013027_PE2", "timestamp": "2025-09-04T20:20:28.871936", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013027_PE2", "timestamp": "2025-09-04T20:20:28.872373", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013027_PE2: conveyor=S013027_PE2_VFD1.CTRL parent_fault=S013027_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013027_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.873761", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013027_PE3 base=S013027_PE3", "timestamp": "2025-09-04T20:20:28.874056", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013027_PE3", "timestamp": "2025-09-04T20:20:28.874556", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013027_PE3: conveyor=S013027_PE3_VFD1.CTRL parent_fault=S013027_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013027_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.875846", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013025_PE1 base=S013025_PE1", "timestamp": "2025-09-04T20:20:28.876177", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013025_PE1", "timestamp": "2025-09-04T20:20:28.876745", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013025_PE1: conveyor=S013025_PE1_VFD1.CTRL parent_fault=S013025_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013025_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.878036", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013025_PE2 base=S013025_PE2", "timestamp": "2025-09-04T20:20:28.878410", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013025_PE2", "timestamp": "2025-09-04T20:20:28.878790", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013025_PE2: conveyor=S013025_PE2_VFD1.CTRL parent_fault=S013025_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013025_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.880178", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013025_PE3 base=S013025_PE3", "timestamp": "2025-09-04T20:20:28.880450", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013025_PE3", "timestamp": "2025-09-04T20:20:28.880837", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013025_PE3: conveyor=S013025_PE3_VFD1.CTRL parent_fault=S013025_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013025_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.882082", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013029_PE1 base=S013029_PE1", "timestamp": "2025-09-04T20:20:28.882394", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013029_PE1", "timestamp": "2025-09-04T20:20:28.882763", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013029_PE1: conveyor=S013029_PE1_VFD1.CTRL parent_fault=S013029_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013029_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.883971", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013029_PE2 base=S013029_PE2", "timestamp": "2025-09-04T20:20:28.884285", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013029_PE2", "timestamp": "2025-09-04T20:20:28.884698", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013029_PE2: conveyor=S013029_PE2_VFD1.CTRL parent_fault=S013029_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013029_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.885914", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013029_PE3 base=S013029_PE3", "timestamp": "2025-09-04T20:20:28.886220", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013029_PE3", "timestamp": "2025-09-04T20:20:28.886674", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013029_PE3: conveyor=S013029_PE3_VFD1.CTRL parent_fault=S013029_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013029_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.888125", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013031_PE1 base=S013031_PE1", "timestamp": "2025-09-04T20:20:28.888494", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013031_PE1", "timestamp": "2025-09-04T20:20:28.888871", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013031_PE1: conveyor=S013031_PE1_VFD1.CTRL parent_fault=S013031_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013031_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.890133", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013031_PE2 base=S013031_PE2", "timestamp": "2025-09-04T20:20:28.890514", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013031_PE2", "timestamp": "2025-09-04T20:20:28.890944", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013031_PE2: conveyor=S013031_PE2_VFD1.CTRL parent_fault=S013031_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013031_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.892407", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013031_PE3 base=S013031_PE3", "timestamp": "2025-09-04T20:20:28.892734", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013031_PE3", "timestamp": "2025-09-04T20:20:28.893176", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013031_PE3: conveyor=S013031_PE3_VFD1.CTRL parent_fault=S013031_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013031_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.894441", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013032_PE1 base=S013032_PE1", "timestamp": "2025-09-04T20:20:28.894774", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013032_PE1", "timestamp": "2025-09-04T20:20:28.895211", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013032_PE1: conveyor=S013032_PE1_VFD1.CTRL parent_fault=S013032_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013032_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.896467", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013032_PE2 base=S013032_PE2", "timestamp": "2025-09-04T20:20:28.896791", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013032_PE2", "timestamp": "2025-09-04T20:20:28.897223", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013032_PE2: conveyor=S013032_PE2_VFD1.CTRL parent_fault=S013032_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013032_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.898494", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013032_PE3 base=S013032_PE3", "timestamp": "2025-09-04T20:20:28.898737", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013032_PE3", "timestamp": "2025-09-04T20:20:28.899110", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013032_PE3: conveyor=S013032_PE3_VFD1.CTRL parent_fault=S013032_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013032_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.900336", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013028_PE1 base=S013028_PE1", "timestamp": "2025-09-04T20:20:28.900558", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013028_PE1", "timestamp": "2025-09-04T20:20:28.900921", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013028_PE1: conveyor=S013028_PE1_VFD1.CTRL parent_fault=S013028_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013028_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.902221", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013028_PE2 base=S013028_PE2", "timestamp": "2025-09-04T20:20:28.902449", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013028_PE2", "timestamp": "2025-09-04T20:20:28.902806", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013028_PE2: conveyor=S013028_PE2_VFD1.CTRL parent_fault=S013028_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013028_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.904026", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013028_PE3 base=S013028_PE3", "timestamp": "2025-09-04T20:20:28.904276", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013028_PE3", "timestamp": "2025-09-04T20:20:28.904649", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013028_PE3: conveyor=S013028_PE3_VFD1.CTRL parent_fault=S013028_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013028_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.905828", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013026_PE1 base=S013026_PE1", "timestamp": "2025-09-04T20:20:28.906069", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013026_PE1", "timestamp": "2025-09-04T20:20:28.906441", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013026_PE1: conveyor=S013026_PE1_VFD1.CTRL parent_fault=S013026_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013026_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.907949", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013026_PE2 base=S013026_PE2", "timestamp": "2025-09-04T20:20:28.908287", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013026_PE2", "timestamp": "2025-09-04T20:20:28.908696", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013026_PE2: conveyor=S013026_PE2_VFD1.CTRL parent_fault=S013026_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013026_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.909946", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013026_PE3 base=S013026_PE3", "timestamp": "2025-09-04T20:20:28.910163", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013026_PE3", "timestamp": "2025-09-04T20:20:28.910510", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013026_PE3: conveyor=S013026_PE3_VFD1.CTRL parent_fault=S013026_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013026_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.911667", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013035_PE1 base=S013035_PE1", "timestamp": "2025-09-04T20:20:28.911936", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013035_PE1", "timestamp": "2025-09-04T20:20:28.912301", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013035_PE1: conveyor=S013035_PE1_VFD1.CTRL parent_fault=S013035_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013035_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.913524", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013035_PE2 base=S013035_PE2", "timestamp": "2025-09-04T20:20:28.913739", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013035_PE2", "timestamp": "2025-09-04T20:20:28.914097", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013035_PE2: conveyor=S013035_PE2_VFD1.CTRL parent_fault=S013035_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013035_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.915267", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013035_PE3 base=S013035_PE3", "timestamp": "2025-09-04T20:20:28.915599", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013035_PE3", "timestamp": "2025-09-04T20:20:28.916137", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013035_PE3: conveyor=S013035_PE3_VFD1.CTRL parent_fault=S013035_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013035_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.917428", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013033_PE1 base=S013033_PE1", "timestamp": "2025-09-04T20:20:28.917741", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013033_PE1", "timestamp": "2025-09-04T20:20:28.918173", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013033_PE1: conveyor=S013033_PE1_VFD1.CTRL parent_fault=S013033_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013033_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.919401", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013033_PE2 base=S013033_PE2", "timestamp": "2025-09-04T20:20:28.919660", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013033_PE2", "timestamp": "2025-09-04T20:20:28.920050", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013033_PE2: conveyor=S013033_PE2_VFD1.CTRL parent_fault=S013033_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013033_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.921300", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013033_PE3 base=S013033_PE3", "timestamp": "2025-09-04T20:20:28.921572", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013033_PE3", "timestamp": "2025-09-04T20:20:28.921945", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013033_PE3: conveyor=S013033_PE3_VFD1.CTRL parent_fault=S013033_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013033_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.923340", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013037_PE1 base=S013037_PE1", "timestamp": "2025-09-04T20:20:28.923645", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013037_PE1", "timestamp": "2025-09-04T20:20:28.924125", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013037_PE1: conveyor=S013037_PE1_VFD1.CTRL parent_fault=S013037_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013037_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.925467", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013037_PE2 base=S013037_PE2", "timestamp": "2025-09-04T20:20:28.925692", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013037_PE2", "timestamp": "2025-09-04T20:20:28.926042", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013037_PE2: conveyor=S013037_PE2_VFD1.CTRL parent_fault=S013037_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013037_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.927284", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013037_PE3 base=S013037_PE3", "timestamp": "2025-09-04T20:20:28.927538", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013037_PE3", "timestamp": "2025-09-04T20:20:28.927908", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013037_PE3: conveyor=S013037_PE3_VFD1.CTRL parent_fault=S013037_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013037_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.929235", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013039_PE1 base=S013039_PE1", "timestamp": "2025-09-04T20:20:28.929579", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013039_PE1", "timestamp": "2025-09-04T20:20:28.930023", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013039_PE1: conveyor=S013039_PE1_VFD1.CTRL parent_fault=S013039_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013039_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.931341", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013039_PE2 base=S013039_PE2", "timestamp": "2025-09-04T20:20:28.931622", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013039_PE2", "timestamp": "2025-09-04T20:20:28.932073", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013039_PE2: conveyor=S013039_PE2_VFD1.CTRL parent_fault=S013039_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013039_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.933330", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE processing S013039_PE3 base=S013039_PE3", "timestamp": "2025-09-04T20:20:28.933636", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "No VFD found for S013039_PE3", "timestamp": "2025-09-04T20:20:28.934048", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "FPE S013039_PE3: conveyor=S013039_PE3_VFD1.CTRL parent_fault=S013039_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013039_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2", "timestamp": "2025-09-04T20:20:28.935457", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Data: FPE configs=351", "timestamp": "2025-09-04T20:20:28.935704", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Extracting PMM data", "timestamp": "2025-09-04T20:20:28.936045", "module": "DataLoader", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "data_extraction", "type": "PMM"}
|
|
{"level": "INFO", "message": "Data: PMM entries=0", "timestamp": "2025-09-04T20:20:28.937087", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Data: PMM configs=0", "timestamp": "2025-09-04T20:20:28.937279", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Extracting CB_MONITOR data", "timestamp": "2025-09-04T20:20:28.937418", "module": "DataLoader", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "data_extraction", "type": "CB_MONITOR"}
|
|
{"level": "INFO", "message": "Data: CB PDPs=0", "timestamp": "2025-09-04T20:20:28.938342", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Data: CB configs=0", "timestamp": "2025-09-04T20:20:28.938565", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Tags created: total=428 | standard=1 safety=3 dcs=1 modules=415", "timestamp": "2025-09-04T20:20:28.939086", "module": "src.writers.xml_tag_writer", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "summary"}
|
|
{"level": "INFO", "message": "Added 428 controller tags", "timestamp": "2025-09-04T20:20:28.939283", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Generating main program routines...", "timestamp": "2025-09-04T20:20:28.939427", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Generating routine: mcm", "timestamp": "2025-09-04T20:20:28.939585", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Successfully generated routine: mcm", "timestamp": "2025-09-04T20:20:28.939703", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Generating routine: rack", "timestamp": "2025-09-04T20:20:28.939820", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Successfully generated routine: rack", "timestamp": "2025-09-04T20:20:28.940046", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Generating routine: dpm", "timestamp": "2025-09-04T20:20:28.940328", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Successfully generated routine: dpm", "timestamp": "2025-09-04T20:20:28.941916", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Generating routine: fiom", "timestamp": "2025-09-04T20:20:28.942253", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Successfully generated routine: fiom", "timestamp": "2025-09-04T20:20:28.944329", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin fioh cannot generate with current data", "timestamp": "2025-09-04T20:20:28.944577", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin apf cannot generate with current data", "timestamp": "2025-09-04T20:20:28.945157", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin flow_ctrl cannot generate with current data", "timestamp": "2025-09-04T20:20:28.945538", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Extracting SPEED_CTRL data", "timestamp": "2025-09-04T20:20:28.945711", "module": "DataLoader", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "data_extraction", "type": "SPEED_CTRL"}
|
|
{"level": "INFO", "message": "Data: SPEED_CTRL VFDs=0", "timestamp": "2025-09-04T20:20:28.946138", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "SPEED_CTRL sample=", "timestamp": "2025-09-04T20:20:28.946374", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Data: SPEED_CTRL count=0", "timestamp": "2025-09-04T20:20:28.946521", "module": "DataLoader", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin speed_ctrl cannot generate with current data", "timestamp": "2025-09-04T20:20:28.946641", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin estop_check cannot generate with current data", "timestamp": "2025-09-04T20:20:28.946777", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin encoder cannot generate with current data", "timestamp": "2025-09-04T20:20:28.946896", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Generating routine: safety_tag_map", "timestamp": "2025-09-04T20:20:28.947010", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Safety tag map: RST data has 1 rows", "timestamp": "2025-09-04T20:20:28.947214", "module": "src.routines.safety_tag_map", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Added safety tag mapping: MCM05 -> Local:5:I.Data.0", "timestamp": "2025-09-04T20:20:28.947444", "module": "src.routines.safety_tag_map", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Safety tag map: Generating 1 rungs", "timestamp": "2025-09-04T20:20:28.947631", "module": "src.routines.safety_tag_map", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Generated rung 1: XIC(Local:5:I.Data.0)OTE(MCM05);", "timestamp": "2025-09-04T20:20:28.947759", "module": "src.routines.safety_tag_map", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Safety tag map: Generated 1 total rungs", "timestamp": "2025-09-04T20:20:28.947867", "module": "src.routines.safety_tag_map", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Successfully generated routine: safety_tag_map", "timestamp": "2025-09-04T20:20:28.947991", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Generating routine: station_jr_pb", "timestamp": "2025-09-04T20:20:28.948125", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Successfully generated routine: station_jr_pb", "timestamp": "2025-09-04T20:20:28.948628", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin station_s_pb cannot generate with current data", "timestamp": "2025-09-04T20:20:28.948792", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin station_ss_pb cannot generate with current data", "timestamp": "2025-09-04T20:20:28.948945", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin station_epc cannot generate with current data", "timestamp": "2025-09-04T20:20:28.949085", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin jpe cannot generate with current data", "timestamp": "2025-09-04T20:20:28.949224", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Generating routine: fpe", "timestamp": "2025-09-04T20:20:28.949355", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Successfully generated routine: fpe", "timestamp": "2025-09-04T20:20:28.953475", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin pmm cannot generate with current data", "timestamp": "2025-09-04T20:20:28.953856", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin cb_monitor cannot generate with current data", "timestamp": "2025-09-04T20:20:28.954044", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Plugin belt_tracking cannot generate with current data", "timestamp": "2025-09-04T20:20:28.954600", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Generating routine: main_routine", "timestamp": "2025-09-04T20:20:28.954775", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Generating MainRoutine with JSR calls", "timestamp": "2025-09-04T20:20:28.955018", "module": "src.routines.main_routine_plugin.MainRoutinePlugin", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Successfully generated MainRoutine", "timestamp": "2025-09-04T20:20:28.955364", "module": "src.routines.main_routine_plugin.MainRoutinePlugin", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Successfully generated routine: main_routine", "timestamp": "2025-09-04T20:20:28.955655", "module": "src.plugin_system", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Main routine generation results: {'mcm': True, 'rack': True, 'dpm': True, 'fiom': True, 'fioh': False, 'apf': False, 'flow_ctrl': False, 'speed_ctrl': False, 'estop_check': False, 'encoder': False, 'safety_tag_map': True, 'station_jr_pb': True, 'station_s_pb': False, 'station_ss_pb': False, 'station_epc': False, 'jpe': False, 'fpe': True, 'pmm': False, 'cb_monitor': False, 'belt_tracking': False, 'main_routine': True}", "timestamp": "2025-09-04T20:20:28.955904", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Routines created (8): MainRoutine, R010_MCM, R011_RACK, R020_DPM, R030_FIOM, R090_STATION_JR_PB, R101_FPE, R130_SAFETY_TAG_MAP", "timestamp": "2025-09-04T20:20:28.956107", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "summary"}
|
|
{"level": "INFO", "message": "- R010_MCM: 2 rungs | example: NOP();", "timestamp": "2025-09-04T20:20:28.956288", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "summary"}
|
|
{"level": "INFO", "message": "- R011_RACK: 2 rungs | example: NOP();", "timestamp": "2025-09-04T20:20:28.956413", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "summary"}
|
|
{"level": "INFO", "message": "- R020_DPM: 3 rungs | example: NOP();", "timestamp": "2025-09-04T20:20:28.956523", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "summary"}
|
|
{"level": "INFO", "message": "- R030_FIOM: 32 rungs | example: NOP();", "timestamp": "2025-09-04T20:20:28.956628", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "summary"}
|
|
{"level": "INFO", "message": "- R130_SAFETY_TAG_MAP: 2 rungs | example: XIC(Local:5:I.Data.0)OTE(MCM_S_PB);", "timestamp": "2025-09-04T20:20:28.956734", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "summary"}
|
|
{"level": "INFO", "message": "- R090_STATION_JR_PB: 31 rungs | example: AOI_STATION_JR_PB(S012001_JR1_PB.AOI,S012001_JR1_PB.HMI,S012001_JR1_PB.CTRL,NO_PARTNER,VS01B_FIOM1:I.Pt04.Data,VS01B_FIOM1:O.Pt05.Data,MCM.CTRL)MOVE(S012001_...", "timestamp": "2025-09-04T20:20:28.956876", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "summary"}
|
|
{"level": "INFO", "message": "- R101_FPE: 351 rungs | example: AOI_FPE(S012001_PE1.AOI,S012001_PE1.HMI,S012001_PE1.CTRL,S012001_PE1_VFD1.CTRL,S012001_PE1_VFD1:I.ConnectionFaulted,VS01B_FIOH1:I.ProcessDataIn.Connector_6_A...", "timestamp": "2025-09-04T20:20:28.957054", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "summary"}
|
|
{"level": "INFO", "message": "- MainRoutine: 1 rungs | example: [JSR(R010_MCM,0) ,JSR(R011_RACK,0) ,JSR(R020_DPM,0) ,JSR(R030_FIOM,0) ,JSR(R130_SAFETY_TAG_MAP,0) ,JSR(R090_STATION_JR_PB,0) ,JSR(R101_FPE,0) ];", "timestamp": "2025-09-04T20:20:28.957200", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "stage": "summary"}
|
|
{"level": "INFO", "message": "Successfully completed ModernMainProgramGenerator generation", "timestamp": "2025-09-04T20:20:28.957398", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Written ModernMainProgramGenerator to /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/generated_projects/SAT9_MCM05/MainProgram_Generated.L5X", "timestamp": "2025-09-04T20:20:28.966305", "module": "ModernMainProgramGenerator", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "[SUCCESS] MainProgram written to /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/generated_projects/SAT9_MCM05/MainProgram_Generated.L5X", "timestamp": "2025-09-04T20:20:28.966544", "module": "__main__", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "Generating safety tag mapping...", "timestamp": "2025-09-04T20:20:28.966738", "module": "__main__", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Creating MappingWriter wrapper", "timestamp": "2025-09-04T20:20:28.966905", "module": "src.container", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "DEBUG", "message": "Creating DataLoader instance", "timestamp": "2025-09-04T20:20:28.967070", "module": "src.container", "file": "logging_config.py", "line": 126, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py", "excel_file": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/DESC_IP_MERGED.xlsx"}
|
|
{"level": "INFO", "message": "[SUCCESS] Safety tag mapping written to /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/generated_projects/SAT9_MCM05/SafetyTagMapping.txt", "timestamp": "2025-09-04T20:20:29.041072", "module": "__main__", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": " - Safety tags: 1", "timestamp": "2025-09-04T20:20:29.041286", "module": "__main__", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
{"level": "INFO", "message": "=== All artifacts generated successfully! ===", "timestamp": "2025-09-04T20:20:29.041486", "module": "__main__", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
|
|
=== Step 2: Routines Generator stdout ===
|
|
[DEBUG] Found 0 SO beacon tags for safety mapping
|
|
Found STATION_JR_PB config for S012001_JR1_PB
|
|
Found STATION_JR_PB config for S012039_JR1_PB
|
|
Found STATION_JR_PB config for S012047_JR1_PB
|
|
Found STATION_JR_PB config for S012048_JR1_PB
|
|
Found STATION_JR_PB config for S012055_JR1_PB
|
|
Found STATION_JR_PB config for S012056_JR1_PB
|
|
Found STATION_JR_PB config for S012063_JR1_PB
|
|
Found STATION_JR_PB config for S012064_JR1_PB
|
|
Found STATION_JR_PB config for S012002_JR1_PB
|
|
Found STATION_JR_PB config for S012014_JR1_PB
|
|
Found STATION_JR_PB config for S012022_JR1_PB
|
|
Found STATION_JR_PB config for S012023_JR1_PB
|
|
Found STATION_JR_PB config for S012024_JR1_PB
|
|
Found STATION_JR_PB config for S012031_JR1_PB
|
|
Found STATION_JR_PB config for S012032_JR1_PB
|
|
Found STATION_JR_PB config for S013001_JR1_PB
|
|
Found STATION_JR_PB config for S013003_JR1_PB
|
|
Found STATION_JR_PB config for S013034_JR1_PB
|
|
Found STATION_JR_PB config for S013041_JR1_PB
|
|
Found STATION_JR_PB config for S013042_JR1_PB
|
|
Found STATION_JR_PB config for S013049_JR1_PB
|
|
Found STATION_JR_PB config for S013050_JR1_PB
|
|
Found STATION_JR_PB config for S013057_JR1_PB
|
|
Found STATION_JR_PB config for S013058_JR1_PB
|
|
Found STATION_JR_PB config for S013009_JR1_PB
|
|
Found STATION_JR_PB config for S013010_JR1_PB
|
|
Found STATION_JR_PB config for S013017_JR1_PB
|
|
Found STATION_JR_PB config for S013018_JR1_PB
|
|
Found STATION_JR_PB config for S013025_JR1_PB
|
|
Found STATION_JR_PB config for S013026_JR1_PB
|
|
Found STATION_JR_PB config for S013033_JR1_PB
|
|
Created SafetyTagMapping.txt with 32 mappings
|
|
File: /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/generated_projects/SAT9_MCM05/SafetyTagMapping.txt
|
|
Found STATION_JR_PB config for S012001_JR1_PB
|
|
Found STATION_JR_PB config for S012039_JR1_PB
|
|
Found STATION_JR_PB config for S012047_JR1_PB
|
|
Found STATION_JR_PB config for S012048_JR1_PB
|
|
Found STATION_JR_PB config for S012055_JR1_PB
|
|
Found STATION_JR_PB config for S012056_JR1_PB
|
|
Found STATION_JR_PB config for S012063_JR1_PB
|
|
Found STATION_JR_PB config for S012064_JR1_PB
|
|
Found STATION_JR_PB config for S012002_JR1_PB
|
|
Found STATION_JR_PB config for S012014_JR1_PB
|
|
Found STATION_JR_PB config for S012022_JR1_PB
|
|
Found STATION_JR_PB config for S012023_JR1_PB
|
|
Found STATION_JR_PB config for S012024_JR1_PB
|
|
Found STATION_JR_PB config for S012031_JR1_PB
|
|
Found STATION_JR_PB config for S012032_JR1_PB
|
|
Found STATION_JR_PB config for S013001_JR1_PB
|
|
Found STATION_JR_PB config for S013003_JR1_PB
|
|
Found STATION_JR_PB config for S013034_JR1_PB
|
|
Found STATION_JR_PB config for S013041_JR1_PB
|
|
Found STATION_JR_PB config for S013042_JR1_PB
|
|
Found STATION_JR_PB config for S013049_JR1_PB
|
|
Found STATION_JR_PB config for S013050_JR1_PB
|
|
Found STATION_JR_PB config for S013057_JR1_PB
|
|
Found STATION_JR_PB config for S013058_JR1_PB
|
|
Found STATION_JR_PB config for S013009_JR1_PB
|
|
Found STATION_JR_PB config for S013010_JR1_PB
|
|
Found STATION_JR_PB config for S013017_JR1_PB
|
|
Found STATION_JR_PB config for S013018_JR1_PB
|
|
Found STATION_JR_PB config for S013025_JR1_PB
|
|
Found STATION_JR_PB config for S013026_JR1_PB
|
|
Found STATION_JR_PB config for S013033_JR1_PB
|
|
FIOM DPM1_VS01B_FIOM1 -> DPM DPM1_VS01B
|
|
FIOM DPM1_VS01B_FIOM2 -> DPM DPM1_VS01B
|
|
FIOM DPM1_VS01B_FIOM3 -> DPM DPM1_VS01B
|
|
FIOM DPM1_VS01B_FIOM4 -> DPM DPM1_VS01B
|
|
FIOM DPM1_VS01B_FIOM5 -> DPM DPM1_VS01B
|
|
FIOM DPM1_VS01B_FIOM6 -> DPM DPM1_VS01B
|
|
FIOM DPM1_VS01B_FIOM7 -> DPM DPM1_VS01B
|
|
FIOM DPM1_VS01B_FIOM8 -> DPM DPM1_VS01B
|
|
FIOM DPM1_VS01B_FIOM9 -> DPM DPM1_VS01B
|
|
FIOM DPM1_VS01B_FIOM10 -> DPM DPM1_VS01B
|
|
FIOM DPM1_VS01B_FIOM11 -> DPM DPM1_VS01B
|
|
FIOM DPM1_VS01B_FIOM12 -> DPM DPM1_VS01B
|
|
FIOM DPM1_VS01B_FIOM13 -> DPM DPM1_VS01B
|
|
FIOM DPM1_VS01B_FIOM14 -> DPM DPM1_VS01B
|
|
FIOM DPM1_VS01B_FIOM15 -> DPM DPM1_VS01B
|
|
FIOM DPM1_VS01B_FIOM16 -> DPM DPM1_VS01B
|
|
FIOM DPM1_VS01C_FIOM1 -> DPM DPM1_VS01C
|
|
FIOM DPM1_VS01C_FIOM2 -> DPM DPM1_VS01C
|
|
FIOM DPM1_VS01C_FIOM3 -> DPM DPM1_VS01C
|
|
FIOM DPM1_VS01C_FIOM4 -> DPM DPM1_VS01C
|
|
FIOM DPM1_VS01C_FIOM5 -> DPM DPM1_VS01C
|
|
FIOM DPM1_VS01C_FIOM6 -> DPM DPM1_VS01C
|
|
FIOM DPM1_VS01C_FIOM7 -> DPM DPM1_VS01C
|
|
FIOM DPM1_VS01C_FIOM8 -> DPM DPM1_VS01C
|
|
FIOM DPM1_VS01C_FIOM9 -> DPM DPM1_VS01C
|
|
FIOM DPM1_VS01C_FIOM10 -> DPM DPM1_VS01C
|
|
FIOM DPM1_VS01C_FIOM11 -> DPM DPM1_VS01C
|
|
FIOM DPM1_VS01C_FIOM12 -> DPM DPM1_VS01C
|
|
FIOM DPM1_VS01C_FIOM13 -> DPM DPM1_VS01C
|
|
FIOM DPM1_VS01C_FIOM14 -> DPM DPM1_VS01C
|
|
FIOM DPM1_VS01C_FIOM15 -> DPM DPM1_VS01C
|
|
|
|
[R090_STATION_JR_PB] Starting STATION_JR_PB routine generation...
|
|
Found 31 STATION_JR_PB configurations
|
|
Generated 31 STATION_JR_PB rungs
|
|
|
|
[R101_FPE] Starting FPE routine generation...
|
|
Found 351 FPE configurations
|
|
Generated 351 FPE rungs
|
|
Created safety tag mapping file: /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/generated_projects/SAT9_MCM05/SafetyTagMapping.txt
|
|
|
|
=== Step 2: Routines Generator stderr ===
|
|
[20:20:27] [INFO] [logging_config.py:128:_log_with_context] Logging to file: /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/logs/workflow_SAT9_MCM05_20250904_202021.log
|
|
[20:20:27] [INFO] [logging_config.py:128:_log_with_context] === Generating All PLC Artifacts ===
|
|
[20:20:27] [INFO] [logging_config.py:128:_log_with_context] Generating SafetyProgram L5X...
|
|
[20:20:27] [WARNING] [logging_config.py:128:_log_with_context] LimitedSafetyProgramGenerator is deprecated; using ModernSafetyProgramGenerator
|
|
[20:20:27] [INFO] [logging_config.py:128:_log_with_context] Starting ModernSafetyProgramGenerator generation
|
|
[20:20:27] [DEBUG] [logging_config.py:128:_log_with_context] Creating SafetyProgram XML structure
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: main_routine (core)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: apf (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: belt_tracking (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: cb_monitor (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: d2c_chute (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: dpm (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: encoder (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: estops (safety)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: estop_check (safety)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: extendo (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: fioh (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: fiom (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: flow_ctrl (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: fpe (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: inputs (safety)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: jpe (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: mcm (core)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: outputs (safety)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: pb_chute (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: pmm (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: rack (core)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: resets (safety)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: safety_tag_map (core)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: safety_tag_mapping (safety)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: speed_ctrl (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: station_epc (safety)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: station_jr_chute (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: station_jr_pb (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: station_ss_pb (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: station_s_pb (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: taching_belts (device)
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Registered plugin: zones (safety)
|
|
[20:20:27] [INFO] [logging_config.py:128:_log_with_context] Generating safety routines...
|
|
[20:20:27] [INFO] [logging_config.py:128:_log_with_context] Plugin inputs cannot generate with current data
|
|
[20:20:27] [INFO] [logging_config.py:128:_log_with_context] Plugin outputs cannot generate with current data
|
|
[20:20:27] [INFO] [logging_config.py:128:_log_with_context] Plugin resets cannot generate with current data
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Zones: subsystem key
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Zones: heuristic best match
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Zones: using DEFAULT group
|
|
[20:20:27] [DEBUG] [logging_config.py:126:_log_with_context] Zones: loaded
|
|
[20:20:27] [DEBUG] [logging_config.py:128:_log_with_context] Generating routine: zones
|
|
[20:20:27] [DEBUG] [logging_config.py:128:_log_with_context] Available DCS controllers: {}
|
|
[20:20:27] [INFO] [logging_config.py:128:_log_with_context] Successfully generated routine: zones
|
|
[20:20:27] [INFO] [logging_config.py:128:_log_with_context] Plugin estops cannot generate with current data
|
|
[20:20:27] [INFO] [logging_config.py:128:_log_with_context] Safety routine generation results: {'inputs': False, 'outputs': False, 'resets': False, 'zones': True, 'estops': False}
|
|
[20:20:27] [DEBUG] [logging_config.py:128:_log_with_context] Added safety tag map with 1 tags
|
|
[20:20:27] [INFO] [logging_config.py:126:_log_with_context] Routines created (2): MainRoutine, R030_ZONES
|
|
[20:20:27] [INFO] [logging_config.py:126:_log_with_context] - R030_ZONES: 1 rungs | example: XIC(MCM_EPB_DCS_CTRL.O1)OTE(EStop_MCM_OK);
|
|
[20:20:27] [INFO] [logging_config.py:126:_log_with_context] - MainRoutine: 1 rungs | example: [JSR(R010_INPUTS,0) ,JSR(R011_OUTPUTS,0) ,JSR(R012_RESETS,0) ,JSR(R020_ESTOPS,0) ,JSR(R030_ZONES,0) ];
|
|
[20:20:27] [INFO] [logging_config.py:128:_log_with_context] Successfully completed ModernSafetyProgramGenerator generation
|
|
[20:20:27] [INFO] [logging_config.py:128:_log_with_context] Written ModernSafetyProgramGenerator to /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/generated_projects/SAT9_MCM05/SafetyProgram_Generated.L5X
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] [SUCCESS] SafetyProgram written to /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/generated_projects/SAT9_MCM05/SafetyProgram_Generated.L5X
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Generating MainProgram L5X...
|
|
[20:20:28] [WARNING] [logging_config.py:128:_log_with_context] LimitedMainProgramGenerator is deprecated; using ModernMainProgramGenerator
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Starting ModernMainProgramGenerator generation
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] Creating MainProgram XML structure
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] Adding controller tags...
|
|
[20:20:28] [DEBUG] [logging_config.py:126:_log_with_context] Zones: subsystem key
|
|
[20:20:28] [DEBUG] [logging_config.py:126:_log_with_context] Zones: heuristic best match
|
|
[20:20:28] [DEBUG] [logging_config.py:126:_log_with_context] Zones: using DEFAULT group
|
|
[20:20:28] [DEBUG] [logging_config.py:126:_log_with_context] Zones: loaded
|
|
[20:20:28] [DEBUG] [logging_config.py:126:_log_with_context] Extracting FPE data
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Data: FPE count=351
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012003_PE1 base=S012003_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012003_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012003_PE1: conveyor=S012003_PE1_VFD1.CTRL parent_fault=S012003_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012003_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012003_PE2 base=S012003_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012003_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012003_PE2: conveyor=S012003_PE2_VFD1.CTRL parent_fault=S012003_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012003_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012003_PE3 base=S012003_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012003_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012003_PE3: conveyor=S012003_PE3_VFD1.CTRL parent_fault=S012003_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012003_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012001_PE1 base=S012001_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012001_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012001_PE1: conveyor=S012001_PE1_VFD1.CTRL parent_fault=S012001_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012001_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012001_PE2 base=S012001_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012001_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012001_PE2: conveyor=S012001_PE2_VFD1.CTRL parent_fault=S012001_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012001_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012001_PE3 base=S012001_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012001_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012001_PE3: conveyor=S012001_PE3_VFD1.CTRL parent_fault=S012001_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012001_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012005_PE1 base=S012005_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012005_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012005_PE1: conveyor=S012005_PE1_VFD1.CTRL parent_fault=S012005_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012005_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012005_PE2 base=S012005_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012005_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012005_PE2: conveyor=S012005_PE2_VFD1.CTRL parent_fault=S012005_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012005_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012005_PE3 base=S012005_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012005_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012005_PE3: conveyor=S012005_PE3_VFD1.CTRL parent_fault=S012005_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012005_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012007_PE1 base=S012007_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012007_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012007_PE1: conveyor=S012007_PE1_VFD1.CTRL parent_fault=S012007_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012007_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012007_PE2 base=S012007_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012007_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012007_PE2: conveyor=S012007_PE2_VFD1.CTRL parent_fault=S012007_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012007_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012007_PE3 base=S012007_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012007_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012007_PE3: conveyor=S012007_PE3_VFD1.CTRL parent_fault=S012007_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH1:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012007_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012041_PE1 base=S012041_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012041_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012041_PE1: conveyor=S012041_PE1_VFD1.CTRL parent_fault=S012041_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012041_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012041_PE2 base=S012041_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012041_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012041_PE2: conveyor=S012041_PE2_VFD1.CTRL parent_fault=S012041_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012041_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012041_PE3 base=S012041_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012041_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012041_PE3: conveyor=S012041_PE3_VFD1.CTRL parent_fault=S012041_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012041_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012039_PE1 base=S012039_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012039_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012039_PE1: conveyor=S012039_PE1_VFD1.CTRL parent_fault=S012039_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012039_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012039_PE2 base=S012039_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012039_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012039_PE2: conveyor=S012039_PE2_VFD1.CTRL parent_fault=S012039_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012039_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012039_PE3 base=S012039_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012039_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012039_PE3: conveyor=S012039_PE3_VFD1.CTRL parent_fault=S012039_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012039_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012043_PE1 base=S012043_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012043_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012043_PE1: conveyor=S012043_PE1_VFD1.CTRL parent_fault=S012043_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012043_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012043_PE2 base=S012043_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012043_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012043_PE2: conveyor=S012043_PE2_VFD1.CTRL parent_fault=S012043_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012043_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012043_PE3 base=S012043_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012043_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012043_PE3: conveyor=S012043_PE3_VFD1.CTRL parent_fault=S012043_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012043_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012045_PE1 base=S012045_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012045_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012045_PE1: conveyor=S012045_PE1_VFD1.CTRL parent_fault=S012045_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012045_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012045_PE2 base=S012045_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012045_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012045_PE2: conveyor=S012045_PE2_VFD1.CTRL parent_fault=S012045_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012045_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012045_PE3 base=S012045_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012045_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012045_PE3: conveyor=S012045_PE3_VFD1.CTRL parent_fault=S012045_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH10:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012045_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012044_PE1 base=S012044_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012044_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012044_PE1: conveyor=S012044_PE1_VFD1.CTRL parent_fault=S012044_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012044_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012044_PE2 base=S012044_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012044_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012044_PE2: conveyor=S012044_PE2_VFD1.CTRL parent_fault=S012044_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012044_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012044_PE3 base=S012044_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012044_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012044_PE3: conveyor=S012044_PE3_VFD1.CTRL parent_fault=S012044_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012044_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012046_PE1 base=S012046_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012046_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012046_PE1: conveyor=S012046_PE1_VFD1.CTRL parent_fault=S012046_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012046_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012046_PE2 base=S012046_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012046_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012046_PE2: conveyor=S012046_PE2_VFD1.CTRL parent_fault=S012046_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012046_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012046_PE3 base=S012046_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012046_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012046_PE3: conveyor=S012046_PE3_VFD1.CTRL parent_fault=S012046_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012046_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012042_PE1 base=S012042_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012042_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012042_PE1: conveyor=S012042_PE1_VFD1.CTRL parent_fault=S012042_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012042_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012042_PE2 base=S012042_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012042_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012042_PE2: conveyor=S012042_PE2_VFD1.CTRL parent_fault=S012042_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012042_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012042_PE3 base=S012042_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012042_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012042_PE3: conveyor=S012042_PE3_VFD1.CTRL parent_fault=S012042_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH11:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012042_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012049_PE1 base=S012049_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012049_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012049_PE1: conveyor=S012049_PE1_VFD1.CTRL parent_fault=S012049_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012049_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012049_PE2 base=S012049_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012049_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012049_PE2: conveyor=S012049_PE2_VFD1.CTRL parent_fault=S012049_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012049_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012049_PE3 base=S012049_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012049_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012049_PE3: conveyor=S012049_PE3_VFD1.CTRL parent_fault=S012049_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012049_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012047_PE1 base=S012047_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012047_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012047_PE1: conveyor=S012047_PE1_VFD1.CTRL parent_fault=S012047_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012047_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012047_PE2 base=S012047_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012047_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012047_PE2: conveyor=S012047_PE2_VFD1.CTRL parent_fault=S012047_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012047_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012047_PE3 base=S012047_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012047_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012047_PE3: conveyor=S012047_PE3_VFD1.CTRL parent_fault=S012047_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012047_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012051_PE1 base=S012051_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012051_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012051_PE1: conveyor=S012051_PE1_VFD1.CTRL parent_fault=S012051_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012051_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012051_PE2 base=S012051_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012051_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012051_PE2: conveyor=S012051_PE2_VFD1.CTRL parent_fault=S012051_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012051_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012051_PE3 base=S012051_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012051_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012051_PE3: conveyor=S012051_PE3_VFD1.CTRL parent_fault=S012051_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012051_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012053_PE1 base=S012053_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012053_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012053_PE1: conveyor=S012053_PE1_VFD1.CTRL parent_fault=S012053_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012053_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012053_PE2 base=S012053_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012053_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012053_PE2: conveyor=S012053_PE2_VFD1.CTRL parent_fault=S012053_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012053_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012053_PE3 base=S012053_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012053_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012053_PE3: conveyor=S012053_PE3_VFD1.CTRL parent_fault=S012053_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH12:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012053_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012052_PE1 base=S012052_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012052_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012052_PE1: conveyor=S012052_PE1_VFD1.CTRL parent_fault=S012052_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012052_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012052_PE2 base=S012052_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012052_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012052_PE2: conveyor=S012052_PE2_VFD1.CTRL parent_fault=S012052_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012052_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012052_PE3 base=S012052_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012052_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012052_PE3: conveyor=S012052_PE3_VFD1.CTRL parent_fault=S012052_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012052_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012050_PE1 base=S012050_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012050_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012050_PE1: conveyor=S012050_PE1_VFD1.CTRL parent_fault=S012050_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012050_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012050_PE2 base=S012050_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012050_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012050_PE2: conveyor=S012050_PE2_VFD1.CTRL parent_fault=S012050_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012050_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012050_PE3 base=S012050_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012050_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012050_PE3: conveyor=S012050_PE3_VFD1.CTRL parent_fault=S012050_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012050_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012048_PE1 base=S012048_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012048_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012048_PE1: conveyor=S012048_PE1_VFD1.CTRL parent_fault=S012048_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012048_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012048_PE2 base=S012048_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012048_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012048_PE2: conveyor=S012048_PE2_VFD1.CTRL parent_fault=S012048_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012048_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012048_PE3 base=S012048_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012048_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012048_PE3: conveyor=S012048_PE3_VFD1.CTRL parent_fault=S012048_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH13:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012048_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012057_PE1 base=S012057_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012057_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012057_PE1: conveyor=S012057_PE1_VFD1.CTRL parent_fault=S012057_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012057_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012057_PE2 base=S012057_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012057_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012057_PE2: conveyor=S012057_PE2_VFD1.CTRL parent_fault=S012057_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012057_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012057_PE3 base=S012057_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012057_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012057_PE3: conveyor=S012057_PE3_VFD1.CTRL parent_fault=S012057_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012057_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012055_PE1 base=S012055_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012055_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012055_PE1: conveyor=S012055_PE1_VFD1.CTRL parent_fault=S012055_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012055_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012055_PE2 base=S012055_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012055_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012055_PE2: conveyor=S012055_PE2_VFD1.CTRL parent_fault=S012055_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012055_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012055_PE3 base=S012055_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012055_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012055_PE3: conveyor=S012055_PE3_VFD1.CTRL parent_fault=S012055_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012055_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012059_PE1 base=S012059_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012059_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012059_PE1: conveyor=S012059_PE1_VFD1.CTRL parent_fault=S012059_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012059_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012059_PE2 base=S012059_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012059_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012059_PE2: conveyor=S012059_PE2_VFD1.CTRL parent_fault=S012059_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012059_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012059_PE3 base=S012059_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012059_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012059_PE3: conveyor=S012059_PE3_VFD1.CTRL parent_fault=S012059_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012059_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012061_PE1 base=S012061_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012061_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012061_PE1: conveyor=S012061_PE1_VFD1.CTRL parent_fault=S012061_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012061_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012061_PE2 base=S012061_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012061_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012061_PE2: conveyor=S012061_PE2_VFD1.CTRL parent_fault=S012061_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012061_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012061_PE3 base=S012061_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012061_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012061_PE3: conveyor=S012061_PE3_VFD1.CTRL parent_fault=S012061_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH14:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012061_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012060_PE1 base=S012060_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012060_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012060_PE1: conveyor=S012060_PE1_VFD1.CTRL parent_fault=S012060_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012060_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012060_PE2 base=S012060_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012060_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012060_PE2: conveyor=S012060_PE2_VFD1.CTRL parent_fault=S012060_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012060_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012060_PE3 base=S012060_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012060_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012060_PE3: conveyor=S012060_PE3_VFD1.CTRL parent_fault=S012060_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012060_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012062_PE1 base=S012062_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012062_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012062_PE1: conveyor=S012062_PE1_VFD1.CTRL parent_fault=S012062_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012062_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012062_PE2 base=S012062_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012062_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012062_PE2: conveyor=S012062_PE2_VFD1.CTRL parent_fault=S012062_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012062_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012062_PE3 base=S012062_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012062_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012062_PE3: conveyor=S012062_PE3_VFD1.CTRL parent_fault=S012062_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012062_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012058_PE1 base=S012058_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012058_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012058_PE1: conveyor=S012058_PE1_VFD1.CTRL parent_fault=S012058_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012058_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012058_PE2 base=S012058_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012058_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012058_PE2: conveyor=S012058_PE2_VFD1.CTRL parent_fault=S012058_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012058_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012058_PE3 base=S012058_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012058_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012058_PE3: conveyor=S012058_PE3_VFD1.CTRL parent_fault=S012058_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012058_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012056_PE1 base=S012056_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012056_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012056_PE1: conveyor=S012056_PE1_VFD1.CTRL parent_fault=S012056_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012056_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012056_PE2 base=S012056_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012056_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012056_PE2: conveyor=S012056_PE2_VFD1.CTRL parent_fault=S012056_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012056_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012056_PE3 base=S012056_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012056_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012056_PE3: conveyor=S012056_PE3_VFD1.CTRL parent_fault=S012056_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH15:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012056_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012065_PE1 base=S012065_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012065_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012065_PE1: conveyor=S012065_PE1_VFD1.CTRL parent_fault=S012065_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012065_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012065_PE2 base=S012065_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012065_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012065_PE2: conveyor=S012065_PE2_VFD1.CTRL parent_fault=S012065_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012065_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012065_PE3 base=S012065_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012065_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012065_PE3: conveyor=S012065_PE3_VFD1.CTRL parent_fault=S012065_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012065_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012063_PE1 base=S012063_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012063_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012063_PE1: conveyor=S012063_PE1_VFD1.CTRL parent_fault=S012063_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012063_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012063_PE2 base=S012063_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012063_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012063_PE2: conveyor=S012063_PE2_VFD1.CTRL parent_fault=S012063_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012063_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012063_PE3 base=S012063_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012063_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012063_PE3: conveyor=S012063_PE3_VFD1.CTRL parent_fault=S012063_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012063_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012067_PE1 base=S012067_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012067_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012067_PE1: conveyor=S012067_PE1_VFD1.CTRL parent_fault=S012067_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012067_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012067_PE2 base=S012067_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012067_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012067_PE2: conveyor=S012067_PE2_VFD1.CTRL parent_fault=S012067_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012067_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012067_PE3 base=S012067_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012067_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012067_PE3: conveyor=S012067_PE3_VFD1.CTRL parent_fault=S012067_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012067_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012069_PE1 base=S012069_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012069_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012069_PE1: conveyor=S012069_PE1_VFD1.CTRL parent_fault=S012069_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012069_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012069_PE2 base=S012069_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012069_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012069_PE2: conveyor=S012069_PE2_VFD1.CTRL parent_fault=S012069_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012069_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012069_PE3 base=S012069_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012069_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012069_PE3: conveyor=S012069_PE3_VFD1.CTRL parent_fault=S012069_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH16:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012069_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012068_PE1 base=S012068_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012068_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012068_PE1: conveyor=S012068_PE1_VFD1.CTRL parent_fault=S012068_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012068_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012068_PE2 base=S012068_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012068_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012068_PE2: conveyor=S012068_PE2_VFD1.CTRL parent_fault=S012068_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012068_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012068_PE3 base=S012068_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012068_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012068_PE3: conveyor=S012068_PE3_VFD1.CTRL parent_fault=S012068_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012068_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012066_PE1 base=S012066_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012066_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012066_PE1: conveyor=S012066_PE1_VFD1.CTRL parent_fault=S012066_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012066_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012066_PE2 base=S012066_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012066_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012066_PE2: conveyor=S012066_PE2_VFD1.CTRL parent_fault=S012066_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012066_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012066_PE3 base=S012066_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012066_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012066_PE3: conveyor=S012066_PE3_VFD1.CTRL parent_fault=S012066_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012066_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012064_PE1 base=S012064_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012064_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012064_PE1: conveyor=S012064_PE1_VFD1.CTRL parent_fault=S012064_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012064_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012064_PE2 base=S012064_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012064_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012064_PE2: conveyor=S012064_PE2_VFD1.CTRL parent_fault=S012064_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012064_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012064_PE3 base=S012064_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012064_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012064_PE3: conveyor=S012064_PE3_VFD1.CTRL parent_fault=S012064_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH17:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012064_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012006_PE1 base=S012006_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012006_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012006_PE1: conveyor=S012006_PE1_VFD1.CTRL parent_fault=S012006_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012006_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012006_PE2 base=S012006_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012006_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012006_PE2: conveyor=S012006_PE2_VFD1.CTRL parent_fault=S012006_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012006_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012006_PE3 base=S012006_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012006_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012006_PE3: conveyor=S012006_PE3_VFD1.CTRL parent_fault=S012006_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012006_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012008_PE1 base=S012008_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012008_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012008_PE1: conveyor=S012008_PE1_VFD1.CTRL parent_fault=S012008_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012008_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012008_PE2 base=S012008_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012008_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012008_PE2: conveyor=S012008_PE2_VFD1.CTRL parent_fault=S012008_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012008_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012008_PE3 base=S012008_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012008_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012008_PE3: conveyor=S012008_PE3_VFD1.CTRL parent_fault=S012008_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012008_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012004_PE1 base=S012004_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012004_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012004_PE1: conveyor=S012004_PE1_VFD1.CTRL parent_fault=S012004_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012004_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012004_PE2 base=S012004_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012004_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012004_PE2: conveyor=S012004_PE2_VFD1.CTRL parent_fault=S012004_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012004_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012004_PE3 base=S012004_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012004_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012004_PE3: conveyor=S012004_PE3_VFD1.CTRL parent_fault=S012004_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012004_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012002_PE1 base=S012002_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012002_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012002_PE1: conveyor=S012002_PE1_VFD1.CTRL parent_fault=S012002_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012002_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012002_PE2 base=S012002_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012002_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012002_PE2: conveyor=S012002_PE2_VFD1.CTRL parent_fault=S012002_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012002_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012002_PE3 base=S012002_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012002_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012002_PE3: conveyor=S012002_PE3_VFD1.CTRL parent_fault=S012002_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH2:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012002_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012018_PE1 base=S012018_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012018_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012018_PE1: conveyor=S012018_PE1_VFD1.CTRL parent_fault=S012018_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012018_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012018_PE2 base=S012018_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012018_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012018_PE2: conveyor=S012018_PE2_VFD1.CTRL parent_fault=S012018_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012018_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012018_PE3 base=S012018_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012018_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012018_PE3: conveyor=S012018_PE3_VFD1.CTRL parent_fault=S012018_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012018_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012020_PE1 base=S012020_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012020_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012020_PE1: conveyor=S012020_PE1_VFD1.CTRL parent_fault=S012020_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012020_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012020_PE2 base=S012020_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012020_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012020_PE2: conveyor=S012020_PE2_VFD1.CTRL parent_fault=S012020_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012020_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012020_PE3 base=S012020_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012020_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012020_PE3: conveyor=S012020_PE3_VFD1.CTRL parent_fault=S012020_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012020_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012016_PE1 base=S012016_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012016_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012016_PE1: conveyor=S012016_PE1_VFD1.CTRL parent_fault=S012016_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012016_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012016_PE2 base=S012016_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012016_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012016_PE2: conveyor=S012016_PE2_VFD1.CTRL parent_fault=S012016_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012016_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012016_PE3 base=S012016_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012016_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012016_PE3: conveyor=S012016_PE3_VFD1.CTRL parent_fault=S012016_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012016_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012014_PE1 base=S012014_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012014_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012014_PE1: conveyor=S012014_PE1_VFD1.CTRL parent_fault=S012014_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012014_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012014_PE2 base=S012014_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012014_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012014_PE2: conveyor=S012014_PE2_VFD1.CTRL parent_fault=S012014_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012014_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012014_PE3 base=S012014_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012014_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012014_PE3: conveyor=S012014_PE3_VFD1.CTRL parent_fault=S012014_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH3:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012014_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012022_PE1 base=S012022_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012022_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012022_PE1: conveyor=S012022_PE1_VFD1.CTRL parent_fault=S012022_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH4:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012022_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012022_PE2 base=S012022_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012022_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012022_PE2: conveyor=S012022_PE2_VFD1.CTRL parent_fault=S012022_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH4:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012022_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012022_PE3 base=S012022_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012022_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012022_PE3: conveyor=S012022_PE3_VFD1.CTRL parent_fault=S012022_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH4:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012022_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012025_PE1 base=S012025_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012025_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012025_PE1: conveyor=S012025_PE1_VFD1.CTRL parent_fault=S012025_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012025_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012025_PE2 base=S012025_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012025_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012025_PE2: conveyor=S012025_PE2_VFD1.CTRL parent_fault=S012025_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012025_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012025_PE3 base=S012025_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012025_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012025_PE3: conveyor=S012025_PE3_VFD1.CTRL parent_fault=S012025_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012025_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012023_PE1 base=S012023_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012023_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012023_PE1: conveyor=S012023_PE1_VFD1.CTRL parent_fault=S012023_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012023_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012023_PE2 base=S012023_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012023_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012023_PE2: conveyor=S012023_PE2_VFD1.CTRL parent_fault=S012023_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012023_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012023_PE3 base=S012023_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012023_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012023_PE3: conveyor=S012023_PE3_VFD1.CTRL parent_fault=S012023_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012023_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012027_PE1 base=S012027_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012027_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012027_PE1: conveyor=S012027_PE1_VFD1.CTRL parent_fault=S012027_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012027_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012027_PE2 base=S012027_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012027_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012027_PE2: conveyor=S012027_PE2_VFD1.CTRL parent_fault=S012027_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012027_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012027_PE3 base=S012027_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012027_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012027_PE3: conveyor=S012027_PE3_VFD1.CTRL parent_fault=S012027_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012027_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012029_PE1 base=S012029_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012029_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012029_PE1: conveyor=S012029_PE1_VFD1.CTRL parent_fault=S012029_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012029_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012029_PE2 base=S012029_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012029_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012029_PE2: conveyor=S012029_PE2_VFD1.CTRL parent_fault=S012029_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012029_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012029_PE3 base=S012029_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012029_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012029_PE3: conveyor=S012029_PE3_VFD1.CTRL parent_fault=S012029_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH5:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012029_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012028_PE1 base=S012028_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012028_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012028_PE1: conveyor=S012028_PE1_VFD1.CTRL parent_fault=S012028_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012028_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012028_PE2 base=S012028_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012028_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012028_PE2: conveyor=S012028_PE2_VFD1.CTRL parent_fault=S012028_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012028_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012028_PE3 base=S012028_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012028_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012028_PE3: conveyor=S012028_PE3_VFD1.CTRL parent_fault=S012028_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012028_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012030_PE1 base=S012030_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012030_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012030_PE1: conveyor=S012030_PE1_VFD1.CTRL parent_fault=S012030_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012030_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012030_PE2 base=S012030_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012030_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012030_PE2: conveyor=S012030_PE2_VFD1.CTRL parent_fault=S012030_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012030_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012030_PE3 base=S012030_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012030_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012030_PE3: conveyor=S012030_PE3_VFD1.CTRL parent_fault=S012030_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012030_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012026_PE1 base=S012026_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012026_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012026_PE1: conveyor=S012026_PE1_VFD1.CTRL parent_fault=S012026_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012026_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012026_PE2 base=S012026_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012026_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012026_PE2: conveyor=S012026_PE2_VFD1.CTRL parent_fault=S012026_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012026_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012026_PE3 base=S012026_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012026_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012026_PE3: conveyor=S012026_PE3_VFD1.CTRL parent_fault=S012026_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012026_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012024_PE1 base=S012024_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012024_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012024_PE1: conveyor=S012024_PE1_VFD1.CTRL parent_fault=S012024_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012024_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012024_PE2 base=S012024_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012024_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012024_PE2: conveyor=S012024_PE2_VFD1.CTRL parent_fault=S012024_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012024_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012024_PE3 base=S012024_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012024_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012024_PE3: conveyor=S012024_PE3_VFD1.CTRL parent_fault=S012024_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH6:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012024_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012033_PE1 base=S012033_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012033_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012033_PE1: conveyor=S012033_PE1_VFD1.CTRL parent_fault=S012033_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012033_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012033_PE2 base=S012033_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012033_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012033_PE2: conveyor=S012033_PE2_VFD1.CTRL parent_fault=S012033_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012033_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012033_PE3 base=S012033_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012033_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012033_PE3: conveyor=S012033_PE3_VFD1.CTRL parent_fault=S012033_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012033_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012031_PE1 base=S012031_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012031_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012031_PE1: conveyor=S012031_PE1_VFD1.CTRL parent_fault=S012031_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012031_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012031_PE2 base=S012031_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012031_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012031_PE2: conveyor=S012031_PE2_VFD1.CTRL parent_fault=S012031_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012031_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012031_PE3 base=S012031_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012031_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012031_PE3: conveyor=S012031_PE3_VFD1.CTRL parent_fault=S012031_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012031_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012035_PE1 base=S012035_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012035_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012035_PE1: conveyor=S012035_PE1_VFD1.CTRL parent_fault=S012035_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012035_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012035_PE2 base=S012035_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012035_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012035_PE2: conveyor=S012035_PE2_VFD1.CTRL parent_fault=S012035_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012035_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012035_PE3 base=S012035_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012035_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012035_PE3: conveyor=S012035_PE3_VFD1.CTRL parent_fault=S012035_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012035_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012037_PE1 base=S012037_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012037_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012037_PE1: conveyor=S012037_PE1_VFD1.CTRL parent_fault=S012037_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012037_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012037_PE2 base=S012037_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012037_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012037_PE2: conveyor=S012037_PE2_VFD1.CTRL parent_fault=S012037_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012037_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012037_PE3 base=S012037_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012037_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012037_PE3: conveyor=S012037_PE3_VFD1.CTRL parent_fault=S012037_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH7:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012037_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012036_PE1 base=S012036_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012036_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012036_PE1: conveyor=S012036_PE1_VFD1.CTRL parent_fault=S012036_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S012036_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012036_PE2 base=S012036_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012036_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012036_PE2: conveyor=S012036_PE2_VFD1.CTRL parent_fault=S012036_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S012036_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012036_PE3 base=S012036_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012036_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012036_PE3: conveyor=S012036_PE3_VFD1.CTRL parent_fault=S012036_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S012036_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012038_PE1 base=S012038_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012038_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012038_PE1: conveyor=S012038_PE1_VFD1.CTRL parent_fault=S012038_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S012038_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012038_PE2 base=S012038_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012038_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012038_PE2: conveyor=S012038_PE2_VFD1.CTRL parent_fault=S012038_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S012038_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012038_PE3 base=S012038_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012038_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012038_PE3: conveyor=S012038_PE3_VFD1.CTRL parent_fault=S012038_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S012038_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012034_PE1 base=S012034_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012034_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012034_PE1: conveyor=S012034_PE1_VFD1.CTRL parent_fault=S012034_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S012034_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012034_PE2 base=S012034_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012034_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012034_PE2: conveyor=S012034_PE2_VFD1.CTRL parent_fault=S012034_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S012034_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012034_PE3 base=S012034_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012034_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012034_PE3: conveyor=S012034_PE3_VFD1.CTRL parent_fault=S012034_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S012034_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012032_PE1 base=S012032_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012032_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012032_PE1: conveyor=S012032_PE1_VFD1.CTRL parent_fault=S012032_PE1_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S012032_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012032_PE2 base=S012032_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012032_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012032_PE2: conveyor=S012032_PE2_VFD1.CTRL parent_fault=S012032_PE2_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S012032_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S012032_PE3 base=S012032_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S012032_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S012032_PE3: conveyor=S012032_PE3_VFD1.CTRL parent_fault=S012032_PE3_VFD1:I.ConnectionFaulted input=VS01B_FIOH8:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S012032_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013003_PE1 base=S013003_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013003_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013003_PE1: conveyor=S013003_PE1_VFD1.CTRL parent_fault=S013003_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013003_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013003_PE2 base=S013003_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013003_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013003_PE2: conveyor=S013003_PE2_VFD1.CTRL parent_fault=S013003_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013003_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013003_PE3 base=S013003_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013003_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013003_PE3: conveyor=S013003_PE3_VFD1.CTRL parent_fault=S013003_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013003_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013001_PE1 base=S013001_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013001_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013001_PE1: conveyor=S013001_PE1_VFD1.CTRL parent_fault=S013001_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013001_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013001_PE2 base=S013001_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013001_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013001_PE2: conveyor=S013001_PE2_VFD1.CTRL parent_fault=S013001_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013001_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013001_PE3 base=S013001_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013001_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013001_PE3: conveyor=S013001_PE3_VFD1.CTRL parent_fault=S013001_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013001_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013005_PE1 base=S013005_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013005_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013005_PE1: conveyor=S013005_PE1_VFD1.CTRL parent_fault=S013005_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013005_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013005_PE2 base=S013005_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013005_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013005_PE2: conveyor=S013005_PE2_VFD1.CTRL parent_fault=S013005_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013005_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013005_PE3 base=S013005_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013005_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013005_PE3: conveyor=S013005_PE3_VFD1.CTRL parent_fault=S013005_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013005_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013007_PE1 base=S013007_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013007_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013007_PE1: conveyor=S013007_PE1_VFD1.CTRL parent_fault=S013007_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013007_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013007_PE2 base=S013007_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013007_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013007_PE2: conveyor=S013007_PE2_VFD1.CTRL parent_fault=S013007_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013007_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013007_PE3 base=S013007_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013007_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013007_PE3: conveyor=S013007_PE3_VFD1.CTRL parent_fault=S013007_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH1:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013007_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013038_PE1 base=S013038_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013038_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013038_PE1: conveyor=S013038_PE1_VFD1.CTRL parent_fault=S013038_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013038_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013038_PE2 base=S013038_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013038_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013038_PE2: conveyor=S013038_PE2_VFD1.CTRL parent_fault=S013038_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013038_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013038_PE3 base=S013038_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013038_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013038_PE3: conveyor=S013038_PE3_VFD1.CTRL parent_fault=S013038_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013038_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013040_PE1 base=S013040_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013040_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013040_PE1: conveyor=S013040_PE1_VFD1.CTRL parent_fault=S013040_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013040_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013040_PE2 base=S013040_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013040_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013040_PE2: conveyor=S013040_PE2_VFD1.CTRL parent_fault=S013040_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013040_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013040_PE3 base=S013040_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013040_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013040_PE3: conveyor=S013040_PE3_VFD1.CTRL parent_fault=S013040_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013040_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013036_PE1 base=S013036_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013036_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013036_PE1: conveyor=S013036_PE1_VFD1.CTRL parent_fault=S013036_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013036_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013036_PE2 base=S013036_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013036_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013036_PE2: conveyor=S013036_PE2_VFD1.CTRL parent_fault=S013036_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013036_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013036_PE3 base=S013036_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013036_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013036_PE3: conveyor=S013036_PE3_VFD1.CTRL parent_fault=S013036_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013036_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013034_PE1 base=S013034_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013034_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013034_PE1: conveyor=S013034_PE1_VFD1.CTRL parent_fault=S013034_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013034_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013034_PE2 base=S013034_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013034_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013034_PE2: conveyor=S013034_PE2_VFD1.CTRL parent_fault=S013034_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013034_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013034_PE3 base=S013034_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013034_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013034_PE3: conveyor=S013034_PE3_VFD1.CTRL parent_fault=S013034_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH10:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013034_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013043_PE1 base=S013043_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013043_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013043_PE1: conveyor=S013043_PE1_VFD1.CTRL parent_fault=S013043_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013043_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013043_PE2 base=S013043_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013043_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013043_PE2: conveyor=S013043_PE2_VFD1.CTRL parent_fault=S013043_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013043_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013043_PE3 base=S013043_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013043_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013043_PE3: conveyor=S013043_PE3_VFD1.CTRL parent_fault=S013043_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013043_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013041_PE1 base=S013041_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013041_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013041_PE1: conveyor=S013041_PE1_VFD1.CTRL parent_fault=S013041_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013041_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013041_PE2 base=S013041_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013041_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013041_PE2: conveyor=S013041_PE2_VFD1.CTRL parent_fault=S013041_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013041_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013041_PE3 base=S013041_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013041_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013041_PE3: conveyor=S013041_PE3_VFD1.CTRL parent_fault=S013041_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013041_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013045_PE1 base=S013045_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013045_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013045_PE1: conveyor=S013045_PE1_VFD1.CTRL parent_fault=S013045_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013045_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013045_PE2 base=S013045_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013045_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013045_PE2: conveyor=S013045_PE2_VFD1.CTRL parent_fault=S013045_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013045_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013045_PE3 base=S013045_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013045_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013045_PE3: conveyor=S013045_PE3_VFD1.CTRL parent_fault=S013045_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013045_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013047_PE1 base=S013047_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013047_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013047_PE1: conveyor=S013047_PE1_VFD1.CTRL parent_fault=S013047_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013047_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013047_PE2 base=S013047_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013047_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013047_PE2: conveyor=S013047_PE2_VFD1.CTRL parent_fault=S013047_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013047_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013047_PE3 base=S013047_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013047_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013047_PE3: conveyor=S013047_PE3_VFD1.CTRL parent_fault=S013047_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH11:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013047_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013048_PE1 base=S013048_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013048_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013048_PE1: conveyor=S013048_PE1_VFD1.CTRL parent_fault=S013048_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013048_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013048_PE2 base=S013048_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013048_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013048_PE2: conveyor=S013048_PE2_VFD1.CTRL parent_fault=S013048_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013048_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013048_PE3 base=S013048_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013048_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013048_PE3: conveyor=S013048_PE3_VFD1.CTRL parent_fault=S013048_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013048_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013044_PE1 base=S013044_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013044_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013044_PE1: conveyor=S013044_PE1_VFD1.CTRL parent_fault=S013044_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013044_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013044_PE2 base=S013044_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013044_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013044_PE2: conveyor=S013044_PE2_VFD1.CTRL parent_fault=S013044_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013044_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013044_PE3 base=S013044_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013044_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013044_PE3: conveyor=S013044_PE3_VFD1.CTRL parent_fault=S013044_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013044_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013042_PE1 base=S013042_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013042_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013042_PE1: conveyor=S013042_PE1_VFD1.CTRL parent_fault=S013042_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013042_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013042_PE2 base=S013042_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013042_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013042_PE2: conveyor=S013042_PE2_VFD1.CTRL parent_fault=S013042_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013042_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013042_PE3 base=S013042_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013042_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013042_PE3: conveyor=S013042_PE3_VFD1.CTRL parent_fault=S013042_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH12:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013042_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013051_PE1 base=S013051_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013051_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013051_PE1: conveyor=S013051_PE1_VFD1.CTRL parent_fault=S013051_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013051_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013051_PE2 base=S013051_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013051_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013051_PE2: conveyor=S013051_PE2_VFD1.CTRL parent_fault=S013051_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013051_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013051_PE3 base=S013051_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013051_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013051_PE3: conveyor=S013051_PE3_VFD1.CTRL parent_fault=S013051_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013051_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013049_PE1 base=S013049_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013049_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013049_PE1: conveyor=S013049_PE1_VFD1.CTRL parent_fault=S013049_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013049_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013049_PE2 base=S013049_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013049_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013049_PE2: conveyor=S013049_PE2_VFD1.CTRL parent_fault=S013049_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013049_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013049_PE3 base=S013049_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013049_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013049_PE3: conveyor=S013049_PE3_VFD1.CTRL parent_fault=S013049_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013049_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013053_PE1 base=S013053_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013053_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013053_PE1: conveyor=S013053_PE1_VFD1.CTRL parent_fault=S013053_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013053_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013053_PE2 base=S013053_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013053_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013053_PE2: conveyor=S013053_PE2_VFD1.CTRL parent_fault=S013053_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013053_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013053_PE3 base=S013053_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013053_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013053_PE3: conveyor=S013053_PE3_VFD1.CTRL parent_fault=S013053_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013053_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013055_PE1 base=S013055_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013055_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013055_PE1: conveyor=S013055_PE1_VFD1.CTRL parent_fault=S013055_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013055_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013055_PE2 base=S013055_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013055_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013055_PE2: conveyor=S013055_PE2_VFD1.CTRL parent_fault=S013055_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013055_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013055_PE3 base=S013055_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013055_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013055_PE3: conveyor=S013055_PE3_VFD1.CTRL parent_fault=S013055_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH13:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013055_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013054_PE1 base=S013054_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013054_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013054_PE1: conveyor=S013054_PE1_VFD1.CTRL parent_fault=S013054_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013054_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013054_PE2 base=S013054_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013054_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013054_PE2: conveyor=S013054_PE2_VFD1.CTRL parent_fault=S013054_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013054_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013054_PE3 base=S013054_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013054_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013054_PE3: conveyor=S013054_PE3_VFD1.CTRL parent_fault=S013054_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013054_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013056_PE1 base=S013056_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013056_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013056_PE1: conveyor=S013056_PE1_VFD1.CTRL parent_fault=S013056_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013056_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013056_PE2 base=S013056_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013056_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013056_PE2: conveyor=S013056_PE2_VFD1.CTRL parent_fault=S013056_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013056_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013056_PE3 base=S013056_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013056_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013056_PE3: conveyor=S013056_PE3_VFD1.CTRL parent_fault=S013056_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013056_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013052_PE1 base=S013052_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013052_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013052_PE1: conveyor=S013052_PE1_VFD1.CTRL parent_fault=S013052_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013052_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013052_PE2 base=S013052_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013052_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013052_PE2: conveyor=S013052_PE2_VFD1.CTRL parent_fault=S013052_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013052_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013052_PE3 base=S013052_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013052_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013052_PE3: conveyor=S013052_PE3_VFD1.CTRL parent_fault=S013052_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013052_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013050_PE1 base=S013050_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013050_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013050_PE1: conveyor=S013050_PE1_VFD1.CTRL parent_fault=S013050_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013050_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013050_PE2 base=S013050_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013050_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013050_PE2: conveyor=S013050_PE2_VFD1.CTRL parent_fault=S013050_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013050_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013050_PE3 base=S013050_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013050_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013050_PE3: conveyor=S013050_PE3_VFD1.CTRL parent_fault=S013050_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH14:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013050_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013059_PE1 base=S013059_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013059_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013059_PE1: conveyor=S013059_PE1_VFD1.CTRL parent_fault=S013059_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013059_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013059_PE2 base=S013059_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013059_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013059_PE2: conveyor=S013059_PE2_VFD1.CTRL parent_fault=S013059_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013059_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013059_PE3 base=S013059_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013059_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013059_PE3: conveyor=S013059_PE3_VFD1.CTRL parent_fault=S013059_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013059_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013057_PE1 base=S013057_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013057_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013057_PE1: conveyor=S013057_PE1_VFD1.CTRL parent_fault=S013057_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013057_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013057_PE2 base=S013057_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013057_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013057_PE2: conveyor=S013057_PE2_VFD1.CTRL parent_fault=S013057_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013057_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013057_PE3 base=S013057_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013057_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013057_PE3: conveyor=S013057_PE3_VFD1.CTRL parent_fault=S013057_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013057_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013061_PE1 base=S013061_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013061_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013061_PE1: conveyor=S013061_PE1_VFD1.CTRL parent_fault=S013061_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013061_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013061_PE2 base=S013061_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013061_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013061_PE2: conveyor=S013061_PE2_VFD1.CTRL parent_fault=S013061_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013061_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013061_PE3 base=S013061_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013061_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013061_PE3: conveyor=S013061_PE3_VFD1.CTRL parent_fault=S013061_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013061_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013063_PE1 base=S013063_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013063_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013063_PE1: conveyor=S013063_PE1_VFD1.CTRL parent_fault=S013063_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013063_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013063_PE2 base=S013063_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013063_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013063_PE2: conveyor=S013063_PE2_VFD1.CTRL parent_fault=S013063_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013063_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013063_PE3 base=S013063_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013063_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013063_PE3: conveyor=S013063_PE3_VFD1.CTRL parent_fault=S013063_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH15:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013063_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013062_PE1 base=S013062_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013062_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013062_PE1: conveyor=S013062_PE1_VFD1.CTRL parent_fault=S013062_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013062_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013062_PE2 base=S013062_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013062_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013062_PE2: conveyor=S013062_PE2_VFD1.CTRL parent_fault=S013062_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013062_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013062_PE3 base=S013062_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013062_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013062_PE3: conveyor=S013062_PE3_VFD1.CTRL parent_fault=S013062_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013062_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013064_PE1 base=S013064_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013064_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013064_PE1: conveyor=S013064_PE1_VFD1.CTRL parent_fault=S013064_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013064_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013064_PE2 base=S013064_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013064_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013064_PE2: conveyor=S013064_PE2_VFD1.CTRL parent_fault=S013064_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013064_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013064_PE3 base=S013064_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013064_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013064_PE3: conveyor=S013064_PE3_VFD1.CTRL parent_fault=S013064_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013064_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013058_PE1 base=S013058_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013058_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013058_PE1: conveyor=S013058_PE1_VFD1.CTRL parent_fault=S013058_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013058_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013058_PE2 base=S013058_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013058_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013058_PE2: conveyor=S013058_PE2_VFD1.CTRL parent_fault=S013058_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013058_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013058_PE3 base=S013058_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013058_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013058_PE3: conveyor=S013058_PE3_VFD1.CTRL parent_fault=S013058_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH16:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013058_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013006_PE1 base=S013006_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013006_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013006_PE1: conveyor=S013006_PE1_VFD1.CTRL parent_fault=S013006_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013006_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013006_PE2 base=S013006_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013006_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013006_PE2: conveyor=S013006_PE2_VFD1.CTRL parent_fault=S013006_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013006_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013006_PE3 base=S013006_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013006_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013006_PE3: conveyor=S013006_PE3_VFD1.CTRL parent_fault=S013006_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013006_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013008_PE1 base=S013008_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013008_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013008_PE1: conveyor=S013008_PE1_VFD1.CTRL parent_fault=S013008_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013008_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013008_PE2 base=S013008_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013008_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013008_PE2: conveyor=S013008_PE2_VFD1.CTRL parent_fault=S013008_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013008_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013008_PE3 base=S013008_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013008_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013008_PE3: conveyor=S013008_PE3_VFD1.CTRL parent_fault=S013008_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013008_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013004_PE1 base=S013004_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013004_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013004_PE1: conveyor=S013004_PE1_VFD1.CTRL parent_fault=S013004_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013004_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013004_PE2 base=S013004_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013004_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013004_PE2: conveyor=S013004_PE2_VFD1.CTRL parent_fault=S013004_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013004_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013004_PE3 base=S013004_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013004_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013004_PE3: conveyor=S013004_PE3_VFD1.CTRL parent_fault=S013004_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH2:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013004_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013011_PE1 base=S013011_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013011_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013011_PE1: conveyor=S013011_PE1_VFD1.CTRL parent_fault=S013011_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013011_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013011_PE2 base=S013011_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013011_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013011_PE2: conveyor=S013011_PE2_VFD1.CTRL parent_fault=S013011_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013011_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013011_PE3 base=S013011_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013011_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013011_PE3: conveyor=S013011_PE3_VFD1.CTRL parent_fault=S013011_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013011_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013009_PE1 base=S013009_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013009_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013009_PE1: conveyor=S013009_PE1_VFD1.CTRL parent_fault=S013009_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013009_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013009_PE2 base=S013009_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013009_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013009_PE2: conveyor=S013009_PE2_VFD1.CTRL parent_fault=S013009_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013009_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013009_PE3 base=S013009_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013009_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013009_PE3: conveyor=S013009_PE3_VFD1.CTRL parent_fault=S013009_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013009_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013013_PE1 base=S013013_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013013_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013013_PE1: conveyor=S013013_PE1_VFD1.CTRL parent_fault=S013013_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013013_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013013_PE2 base=S013013_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013013_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013013_PE2: conveyor=S013013_PE2_VFD1.CTRL parent_fault=S013013_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013013_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013013_PE3 base=S013013_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013013_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013013_PE3: conveyor=S013013_PE3_VFD1.CTRL parent_fault=S013013_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013013_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013015_PE1 base=S013015_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013015_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013015_PE1: conveyor=S013015_PE1_VFD1.CTRL parent_fault=S013015_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013015_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013015_PE2 base=S013015_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013015_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013015_PE2: conveyor=S013015_PE2_VFD1.CTRL parent_fault=S013015_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013015_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013015_PE3 base=S013015_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013015_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013015_PE3: conveyor=S013015_PE3_VFD1.CTRL parent_fault=S013015_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH3:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013015_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013014_PE1 base=S013014_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013014_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013014_PE1: conveyor=S013014_PE1_VFD1.CTRL parent_fault=S013014_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013014_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013014_PE2 base=S013014_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013014_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013014_PE2: conveyor=S013014_PE2_VFD1.CTRL parent_fault=S013014_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013014_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013014_PE3 base=S013014_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013014_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013014_PE3: conveyor=S013014_PE3_VFD1.CTRL parent_fault=S013014_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013014_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013012_PE1 base=S013012_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013012_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013012_PE1: conveyor=S013012_PE1_VFD1.CTRL parent_fault=S013012_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013012_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013012_PE2 base=S013012_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013012_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013012_PE2: conveyor=S013012_PE2_VFD1.CTRL parent_fault=S013012_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013012_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013012_PE3 base=S013012_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013012_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013012_PE3: conveyor=S013012_PE3_VFD1.CTRL parent_fault=S013012_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013012_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013010_PE1 base=S013010_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013010_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013010_PE1: conveyor=S013010_PE1_VFD1.CTRL parent_fault=S013010_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013010_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013010_PE2 base=S013010_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013010_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013010_PE2: conveyor=S013010_PE2_VFD1.CTRL parent_fault=S013010_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013010_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013010_PE3 base=S013010_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013010_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013010_PE3: conveyor=S013010_PE3_VFD1.CTRL parent_fault=S013010_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH4:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013010_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013019_PE1 base=S013019_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013019_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013019_PE1: conveyor=S013019_PE1_VFD1.CTRL parent_fault=S013019_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013019_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013019_PE2 base=S013019_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013019_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013019_PE2: conveyor=S013019_PE2_VFD1.CTRL parent_fault=S013019_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013019_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013019_PE3 base=S013019_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013019_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013019_PE3: conveyor=S013019_PE3_VFD1.CTRL parent_fault=S013019_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013019_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013017_PE1 base=S013017_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013017_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013017_PE1: conveyor=S013017_PE1_VFD1.CTRL parent_fault=S013017_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013017_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013017_PE2 base=S013017_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013017_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013017_PE2: conveyor=S013017_PE2_VFD1.CTRL parent_fault=S013017_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013017_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013017_PE3 base=S013017_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013017_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013017_PE3: conveyor=S013017_PE3_VFD1.CTRL parent_fault=S013017_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013017_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013021_PE1 base=S013021_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013021_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013021_PE1: conveyor=S013021_PE1_VFD1.CTRL parent_fault=S013021_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013021_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013021_PE2 base=S013021_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013021_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013021_PE2: conveyor=S013021_PE2_VFD1.CTRL parent_fault=S013021_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013021_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013021_PE3 base=S013021_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013021_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013021_PE3: conveyor=S013021_PE3_VFD1.CTRL parent_fault=S013021_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013021_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013023_PE1 base=S013023_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013023_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013023_PE1: conveyor=S013023_PE1_VFD1.CTRL parent_fault=S013023_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013023_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013023_PE2 base=S013023_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013023_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013023_PE2: conveyor=S013023_PE2_VFD1.CTRL parent_fault=S013023_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013023_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013023_PE3 base=S013023_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013023_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013023_PE3: conveyor=S013023_PE3_VFD1.CTRL parent_fault=S013023_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH5:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013023_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013022_PE1 base=S013022_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013022_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013022_PE1: conveyor=S013022_PE1_VFD1.CTRL parent_fault=S013022_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013022_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013022_PE2 base=S013022_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013022_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013022_PE2: conveyor=S013022_PE2_VFD1.CTRL parent_fault=S013022_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013022_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013022_PE3 base=S013022_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013022_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013022_PE3: conveyor=S013022_PE3_VFD1.CTRL parent_fault=S013022_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013022_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013024_PE1 base=S013024_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013024_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013024_PE1: conveyor=S013024_PE1_VFD1.CTRL parent_fault=S013024_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013024_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013024_PE2 base=S013024_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013024_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013024_PE2: conveyor=S013024_PE2_VFD1.CTRL parent_fault=S013024_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013024_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013024_PE3 base=S013024_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013024_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013024_PE3: conveyor=S013024_PE3_VFD1.CTRL parent_fault=S013024_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013024_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013020_PE1 base=S013020_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013020_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013020_PE1: conveyor=S013020_PE1_VFD1.CTRL parent_fault=S013020_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013020_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013020_PE2 base=S013020_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013020_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013020_PE2: conveyor=S013020_PE2_VFD1.CTRL parent_fault=S013020_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013020_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013020_PE3 base=S013020_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013020_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013020_PE3: conveyor=S013020_PE3_VFD1.CTRL parent_fault=S013020_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013020_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013018_PE1 base=S013018_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013018_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013018_PE1: conveyor=S013018_PE1_VFD1.CTRL parent_fault=S013018_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013018_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013018_PE2 base=S013018_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013018_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013018_PE2: conveyor=S013018_PE2_VFD1.CTRL parent_fault=S013018_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013018_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013018_PE3 base=S013018_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013018_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013018_PE3: conveyor=S013018_PE3_VFD1.CTRL parent_fault=S013018_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH6:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013018_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013027_PE1 base=S013027_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013027_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013027_PE1: conveyor=S013027_PE1_VFD1.CTRL parent_fault=S013027_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013027_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013027_PE2 base=S013027_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013027_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013027_PE2: conveyor=S013027_PE2_VFD1.CTRL parent_fault=S013027_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013027_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013027_PE3 base=S013027_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013027_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013027_PE3: conveyor=S013027_PE3_VFD1.CTRL parent_fault=S013027_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013027_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013025_PE1 base=S013025_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013025_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013025_PE1: conveyor=S013025_PE1_VFD1.CTRL parent_fault=S013025_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013025_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013025_PE2 base=S013025_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013025_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013025_PE2: conveyor=S013025_PE2_VFD1.CTRL parent_fault=S013025_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013025_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013025_PE3 base=S013025_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013025_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013025_PE3: conveyor=S013025_PE3_VFD1.CTRL parent_fault=S013025_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013025_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013029_PE1 base=S013029_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013029_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013029_PE1: conveyor=S013029_PE1_VFD1.CTRL parent_fault=S013029_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013029_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013029_PE2 base=S013029_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013029_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013029_PE2: conveyor=S013029_PE2_VFD1.CTRL parent_fault=S013029_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013029_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013029_PE3 base=S013029_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013029_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013029_PE3: conveyor=S013029_PE3_VFD1.CTRL parent_fault=S013029_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013029_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013031_PE1 base=S013031_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013031_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013031_PE1: conveyor=S013031_PE1_VFD1.CTRL parent_fault=S013031_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013031_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013031_PE2 base=S013031_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013031_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013031_PE2: conveyor=S013031_PE2_VFD1.CTRL parent_fault=S013031_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013031_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013031_PE3 base=S013031_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013031_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013031_PE3: conveyor=S013031_PE3_VFD1.CTRL parent_fault=S013031_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH7:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013031_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013032_PE1 base=S013032_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013032_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013032_PE1: conveyor=S013032_PE1_VFD1.CTRL parent_fault=S013032_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013032_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013032_PE2 base=S013032_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013032_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013032_PE2: conveyor=S013032_PE2_VFD1.CTRL parent_fault=S013032_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013032_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013032_PE3 base=S013032_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013032_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013032_PE3: conveyor=S013032_PE3_VFD1.CTRL parent_fault=S013032_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013032_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013028_PE1 base=S013028_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013028_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013028_PE1: conveyor=S013028_PE1_VFD1.CTRL parent_fault=S013028_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013028_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013028_PE2 base=S013028_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013028_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013028_PE2: conveyor=S013028_PE2_VFD1.CTRL parent_fault=S013028_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013028_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013028_PE3 base=S013028_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013028_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013028_PE3: conveyor=S013028_PE3_VFD1.CTRL parent_fault=S013028_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013028_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013026_PE1 base=S013026_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013026_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013026_PE1: conveyor=S013026_PE1_VFD1.CTRL parent_fault=S013026_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013026_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013026_PE2 base=S013026_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013026_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013026_PE2: conveyor=S013026_PE2_VFD1.CTRL parent_fault=S013026_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013026_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013026_PE3 base=S013026_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013026_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013026_PE3: conveyor=S013026_PE3_VFD1.CTRL parent_fault=S013026_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH8:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013026_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013035_PE1 base=S013035_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013035_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013035_PE1: conveyor=S013035_PE1_VFD1.CTRL parent_fault=S013035_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_2_A_Pin_4 beacon=S013035_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013035_PE2 base=S013035_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013035_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013035_PE2: conveyor=S013035_PE2_VFD1.CTRL parent_fault=S013035_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_4_A_Pin_4 beacon=S013035_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013035_PE3 base=S013035_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013035_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013035_PE3: conveyor=S013035_PE3_VFD1.CTRL parent_fault=S013035_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_4_B_Pin_2 beacon=S013035_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013033_PE1 base=S013033_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013033_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013033_PE1: conveyor=S013033_PE1_VFD1.CTRL parent_fault=S013033_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_6_A_Pin_4 beacon=S013033_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013033_PE2 base=S013033_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013033_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013033_PE2: conveyor=S013033_PE2_VFD1.CTRL parent_fault=S013033_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_8_A_Pin_4 beacon=S013033_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013033_PE3 base=S013033_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013033_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013033_PE3: conveyor=S013033_PE3_VFD1.CTRL parent_fault=S013033_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_8_B_Pin_2 beacon=S013033_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013037_PE1 base=S013037_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013037_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013037_PE1: conveyor=S013037_PE1_VFD1.CTRL parent_fault=S013037_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_1_A_Pin_4 beacon=S013037_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013037_PE2 base=S013037_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013037_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013037_PE2: conveyor=S013037_PE2_VFD1.CTRL parent_fault=S013037_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_3_A_Pin_4 beacon=S013037_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013037_PE3 base=S013037_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013037_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013037_PE3: conveyor=S013037_PE3_VFD1.CTRL parent_fault=S013037_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_3_B_Pin_2 beacon=S013037_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013039_PE1 base=S013039_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013039_PE1
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013039_PE1: conveyor=S013039_PE1_VFD1.CTRL parent_fault=S013039_PE1_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_5_A_Pin_4 beacon=S013039_PE1_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013039_PE2 base=S013039_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013039_PE2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013039_PE2: conveyor=S013039_PE2_VFD1.CTRL parent_fault=S013039_PE2_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_7_A_Pin_4 beacon=S013039_PE2_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE processing S013039_PE3 base=S013039_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] No VFD found for S013039_PE3
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] FPE S013039_PE3: conveyor=S013039_PE3_VFD1.CTRL parent_fault=S013039_PE3_VFD1:I.ConnectionFaulted input=VS01C_FIOH9:I.ProcessDataIn.Connector_7_B_Pin_2 beacon=S013039_PE3_FIOH1:O.ProcessDataOut.Connector_1_B_Pin_2
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Data: FPE configs=351
|
|
[20:20:28] [DEBUG] [logging_config.py:126:_log_with_context] Extracting PMM data
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Data: PMM entries=0
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Data: PMM configs=0
|
|
[20:20:28] [DEBUG] [logging_config.py:126:_log_with_context] Extracting CB_MONITOR data
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Data: CB PDPs=0
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Data: CB configs=0
|
|
[20:20:28] [INFO] [logging_config.py:126:_log_with_context] Tags created: total=428 | standard=1 safety=3 dcs=1 modules=415
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Added 428 controller tags
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Generating main program routines...
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] Generating routine: mcm
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Successfully generated routine: mcm
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] Generating routine: rack
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Successfully generated routine: rack
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] Generating routine: dpm
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Successfully generated routine: dpm
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] Generating routine: fiom
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Successfully generated routine: fiom
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Plugin fioh cannot generate with current data
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Plugin apf cannot generate with current data
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Plugin flow_ctrl cannot generate with current data
|
|
[20:20:28] [DEBUG] [logging_config.py:126:_log_with_context] Extracting SPEED_CTRL data
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Data: SPEED_CTRL VFDs=0
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] SPEED_CTRL sample=
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Data: SPEED_CTRL count=0
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Plugin speed_ctrl cannot generate with current data
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Plugin estop_check cannot generate with current data
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Plugin encoder cannot generate with current data
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] Generating routine: safety_tag_map
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] Safety tag map: RST data has 1 rows
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] Added safety tag mapping: MCM05 -> Local:5:I.Data.0
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] Safety tag map: Generating 1 rungs
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] Generated rung 1: XIC(Local:5:I.Data.0)OTE(MCM05);
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] Safety tag map: Generated 1 total rungs
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Successfully generated routine: safety_tag_map
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] Generating routine: station_jr_pb
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Successfully generated routine: station_jr_pb
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Plugin station_s_pb cannot generate with current data
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Plugin station_ss_pb cannot generate with current data
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Plugin station_epc cannot generate with current data
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Plugin jpe cannot generate with current data
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] Generating routine: fpe
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Successfully generated routine: fpe
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Plugin pmm cannot generate with current data
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Plugin cb_monitor cannot generate with current data
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Plugin belt_tracking cannot generate with current data
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] Generating routine: main_routine
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Generating MainRoutine with JSR calls
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Successfully generated MainRoutine
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Successfully generated routine: main_routine
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Main routine generation results: {'mcm': True, 'rack': True, 'dpm': True, 'fiom': True, 'fioh': False, 'apf': False, 'flow_ctrl': False, 'speed_ctrl': False, 'estop_check': False, 'encoder': False, 'safety_tag_map': True, 'station_jr_pb': True, 'station_s_pb': False, 'station_ss_pb': False, 'station_epc': False, 'jpe': False, 'fpe': True, 'pmm': False, 'cb_monitor': False, 'belt_tracking': False, 'main_routine': True}
|
|
[20:20:28] [INFO] [logging_config.py:126:_log_with_context] Routines created (8): MainRoutine, R010_MCM, R011_RACK, R020_DPM, R030_FIOM, R090_STATION_JR_PB, R101_FPE, R130_SAFETY_TAG_MAP
|
|
[20:20:28] [INFO] [logging_config.py:126:_log_with_context] - R010_MCM: 2 rungs | example: NOP();
|
|
[20:20:28] [INFO] [logging_config.py:126:_log_with_context] - R011_RACK: 2 rungs | example: NOP();
|
|
[20:20:28] [INFO] [logging_config.py:126:_log_with_context] - R020_DPM: 3 rungs | example: NOP();
|
|
[20:20:28] [INFO] [logging_config.py:126:_log_with_context] - R030_FIOM: 32 rungs | example: NOP();
|
|
[20:20:28] [INFO] [logging_config.py:126:_log_with_context] - R130_SAFETY_TAG_MAP: 2 rungs | example: XIC(Local:5:I.Data.0)OTE(MCM_S_PB);
|
|
[20:20:28] [INFO] [logging_config.py:126:_log_with_context] - R090_STATION_JR_PB: 31 rungs | example: AOI_STATION_JR_PB(S012001_JR1_PB.AOI,S012001_JR1_PB.HMI,S012001_JR1_PB.CTRL,NO_PARTNER,VS01B_FIOM1:I.Pt04.Data,VS01B_FIOM1:O.Pt05.Data,MCM.CTRL)MOVE(S012001_...
|
|
[20:20:28] [INFO] [logging_config.py:126:_log_with_context] - R101_FPE: 351 rungs | example: AOI_FPE(S012001_PE1.AOI,S012001_PE1.HMI,S012001_PE1.CTRL,S012001_PE1_VFD1.CTRL,S012001_PE1_VFD1:I.ConnectionFaulted,VS01B_FIOH1:I.ProcessDataIn.Connector_6_A...
|
|
[20:20:28] [INFO] [logging_config.py:126:_log_with_context] - MainRoutine: 1 rungs | example: [JSR(R010_MCM,0) ,JSR(R011_RACK,0) ,JSR(R020_DPM,0) ,JSR(R030_FIOM,0) ,JSR(R130_SAFETY_TAG_MAP,0) ,JSR(R090_STATION_JR_PB,0) ,JSR(R101_FPE,0) ];
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Successfully completed ModernMainProgramGenerator generation
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Written ModernMainProgramGenerator to /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/generated_projects/SAT9_MCM05/MainProgram_Generated.L5X
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] [SUCCESS] MainProgram written to /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/generated_projects/SAT9_MCM05/MainProgram_Generated.L5X
|
|
[20:20:28] [INFO] [logging_config.py:128:_log_with_context] Generating safety tag mapping...
|
|
[20:20:28] [DEBUG] [logging_config.py:128:_log_with_context] Creating MappingWriter wrapper
|
|
[20:20:28] [DEBUG] [logging_config.py:126:_log_with_context] Creating DataLoader instance
|
|
[20:20:29] [INFO] [logging_config.py:128:_log_with_context] [SUCCESS] Safety tag mapping written to /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/generated_projects/SAT9_MCM05/SafetyTagMapping.txt
|
|
[20:20:29] [INFO] [logging_config.py:128:_log_with_context] - Safety tags: 1
|
|
[20:20:29] [INFO] [logging_config.py:128:_log_with_context] === All artifacts generated successfully! ===
|
|
{"level": "INFO", "message": "Routine generation completed successfully", "timestamp": "2025-09-04T20:20:29.102232", "module": "__main__", "file": "logging_config.py", "line": 128, "function": "_log_with_context", "pathname": "/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/Routines Generator/src/logging_config.py"}
|
|
|
|
=== Step 3: IO Tree Generator stdout ===
|
|
Enhanced MCM Generator
|
|
- Project: SAT9_MCM05
|
|
- Excel: /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/PLC Data Generator/DESC_IP_MERGED.xlsx
|
|
- Boilerplate: SAT9_boilerplate
|
|
- Mode: Single file
|
|
--------------------------------------------------
|
|
INFO: Found 512 rows with empty PARTNUMBER (will attempt inference):
|
|
Row 2: TAGNAME='VS01B_FIOM1', PARTNUMBER='[EMPTY]', DESC='S012003_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 3: TAGNAME='VS01B_FIOM1', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 4: TAGNAME='VS01B_FIOM1', PARTNUMBER='[EMPTY]', DESC='S012001_BCN1 3 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 5: TAGNAME='VS01B_FIOM1', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 6: TAGNAME='VS01B_FIOM1', PARTNUMBER='[EMPTY]', DESC='S012001_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 7: TAGNAME='VS01B_FIOM1', PARTNUMBER='[EMPTY]', DESC='S012001_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 8: TAGNAME='VS01B_FIOM1', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 9: TAGNAME='VS01B_FIOM1', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 10: TAGNAME='VS01B_FIOM1', PARTNUMBER='[EMPTY]', DESC='S012005_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 11: TAGNAME='VS01B_FIOM1', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 12: TAGNAME='VS01B_FIOM1', PARTNUMBER='[EMPTY]', DESC='S012007_BCN1 2 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 13: TAGNAME='VS01B_FIOM1', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 14: TAGNAME='VS01B_FIOM1', PARTNUMBER='[EMPTY]', DESC='VS01B_FIOH1 FIO HUB', TERM='IO12'
|
|
Row 15: TAGNAME='VS01B_FIOM1', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 16: TAGNAME='VS01B_FIOM1', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 17: TAGNAME='VS01B_FIOM1', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 18: TAGNAME='VS01B_FIOM10', PARTNUMBER='[EMPTY]', DESC='S012041_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 19: TAGNAME='VS01B_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 20: TAGNAME='VS01B_FIOM10', PARTNUMBER='[EMPTY]', DESC='S012039_BCN1 3 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 21: TAGNAME='VS01B_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 22: TAGNAME='VS01B_FIOM10', PARTNUMBER='[EMPTY]', DESC='S012039_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 23: TAGNAME='VS01B_FIOM10', PARTNUMBER='[EMPTY]', DESC='S012039_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 24: TAGNAME='VS01B_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 25: TAGNAME='VS01B_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 26: TAGNAME='VS01B_FIOM10', PARTNUMBER='[EMPTY]', DESC='S012043_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 27: TAGNAME='VS01B_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 28: TAGNAME='VS01B_FIOM10', PARTNUMBER='[EMPTY]', DESC='S012045_BCN1 2 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 29: TAGNAME='VS01B_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 30: TAGNAME='VS01B_FIOM10', PARTNUMBER='[EMPTY]', DESC='VS01B_FIOH10 FIO HUB', TERM='IO12'
|
|
Row 31: TAGNAME='VS01B_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 32: TAGNAME='VS01B_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 33: TAGNAME='VS01B_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 34: TAGNAME='VS01B_FIOM11', PARTNUMBER='[EMPTY]', DESC='S012044_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 35: TAGNAME='VS01B_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 36: TAGNAME='VS01B_FIOM11', PARTNUMBER='[EMPTY]', DESC='S012046_BCN1 2 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 37: TAGNAME='VS01B_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 38: TAGNAME='VS01B_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO04'
|
|
Row 39: TAGNAME='VS01B_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO05'
|
|
Row 40: TAGNAME='VS01B_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 41: TAGNAME='VS01B_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 42: TAGNAME='VS01B_FIOM11', PARTNUMBER='[EMPTY]', DESC='S012042_BCN1 3 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 43: TAGNAME='VS01B_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 44: TAGNAME='VS01B_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO10'
|
|
Row 45: TAGNAME='VS01B_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 46: TAGNAME='VS01B_FIOM11', PARTNUMBER='[EMPTY]', DESC='VS01B_FIOH11 FIO HUB', TERM='IO12'
|
|
Row 47: TAGNAME='VS01B_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 48: TAGNAME='VS01B_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 49: TAGNAME='VS01B_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 50: TAGNAME='VS01B_FIOM12', PARTNUMBER='[EMPTY]', DESC='S012049_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 51: TAGNAME='VS01B_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 52: TAGNAME='VS01B_FIOM12', PARTNUMBER='[EMPTY]', DESC='S012047_BCN1 3 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 53: TAGNAME='VS01B_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 54: TAGNAME='VS01B_FIOM12', PARTNUMBER='[EMPTY]', DESC='S012047_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 55: TAGNAME='VS01B_FIOM12', PARTNUMBER='[EMPTY]', DESC='S012047_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 56: TAGNAME='VS01B_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 57: TAGNAME='VS01B_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 58: TAGNAME='VS01B_FIOM12', PARTNUMBER='[EMPTY]', DESC='S012051_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 59: TAGNAME='VS01B_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 60: TAGNAME='VS01B_FIOM12', PARTNUMBER='[EMPTY]', DESC='S012053_BCN1 2 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 61: TAGNAME='VS01B_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 62: TAGNAME='VS01B_FIOM12', PARTNUMBER='[EMPTY]', DESC='VS01B_FIOH12 FIO HUB', TERM='IO12'
|
|
Row 63: TAGNAME='VS01B_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 64: TAGNAME='VS01B_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 65: TAGNAME='VS01B_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 66: TAGNAME='VS01B_FIOM13', PARTNUMBER='[EMPTY]', DESC='S012052_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 67: TAGNAME='VS01B_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 68: TAGNAME='VS01B_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO02'
|
|
Row 69: TAGNAME='VS01B_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 70: TAGNAME='VS01B_FIOM13', PARTNUMBER='[EMPTY]', DESC='S012048_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 71: TAGNAME='VS01B_FIOM13', PARTNUMBER='[EMPTY]', DESC='S012048_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 72: TAGNAME='VS01B_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 73: TAGNAME='VS01B_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 74: TAGNAME='VS01B_FIOM13', PARTNUMBER='[EMPTY]', DESC='S012050_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 75: TAGNAME='VS01B_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 76: TAGNAME='VS01B_FIOM13', PARTNUMBER='[EMPTY]', DESC='S012048_BCN1 3 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 77: TAGNAME='VS01B_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 78: TAGNAME='VS01B_FIOM13', PARTNUMBER='[EMPTY]', DESC='VS01B_FIOH13 FIO HUB', TERM='IO12'
|
|
Row 79: TAGNAME='VS01B_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 80: TAGNAME='VS01B_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 81: TAGNAME='VS01B_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 82: TAGNAME='VS01B_FIOM14', PARTNUMBER='[EMPTY]', DESC='S012057_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 83: TAGNAME='VS01B_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 84: TAGNAME='VS01B_FIOM14', PARTNUMBER='[EMPTY]', DESC='S012055_BCN1 3 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 85: TAGNAME='VS01B_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 86: TAGNAME='VS01B_FIOM14', PARTNUMBER='[EMPTY]', DESC='S012055_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 87: TAGNAME='VS01B_FIOM14', PARTNUMBER='[EMPTY]', DESC='S012055_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 88: TAGNAME='VS01B_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 89: TAGNAME='VS01B_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 90: TAGNAME='VS01B_FIOM14', PARTNUMBER='[EMPTY]', DESC='S012059_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 91: TAGNAME='VS01B_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 92: TAGNAME='VS01B_FIOM14', PARTNUMBER='[EMPTY]', DESC='S012061_BCN1 2 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 93: TAGNAME='VS01B_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 94: TAGNAME='VS01B_FIOM14', PARTNUMBER='[EMPTY]', DESC='VS01B_FIOH14 FIO HUB', TERM='IO12'
|
|
Row 95: TAGNAME='VS01B_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 96: TAGNAME='VS01B_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 97: TAGNAME='VS01B_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 98: TAGNAME='VS01B_FIOM15', PARTNUMBER='[EMPTY]', DESC='S012060_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 99: TAGNAME='VS01B_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 100: TAGNAME='VS01B_FIOM15', PARTNUMBER='[EMPTY]', DESC='S012062_BCN1 2 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 101: TAGNAME='VS01B_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 102: TAGNAME='VS01B_FIOM15', PARTNUMBER='[EMPTY]', DESC='S012056_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 103: TAGNAME='VS01B_FIOM15', PARTNUMBER='[EMPTY]', DESC='S012056_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 104: TAGNAME='VS01B_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 105: TAGNAME='VS01B_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 106: TAGNAME='VS01B_FIOM15', PARTNUMBER='[EMPTY]', DESC='S012058_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 107: TAGNAME='VS01B_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 108: TAGNAME='VS01B_FIOM15', PARTNUMBER='[EMPTY]', DESC='S012056_BCN1 3 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 109: TAGNAME='VS01B_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 110: TAGNAME='VS01B_FIOM15', PARTNUMBER='[EMPTY]', DESC='VS01B_FIOH15 FIO HUB', TERM='IO12'
|
|
Row 111: TAGNAME='VS01B_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 112: TAGNAME='VS01B_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 113: TAGNAME='VS01B_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 114: TAGNAME='VS01B_FIOM16', PARTNUMBER='[EMPTY]', DESC='S012065_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 115: TAGNAME='VS01B_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 116: TAGNAME='VS01B_FIOM16', PARTNUMBER='[EMPTY]', DESC='S012063_BCN1 3 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 117: TAGNAME='VS01B_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 118: TAGNAME='VS01B_FIOM16', PARTNUMBER='[EMPTY]', DESC='S012063_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 119: TAGNAME='VS01B_FIOM16', PARTNUMBER='[EMPTY]', DESC='S012063_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 120: TAGNAME='VS01B_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 121: TAGNAME='VS01B_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 122: TAGNAME='VS01B_FIOM16', PARTNUMBER='[EMPTY]', DESC='S012067_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 123: TAGNAME='VS01B_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 124: TAGNAME='VS01B_FIOM16', PARTNUMBER='[EMPTY]', DESC='S012069_BCN1 2 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 125: TAGNAME='VS01B_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 126: TAGNAME='VS01B_FIOM16', PARTNUMBER='[EMPTY]', DESC='VS01B_FIOH16 FIO HUB', TERM='IO12'
|
|
Row 127: TAGNAME='VS01B_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 128: TAGNAME='VS01B_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 129: TAGNAME='VS01B_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 130: TAGNAME='VS01B_FIOM17', PARTNUMBER='[EMPTY]', DESC='S012068_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 131: TAGNAME='VS01B_FIOM17', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 132: TAGNAME='VS01B_FIOM17', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO02'
|
|
Row 133: TAGNAME='VS01B_FIOM17', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 134: TAGNAME='VS01B_FIOM17', PARTNUMBER='[EMPTY]', DESC='S012064_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 135: TAGNAME='VS01B_FIOM17', PARTNUMBER='[EMPTY]', DESC='S012064_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 136: TAGNAME='VS01B_FIOM17', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 137: TAGNAME='VS01B_FIOM17', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 138: TAGNAME='VS01B_FIOM17', PARTNUMBER='[EMPTY]', DESC='S012066_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 139: TAGNAME='VS01B_FIOM17', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 140: TAGNAME='VS01B_FIOM17', PARTNUMBER='[EMPTY]', DESC='S012064_BCN1 3 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 141: TAGNAME='VS01B_FIOM17', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 142: TAGNAME='VS01B_FIOM17', PARTNUMBER='[EMPTY]', DESC='VS01B_FIOH17 FIO HUB', TERM='IO12'
|
|
Row 143: TAGNAME='VS01B_FIOM17', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 144: TAGNAME='VS01B_FIOM17', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 145: TAGNAME='VS01B_FIOM17', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 146: TAGNAME='VS01B_FIOM2', PARTNUMBER='[EMPTY]', DESC='S012006_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 147: TAGNAME='VS01B_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 148: TAGNAME='VS01B_FIOM2', PARTNUMBER='[EMPTY]', DESC='S012008_BCN1 2 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 149: TAGNAME='VS01B_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 150: TAGNAME='VS01B_FIOM2', PARTNUMBER='[EMPTY]', DESC='S012002_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 151: TAGNAME='VS01B_FIOM2', PARTNUMBER='[EMPTY]', DESC='S012002_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 152: TAGNAME='VS01B_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 153: TAGNAME='VS01B_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 154: TAGNAME='VS01B_FIOM2', PARTNUMBER='[EMPTY]', DESC='S012004_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 155: TAGNAME='VS01B_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 156: TAGNAME='VS01B_FIOM2', PARTNUMBER='[EMPTY]', DESC='S012002_BCN1 3 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 157: TAGNAME='VS01B_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 158: TAGNAME='VS01B_FIOM2', PARTNUMBER='[EMPTY]', DESC='VS01B_FIOH2 FIO HUB', TERM='IO12'
|
|
Row 159: TAGNAME='VS01B_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 160: TAGNAME='VS01B_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 161: TAGNAME='VS01B_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 162: TAGNAME='VS01B_FIOM3', PARTNUMBER='[EMPTY]', DESC='S012018_BCN1 3 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 163: TAGNAME='VS01B_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 164: TAGNAME='VS01B_FIOM3', PARTNUMBER='[EMPTY]', DESC='S012020_BCN1 2 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 165: TAGNAME='VS01B_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 166: TAGNAME='VS01B_FIOM3', PARTNUMBER='[EMPTY]', DESC='S012014_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 167: TAGNAME='VS01B_FIOM3', PARTNUMBER='[EMPTY]', DESC='S012014_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 168: TAGNAME='VS01B_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 169: TAGNAME='VS01B_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 170: TAGNAME='VS01B_FIOM3', PARTNUMBER='[EMPTY]', DESC='S012016_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 171: TAGNAME='VS01B_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 172: TAGNAME='VS01B_FIOM3', PARTNUMBER='[EMPTY]', DESC='S012014_BCN1 3 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 173: TAGNAME='VS01B_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 174: TAGNAME='VS01B_FIOM3', PARTNUMBER='[EMPTY]', DESC='VS01B_FIOH3 FIO HUB', TERM='IO12'
|
|
Row 175: TAGNAME='VS01B_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 176: TAGNAME='VS01B_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 177: TAGNAME='VS01B_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 178: TAGNAME='VS01B_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO00'
|
|
Row 179: TAGNAME='VS01B_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 180: TAGNAME='VS01B_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO02'
|
|
Row 181: TAGNAME='VS01B_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 182: TAGNAME='VS01B_FIOM4', PARTNUMBER='[EMPTY]', DESC='S012022_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 183: TAGNAME='VS01B_FIOM4', PARTNUMBER='[EMPTY]', DESC='S012022_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 184: TAGNAME='VS01B_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 185: TAGNAME='VS01B_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 186: TAGNAME='VS01B_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO08'
|
|
Row 187: TAGNAME='VS01B_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 188: TAGNAME='VS01B_FIOM4', PARTNUMBER='[EMPTY]', DESC='S012022_BCN1 2 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 189: TAGNAME='VS01B_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 190: TAGNAME='VS01B_FIOM4', PARTNUMBER='[EMPTY]', DESC='VS01B_FIOH4 FIO HUB', TERM='IO12'
|
|
Row 191: TAGNAME='VS01B_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 192: TAGNAME='VS01B_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 193: TAGNAME='VS01B_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 194: TAGNAME='VS01B_FIOM5', PARTNUMBER='[EMPTY]', DESC='S012025_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 195: TAGNAME='VS01B_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 196: TAGNAME='VS01B_FIOM5', PARTNUMBER='[EMPTY]', DESC='S012023_BCN1 2 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 197: TAGNAME='VS01B_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 198: TAGNAME='VS01B_FIOM5', PARTNUMBER='[EMPTY]', DESC='S012023_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 199: TAGNAME='VS01B_FIOM5', PARTNUMBER='[EMPTY]', DESC='S012023_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 200: TAGNAME='VS01B_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 201: TAGNAME='VS01B_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 202: TAGNAME='VS01B_FIOM5', PARTNUMBER='[EMPTY]', DESC='S012027_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 203: TAGNAME='VS01B_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 204: TAGNAME='VS01B_FIOM5', PARTNUMBER='[EMPTY]', DESC='S012029_BCN1 2 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 205: TAGNAME='VS01B_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 206: TAGNAME='VS01B_FIOM5', PARTNUMBER='[EMPTY]', DESC='VS01B_FIOH5 FIO HUB', TERM='IO12'
|
|
Row 207: TAGNAME='VS01B_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 208: TAGNAME='VS01B_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 209: TAGNAME='VS01B_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 210: TAGNAME='VS01B_FIOM6', PARTNUMBER='[EMPTY]', DESC='S012028_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 211: TAGNAME='VS01B_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 212: TAGNAME='VS01B_FIOM6', PARTNUMBER='[EMPTY]', DESC='S012030_BCN1 2 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 213: TAGNAME='VS01B_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 214: TAGNAME='VS01B_FIOM6', PARTNUMBER='[EMPTY]', DESC='S012024_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 215: TAGNAME='VS01B_FIOM6', PARTNUMBER='[EMPTY]', DESC='S012024_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 216: TAGNAME='VS01B_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 217: TAGNAME='VS01B_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 218: TAGNAME='VS01B_FIOM6', PARTNUMBER='[EMPTY]', DESC='S012026_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 219: TAGNAME='VS01B_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 220: TAGNAME='VS01B_FIOM6', PARTNUMBER='[EMPTY]', DESC='S012024_BCN1 3 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 221: TAGNAME='VS01B_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 222: TAGNAME='VS01B_FIOM6', PARTNUMBER='[EMPTY]', DESC='VS01B_FIOH6 FIO HUB', TERM='IO12'
|
|
Row 223: TAGNAME='VS01B_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 224: TAGNAME='VS01B_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 225: TAGNAME='VS01B_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 226: TAGNAME='VS01B_FIOM7', PARTNUMBER='[EMPTY]', DESC='S012033_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 227: TAGNAME='VS01B_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 228: TAGNAME='VS01B_FIOM7', PARTNUMBER='[EMPTY]', DESC='S012031_BCN1 3 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 229: TAGNAME='VS01B_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 230: TAGNAME='VS01B_FIOM7', PARTNUMBER='[EMPTY]', DESC='S012031_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 231: TAGNAME='VS01B_FIOM7', PARTNUMBER='[EMPTY]', DESC='S012031_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 232: TAGNAME='VS01B_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 233: TAGNAME='VS01B_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 234: TAGNAME='VS01B_FIOM7', PARTNUMBER='[EMPTY]', DESC='S012035_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 235: TAGNAME='VS01B_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 236: TAGNAME='VS01B_FIOM7', PARTNUMBER='[EMPTY]', DESC='S012037_BCN1 2 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 237: TAGNAME='VS01B_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 238: TAGNAME='VS01B_FIOM7', PARTNUMBER='[EMPTY]', DESC='VS01B_FIOH7 FIO HUB', TERM='IO12'
|
|
Row 239: TAGNAME='VS01B_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 240: TAGNAME='VS01B_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 241: TAGNAME='VS01B_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 242: TAGNAME='VS01B_FIOM8', PARTNUMBER='[EMPTY]', DESC='S012036_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 243: TAGNAME='VS01B_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 244: TAGNAME='VS01B_FIOM8', PARTNUMBER='[EMPTY]', DESC='S012038_BCN1 2 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 245: TAGNAME='VS01B_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 246: TAGNAME='VS01B_FIOM8', PARTNUMBER='[EMPTY]', DESC='S012032_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 247: TAGNAME='VS01B_FIOM8', PARTNUMBER='[EMPTY]', DESC='S012032_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 248: TAGNAME='VS01B_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 249: TAGNAME='VS01B_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 250: TAGNAME='VS01B_FIOM8', PARTNUMBER='[EMPTY]', DESC='S012034_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 251: TAGNAME='VS01B_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 252: TAGNAME='VS01B_FIOM8', PARTNUMBER='[EMPTY]', DESC='S012032_BCN1 3 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 253: TAGNAME='VS01B_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 254: TAGNAME='VS01B_FIOM8', PARTNUMBER='[EMPTY]', DESC='VS01B_FIOH8 FIO HUB', TERM='IO12'
|
|
Row 255: TAGNAME='VS01B_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 256: TAGNAME='VS01B_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 257: TAGNAME='VS01B_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 258: TAGNAME='VS01C_FIOM1', PARTNUMBER='[EMPTY]', DESC='S013003_BCN1 3 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 259: TAGNAME='VS01C_FIOM1', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 260: TAGNAME='VS01C_FIOM1', PARTNUMBER='[EMPTY]', DESC='S013001_BCN1 3 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 261: TAGNAME='VS01C_FIOM1', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 262: TAGNAME='VS01C_FIOM1', PARTNUMBER='[EMPTY]', DESC='S013001_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 263: TAGNAME='VS01C_FIOM1', PARTNUMBER='[EMPTY]', DESC='S013001_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 264: TAGNAME='VS01C_FIOM1', PARTNUMBER='[EMPTY]', DESC='S013003_JR1_PB JAM RESET PUSHBUTTON', TERM='IO06'
|
|
Row 265: TAGNAME='VS01C_FIOM1', PARTNUMBER='[EMPTY]', DESC='S013003_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO07'
|
|
Row 266: TAGNAME='VS01C_FIOM1', PARTNUMBER='[EMPTY]', DESC='S013005_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 267: TAGNAME='VS01C_FIOM1', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 268: TAGNAME='VS01C_FIOM1', PARTNUMBER='[EMPTY]', DESC='S013007_BCN1 2 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 269: TAGNAME='VS01C_FIOM1', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 270: TAGNAME='VS01C_FIOM1', PARTNUMBER='[EMPTY]', DESC='VS01C_FIOH1 FIO HUB', TERM='IO12'
|
|
Row 271: TAGNAME='VS01C_FIOM1', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 272: TAGNAME='VS01C_FIOM1', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 273: TAGNAME='VS01C_FIOM1', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 274: TAGNAME='VS01C_FIOM10', PARTNUMBER='[EMPTY]', DESC='S013038_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 275: TAGNAME='VS01C_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 276: TAGNAME='VS01C_FIOM10', PARTNUMBER='[EMPTY]', DESC='S013040_BCN1 2 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 277: TAGNAME='VS01C_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 278: TAGNAME='VS01C_FIOM10', PARTNUMBER='[EMPTY]', DESC='S013034_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 279: TAGNAME='VS01C_FIOM10', PARTNUMBER='[EMPTY]', DESC='S013034_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 280: TAGNAME='VS01C_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 281: TAGNAME='VS01C_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 282: TAGNAME='VS01C_FIOM10', PARTNUMBER='[EMPTY]', DESC='S013036_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 283: TAGNAME='VS01C_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 284: TAGNAME='VS01C_FIOM10', PARTNUMBER='[EMPTY]', DESC='S013034_BCN1 3 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 285: TAGNAME='VS01C_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 286: TAGNAME='VS01C_FIOM10', PARTNUMBER='[EMPTY]', DESC='VS01C_FIOH10 FIO HUB', TERM='IO12'
|
|
Row 287: TAGNAME='VS01C_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 288: TAGNAME='VS01C_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 289: TAGNAME='VS01C_FIOM10', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 290: TAGNAME='VS01C_FIOM11', PARTNUMBER='[EMPTY]', DESC='S013043_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 291: TAGNAME='VS01C_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 292: TAGNAME='VS01C_FIOM11', PARTNUMBER='[EMPTY]', DESC='S013041_BCN1 3 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 293: TAGNAME='VS01C_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 294: TAGNAME='VS01C_FIOM11', PARTNUMBER='[EMPTY]', DESC='S013041_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 295: TAGNAME='VS01C_FIOM11', PARTNUMBER='[EMPTY]', DESC='S013041_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 296: TAGNAME='VS01C_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 297: TAGNAME='VS01C_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 298: TAGNAME='VS01C_FIOM11', PARTNUMBER='[EMPTY]', DESC='S013045_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 299: TAGNAME='VS01C_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 300: TAGNAME='VS01C_FIOM11', PARTNUMBER='[EMPTY]', DESC='S013047_BCN1 2 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 301: TAGNAME='VS01C_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 302: TAGNAME='VS01C_FIOM11', PARTNUMBER='[EMPTY]', DESC='VS01C_FIOH11 FIO HUB', TERM='IO12'
|
|
Row 303: TAGNAME='VS01C_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 304: TAGNAME='VS01C_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 305: TAGNAME='VS01C_FIOM11', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 306: TAGNAME='VS01C_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO00'
|
|
Row 307: TAGNAME='VS01C_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 308: TAGNAME='VS01C_FIOM12', PARTNUMBER='[EMPTY]', DESC='S013048_BCN1 2 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 309: TAGNAME='VS01C_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 310: TAGNAME='VS01C_FIOM12', PARTNUMBER='[EMPTY]', DESC='S013042_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 311: TAGNAME='VS01C_FIOM12', PARTNUMBER='[EMPTY]', DESC='S013042_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 312: TAGNAME='VS01C_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 313: TAGNAME='VS01C_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 314: TAGNAME='VS01C_FIOM12', PARTNUMBER='[EMPTY]', DESC='S013044_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 315: TAGNAME='VS01C_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 316: TAGNAME='VS01C_FIOM12', PARTNUMBER='[EMPTY]', DESC='S013042_BCN1 3 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 317: TAGNAME='VS01C_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 318: TAGNAME='VS01C_FIOM12', PARTNUMBER='[EMPTY]', DESC='VS01C_FIOH12 FIO HUB', TERM='IO12'
|
|
Row 319: TAGNAME='VS01C_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 320: TAGNAME='VS01C_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 321: TAGNAME='VS01C_FIOM12', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 322: TAGNAME='VS01C_FIOM13', PARTNUMBER='[EMPTY]', DESC='S013051_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 323: TAGNAME='VS01C_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 324: TAGNAME='VS01C_FIOM13', PARTNUMBER='[EMPTY]', DESC='S013049_BCN1 3 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 325: TAGNAME='VS01C_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 326: TAGNAME='VS01C_FIOM13', PARTNUMBER='[EMPTY]', DESC='S013049_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 327: TAGNAME='VS01C_FIOM13', PARTNUMBER='[EMPTY]', DESC='S013049_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 328: TAGNAME='VS01C_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 329: TAGNAME='VS01C_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 330: TAGNAME='VS01C_FIOM13', PARTNUMBER='[EMPTY]', DESC='S013053_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 331: TAGNAME='VS01C_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 332: TAGNAME='VS01C_FIOM13', PARTNUMBER='[EMPTY]', DESC='S013055_BCN1 2 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 333: TAGNAME='VS01C_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 334: TAGNAME='VS01C_FIOM13', PARTNUMBER='[EMPTY]', DESC='VS01C_FIOH13 FIO HUB', TERM='IO12'
|
|
Row 335: TAGNAME='VS01C_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 336: TAGNAME='VS01C_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 337: TAGNAME='VS01C_FIOM13', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 338: TAGNAME='VS01C_FIOM14', PARTNUMBER='[EMPTY]', DESC='S013054_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 339: TAGNAME='VS01C_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 340: TAGNAME='VS01C_FIOM14', PARTNUMBER='[EMPTY]', DESC='S013056_BCN1 2 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 341: TAGNAME='VS01C_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 342: TAGNAME='VS01C_FIOM14', PARTNUMBER='[EMPTY]', DESC='S013050_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 343: TAGNAME='VS01C_FIOM14', PARTNUMBER='[EMPTY]', DESC='S013050_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 344: TAGNAME='VS01C_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 345: TAGNAME='VS01C_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 346: TAGNAME='VS01C_FIOM14', PARTNUMBER='[EMPTY]', DESC='S013052_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 347: TAGNAME='VS01C_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 348: TAGNAME='VS01C_FIOM14', PARTNUMBER='[EMPTY]', DESC='S013050_BCN1 3 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 349: TAGNAME='VS01C_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 350: TAGNAME='VS01C_FIOM14', PARTNUMBER='[EMPTY]', DESC='VS01C_FIOH14 FIO HUB', TERM='IO12'
|
|
Row 351: TAGNAME='VS01C_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 352: TAGNAME='VS01C_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 353: TAGNAME='VS01C_FIOM14', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 354: TAGNAME='VS01C_FIOM15', PARTNUMBER='[EMPTY]', DESC='S013059_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 355: TAGNAME='VS01C_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 356: TAGNAME='VS01C_FIOM15', PARTNUMBER='[EMPTY]', DESC='S013057_BCN1 3 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 357: TAGNAME='VS01C_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 358: TAGNAME='VS01C_FIOM15', PARTNUMBER='[EMPTY]', DESC='S013057_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 359: TAGNAME='VS01C_FIOM15', PARTNUMBER='[EMPTY]', DESC='S013057_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 360: TAGNAME='VS01C_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 361: TAGNAME='VS01C_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 362: TAGNAME='VS01C_FIOM15', PARTNUMBER='[EMPTY]', DESC='S013061_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 363: TAGNAME='VS01C_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 364: TAGNAME='VS01C_FIOM15', PARTNUMBER='[EMPTY]', DESC='S013063_BCN1 2 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 365: TAGNAME='VS01C_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 366: TAGNAME='VS01C_FIOM15', PARTNUMBER='[EMPTY]', DESC='VS01C_FIOH15 FIO HUB', TERM='IO12'
|
|
Row 367: TAGNAME='VS01C_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 368: TAGNAME='VS01C_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 369: TAGNAME='VS01C_FIOM15', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 370: TAGNAME='VS01C_FIOM16', PARTNUMBER='[EMPTY]', DESC='S013062_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 371: TAGNAME='VS01C_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 372: TAGNAME='VS01C_FIOM16', PARTNUMBER='[EMPTY]', DESC='S013064_BCN1 2 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 373: TAGNAME='VS01C_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 374: TAGNAME='VS01C_FIOM16', PARTNUMBER='[EMPTY]', DESC='S013058_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 375: TAGNAME='VS01C_FIOM16', PARTNUMBER='[EMPTY]', DESC='S013058_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 376: TAGNAME='VS01C_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 377: TAGNAME='VS01C_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 378: TAGNAME='VS01C_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO08'
|
|
Row 379: TAGNAME='VS01C_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 380: TAGNAME='VS01C_FIOM16', PARTNUMBER='[EMPTY]', DESC='S013058_BCN1 3 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 381: TAGNAME='VS01C_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 382: TAGNAME='VS01C_FIOM16', PARTNUMBER='[EMPTY]', DESC='VS01C_FIOH16 FIO HUB', TERM='IO12'
|
|
Row 383: TAGNAME='VS01C_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 384: TAGNAME='VS01C_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 385: TAGNAME='VS01C_FIOM16', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 386: TAGNAME='VS01C_FIOM2', PARTNUMBER='[EMPTY]', DESC='S013006_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 387: TAGNAME='VS01C_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 388: TAGNAME='VS01C_FIOM2', PARTNUMBER='[EMPTY]', DESC='S013008_BCN1 2 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 389: TAGNAME='VS01C_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 390: TAGNAME='VS01C_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO04'
|
|
Row 391: TAGNAME='VS01C_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO05'
|
|
Row 392: TAGNAME='VS01C_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 393: TAGNAME='VS01C_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 394: TAGNAME='VS01C_FIOM2', PARTNUMBER='[EMPTY]', DESC='S013004_BCN1 3 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 395: TAGNAME='VS01C_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 396: TAGNAME='VS01C_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO10'
|
|
Row 397: TAGNAME='VS01C_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 398: TAGNAME='VS01C_FIOM2', PARTNUMBER='[EMPTY]', DESC='VS01C_FIOH2 FIO HUB', TERM='IO12'
|
|
Row 399: TAGNAME='VS01C_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 400: TAGNAME='VS01C_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 401: TAGNAME='VS01C_FIOM2', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 402: TAGNAME='VS01C_FIOM3', PARTNUMBER='[EMPTY]', DESC='S013011_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 403: TAGNAME='VS01C_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 404: TAGNAME='VS01C_FIOM3', PARTNUMBER='[EMPTY]', DESC='S013009_BCN1 3 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 405: TAGNAME='VS01C_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 406: TAGNAME='VS01C_FIOM3', PARTNUMBER='[EMPTY]', DESC='S013009_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 407: TAGNAME='VS01C_FIOM3', PARTNUMBER='[EMPTY]', DESC='S013009_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 408: TAGNAME='VS01C_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 409: TAGNAME='VS01C_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 410: TAGNAME='VS01C_FIOM3', PARTNUMBER='[EMPTY]', DESC='S013013_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 411: TAGNAME='VS01C_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 412: TAGNAME='VS01C_FIOM3', PARTNUMBER='[EMPTY]', DESC='S013015_BCN1 2 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 413: TAGNAME='VS01C_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 414: TAGNAME='VS01C_FIOM3', PARTNUMBER='[EMPTY]', DESC='VS01C_FIOH3 FIO HUB', TERM='IO12'
|
|
Row 415: TAGNAME='VS01C_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 416: TAGNAME='VS01C_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 417: TAGNAME='VS01C_FIOM3', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 418: TAGNAME='VS01C_FIOM4', PARTNUMBER='[EMPTY]', DESC='S013014_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 419: TAGNAME='VS01C_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 420: TAGNAME='VS01C_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO02'
|
|
Row 421: TAGNAME='VS01C_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 422: TAGNAME='VS01C_FIOM4', PARTNUMBER='[EMPTY]', DESC='S013010_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 423: TAGNAME='VS01C_FIOM4', PARTNUMBER='[EMPTY]', DESC='S013010_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 424: TAGNAME='VS01C_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 425: TAGNAME='VS01C_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 426: TAGNAME='VS01C_FIOM4', PARTNUMBER='[EMPTY]', DESC='S013012_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 427: TAGNAME='VS01C_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 428: TAGNAME='VS01C_FIOM4', PARTNUMBER='[EMPTY]', DESC='S013010_BCN1 3 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 429: TAGNAME='VS01C_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 430: TAGNAME='VS01C_FIOM4', PARTNUMBER='[EMPTY]', DESC='VS01C_FIOH4 FIO HUB', TERM='IO12'
|
|
Row 431: TAGNAME='VS01C_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 432: TAGNAME='VS01C_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 433: TAGNAME='VS01C_FIOM4', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 434: TAGNAME='VS01C_FIOM5', PARTNUMBER='[EMPTY]', DESC='S013019_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 435: TAGNAME='VS01C_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 436: TAGNAME='VS01C_FIOM5', PARTNUMBER='[EMPTY]', DESC='S013017_BCN1 3 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 437: TAGNAME='VS01C_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 438: TAGNAME='VS01C_FIOM5', PARTNUMBER='[EMPTY]', DESC='S013017_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 439: TAGNAME='VS01C_FIOM5', PARTNUMBER='[EMPTY]', DESC='S013017_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 440: TAGNAME='VS01C_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 441: TAGNAME='VS01C_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 442: TAGNAME='VS01C_FIOM5', PARTNUMBER='[EMPTY]', DESC='S013021_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 443: TAGNAME='VS01C_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 444: TAGNAME='VS01C_FIOM5', PARTNUMBER='[EMPTY]', DESC='S013023_BCN1 2 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 445: TAGNAME='VS01C_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 446: TAGNAME='VS01C_FIOM5', PARTNUMBER='[EMPTY]', DESC='VS01C_FIOH5 FIO HUB', TERM='IO12'
|
|
Row 447: TAGNAME='VS01C_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 448: TAGNAME='VS01C_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 449: TAGNAME='VS01C_FIOM5', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 450: TAGNAME='VS01C_FIOM6', PARTNUMBER='[EMPTY]', DESC='S013022_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 451: TAGNAME='VS01C_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 452: TAGNAME='VS01C_FIOM6', PARTNUMBER='[EMPTY]', DESC='S013024_BCN1 2 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 453: TAGNAME='VS01C_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 454: TAGNAME='VS01C_FIOM6', PARTNUMBER='[EMPTY]', DESC='S013018_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 455: TAGNAME='VS01C_FIOM6', PARTNUMBER='[EMPTY]', DESC='S013018_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 456: TAGNAME='VS01C_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 457: TAGNAME='VS01C_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 458: TAGNAME='VS01C_FIOM6', PARTNUMBER='[EMPTY]', DESC='S013020_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 459: TAGNAME='VS01C_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 460: TAGNAME='VS01C_FIOM6', PARTNUMBER='[EMPTY]', DESC='S013018_BCN1 3 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 461: TAGNAME='VS01C_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 462: TAGNAME='VS01C_FIOM6', PARTNUMBER='[EMPTY]', DESC='VS01C_FIOH6 FIO HUB', TERM='IO12'
|
|
Row 463: TAGNAME='VS01C_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 464: TAGNAME='VS01C_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 465: TAGNAME='VS01C_FIOM6', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 466: TAGNAME='VS01C_FIOM7', PARTNUMBER='[EMPTY]', DESC='S013027_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 467: TAGNAME='VS01C_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 468: TAGNAME='VS01C_FIOM7', PARTNUMBER='[EMPTY]', DESC='S013025_BCN1 3 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 469: TAGNAME='VS01C_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 470: TAGNAME='VS01C_FIOM7', PARTNUMBER='[EMPTY]', DESC='S013025_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 471: TAGNAME='VS01C_FIOM7', PARTNUMBER='[EMPTY]', DESC='S013025_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 472: TAGNAME='VS01C_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 473: TAGNAME='VS01C_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 474: TAGNAME='VS01C_FIOM7', PARTNUMBER='[EMPTY]', DESC='S013029_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 475: TAGNAME='VS01C_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 476: TAGNAME='VS01C_FIOM7', PARTNUMBER='[EMPTY]', DESC='S013031_BCN1 2 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 477: TAGNAME='VS01C_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 478: TAGNAME='VS01C_FIOM7', PARTNUMBER='[EMPTY]', DESC='VS01C_FIOH7 FIO HUB', TERM='IO12'
|
|
Row 479: TAGNAME='VS01C_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 480: TAGNAME='VS01C_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 481: TAGNAME='VS01C_FIOM7', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 482: TAGNAME='VS01C_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO00'
|
|
Row 483: TAGNAME='VS01C_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 484: TAGNAME='VS01C_FIOM8', PARTNUMBER='[EMPTY]', DESC='S013032_BCN1 2 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 485: TAGNAME='VS01C_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 486: TAGNAME='VS01C_FIOM8', PARTNUMBER='[EMPTY]', DESC='S013026_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 487: TAGNAME='VS01C_FIOM8', PARTNUMBER='[EMPTY]', DESC='S013026_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 488: TAGNAME='VS01C_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 489: TAGNAME='VS01C_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 490: TAGNAME='VS01C_FIOM8', PARTNUMBER='[EMPTY]', DESC='S013028_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 491: TAGNAME='VS01C_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 492: TAGNAME='VS01C_FIOM8', PARTNUMBER='[EMPTY]', DESC='S013026_BCN1 3 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 493: TAGNAME='VS01C_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 494: TAGNAME='VS01C_FIOM8', PARTNUMBER='[EMPTY]', DESC='VS01C_FIOH8 FIO HUB', TERM='IO12'
|
|
Row 495: TAGNAME='VS01C_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 496: TAGNAME='VS01C_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 497: TAGNAME='VS01C_FIOM8', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Row 498: TAGNAME='VS01C_FIOM9', PARTNUMBER='[EMPTY]', DESC='S013035_BCN1 2 STACK IOLINK BEACON', TERM='IO00'
|
|
Row 499: TAGNAME='VS01C_FIOM9', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO01'
|
|
Row 500: TAGNAME='VS01C_FIOM9', PARTNUMBER='[EMPTY]', DESC='S013033_BCN1 3 STACK IOLINK BEACON', TERM='IO02'
|
|
Row 501: TAGNAME='VS01C_FIOM9', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO03'
|
|
Row 502: TAGNAME='VS01C_FIOM9', PARTNUMBER='[EMPTY]', DESC='S013033_JR1_PB JAM RESET PUSHBUTTON', TERM='IO04'
|
|
Row 503: TAGNAME='VS01C_FIOM9', PARTNUMBER='[EMPTY]', DESC='S013033_JR1_PB_LT JAM RESET PUSHBUTTON LIGHT', TERM='IO05'
|
|
Row 504: TAGNAME='VS01C_FIOM9', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO06'
|
|
Row 505: TAGNAME='VS01C_FIOM9', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO07'
|
|
Row 506: TAGNAME='VS01C_FIOM9', PARTNUMBER='[EMPTY]', DESC='S013037_BCN1 2 STACK IOLINK BEACON', TERM='IO08'
|
|
Row 507: TAGNAME='VS01C_FIOM9', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO09'
|
|
Row 508: TAGNAME='VS01C_FIOM9', PARTNUMBER='[EMPTY]', DESC='S013039_BCN1 2 STACK IOLINK BEACON', TERM='IO10'
|
|
Row 509: TAGNAME='VS01C_FIOM9', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO11'
|
|
Row 510: TAGNAME='VS01C_FIOM9', PARTNUMBER='[EMPTY]', DESC='VS01C_FIOH9 FIO HUB', TERM='IO12'
|
|
Row 511: TAGNAME='VS01C_FIOM9', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO13'
|
|
Row 512: TAGNAME='VS01C_FIOM9', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO14'
|
|
Row 513: TAGNAME='VS01C_FIOM9', PARTNUMBER='[EMPTY]', DESC='SPARE', TERM='IO15'
|
|
Created 32 FIOH modules based on TERM analysis
|
|
Found 31 IOLM modules
|
|
Found 2 DPM modules
|
|
WARNING: 32 unknown modules found
|
|
1. VS01B_FIOM1 - ()
|
|
2. VS01B_FIOM10 - ()
|
|
3. VS01B_FIOM11 - ()
|
|
4. VS01B_FIOM12 - ()
|
|
5. VS01B_FIOM13 - ()
|
|
6. VS01B_FIOM14 - ()
|
|
7. VS01B_FIOM15 - ()
|
|
8. VS01B_FIOM16 - ()
|
|
9. VS01B_FIOM17 - ()
|
|
10. VS01B_FIOM2 - ()
|
|
11. VS01B_FIOM3 - ()
|
|
12. VS01B_FIOM4 - ()
|
|
13. VS01B_FIOM5 - ()
|
|
14. VS01B_FIOM6 - ()
|
|
15. VS01B_FIOM7 - ()
|
|
16. VS01B_FIOM8 - ()
|
|
17. VS01C_FIOM1 - ()
|
|
18. VS01C_FIOM10 - ()
|
|
19. VS01C_FIOM11 - ()
|
|
20. VS01C_FIOM12 - ()
|
|
21. VS01C_FIOM13 - ()
|
|
22. VS01C_FIOM14 - ()
|
|
23. VS01C_FIOM15 - ()
|
|
24. VS01C_FIOM16 - ()
|
|
25. VS01C_FIOM2 - ()
|
|
26. VS01C_FIOM3 - ()
|
|
27. VS01C_FIOM4 - ()
|
|
28. VS01C_FIOM5 - ()
|
|
29. VS01C_FIOM6 - ()
|
|
30. VS01C_FIOM7 - ()
|
|
31. VS01C_FIOM8 - ()
|
|
32. VS01C_FIOM9 - ()
|
|
Created 31 IOLM modules with boilerplate selection:
|
|
Device 'DPM1_VS01B_FIOM1' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01B_FIOM1 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01B_FIOM10' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01B_FIOM10 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01B_FIOM11' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01B_FIOM11 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01B_FIOM12' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01B_FIOM12 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01B_FIOM13' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01B_FIOM13 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01B_FIOM14' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01B_FIOM14 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01B_FIOM15' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01B_FIOM15 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01B_FIOM16' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01B_FIOM16 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01B_FIOM2' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01B_FIOM2 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01B_FIOM3' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01B_FIOM3 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01B_FIOM4' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01B_FIOM4 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01B_FIOM5' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01B_FIOM5 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01B_FIOM6' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01B_FIOM6 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01B_FIOM7' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01B_FIOM7 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01B_FIOM8' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01B_FIOM8 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01B_FIOM9' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01B_FIOM9 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01C_FIOM1' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01C_FIOM1 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01C_FIOM10' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01C_FIOM10 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01C_FIOM11' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01C_FIOM11 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01C_FIOM12' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01C_FIOM12 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01C_FIOM13' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01C_FIOM13 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01C_FIOM14' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01C_FIOM14 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01C_FIOM15' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01C_FIOM15 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01C_FIOM2' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01C_FIOM2 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01C_FIOM3' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01C_FIOM3 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01C_FIOM4' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01C_FIOM4 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01C_FIOM5' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01C_FIOM5 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01C_FIOM6' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01C_FIOM6 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01C_FIOM7' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01C_FIOM7 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01C_FIOM8' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01C_FIOM8 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Device 'DPM1_VS01C_FIOM9' matched pattern 'VS', assigned to: SLOT2_EN4TR (Slot 2, IP 11.200.1.1)
|
|
DPM1_VS01C_FIOM9 (FIO D2CMaster): Using variant boilerplate D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/D2CMaster_Module.L5X
|
|
VS01B_FIOH1 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01B_FIOH10 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01B_FIOH11 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01B_FIOH12 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01B_FIOH13 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01B_FIOH14 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01B_FIOH15 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01B_FIOH16 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01B_FIOH17 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01B_FIOH2 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01B_FIOH3 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01B_FIOH4 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01B_FIOH5 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01B_FIOH6 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01B_FIOH7 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01B_FIOH8 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01C_FIOH1 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01C_FIOH10 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01C_FIOH11 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01C_FIOH12 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01C_FIOH13 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01C_FIOH14 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01C_FIOH15 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01C_FIOH16 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01C_FIOH2 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01C_FIOH3 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01C_FIOH4 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01C_FIOH5 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01C_FIOH6 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01C_FIOH7 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01C_FIOH8 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
VS01C_FIOH9 (FIOH Sorter): Using variant boilerplate Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/Sorter_FIOH_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/SLOT5_IB16_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/SLOT7_IB16S_Module.L5X
|
|
Successfully loaded boilerplate: SAT9_boilerplate/SLOT6_OB16E_Module.L5X
|
|
No EN4TR modules registered for creation
|
|
WARNING: MCM base L5X not found at SAT9_boilerplate/MCM05.L5X
|
|
Using fallback: /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/IO Tree Configuration Generator/BaseProgram.L5X
|
|
Archived old L5X: SAT9_MCM05_20250904_201807.L5X
|
|
Programs already exist (2 programs found), skipping empty program creation
|
|
OK: Generated project: /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/generated_projects/SAT9_MCM05/SAT9_MCM05_20250904_202032.L5X
|
|
Single file generation complete
|
|
- ['/mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/generated_projects/SAT9_MCM05/SAT9_MCM05_20250904_202032.L5X']
|
|
|
|
=== Step 3 Batch Script Creation ===
|
|
Creating project folder compilation for: SAT9_MCM05
|
|
Source L5X: /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/generated_projects/SAT9_MCM05/SAT9_MCM05_20250904_202032.L5X
|
|
Project directory: /mnt/c/Users/ilia.gurielidze/Projects/PLC Generation/generated_projects/SAT9_MCM05
|
|
Generated batch file: compile_SAT9_MCM05.bat
|
|
SUCCESS: Project compilation ready!
|
|
To compile on Windows:
|
|
cd "C:\\Users\\ilia.gurielidze\\Projects\\PLC Generation\\generated_projects\\SAT9_MCM05"
|
|
compile_SAT9_MCM05.bat
|
|
|